Cálculo de Coeficientes de Fluência de Nêutrons para Equivalente de Dose Individual Utilizando o Geant4
DOI:
https://doi.org/10.15392/bjrs.v3i1A.73Keywords:
Geant4, nêutrons, dosimetriaAbstract
Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo Geant4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, Hp (10)/ϕ, with Geant4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm3, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm2). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo Geant4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly.
Downloads
References
LEUTHOLD G.; MARES V.; SCHRAUBE, H., Calculation of the neutron ambient dose equivalent on the basis of the ICRP revised quality factors, Radiation Protection Dosimetry, v. 40. n 2, p. 77-84 , 1992.
ICRU - International Commission on Radiation Units and Measurements. Measurement of dose equivalents from external photon and electron radiations. ICRU Report 47, Bethesda: ICRU , 1992a.
ICRP - International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103, Ann: ICRP 37 (2-4), 2007.
ICRU - International Commission on Radiation Units and Measurements. Determination of dose equivalents resulting from external radiation sources. ICRU Report 39, Bethesda: ICRU, 1985.
A General Monte Carlo N-Particle (MCNP) Transport Code. Available at: <http://mcnp.lanl.gov/> (2013). Last accessed: 10 Jul. 2014.
National Research Council Canada. EGSnrc: software tool to model radiation transport, Available at: <http://www.nrc-cnrc.gc.ca/eng/solutions/advisory/egsnrc_index.html> (2013). Last accessed: 10 Jul. 2014.
PENELOPE 2011, A Code System for Monte-Carlo Simulation of Electron and Photon Transport, Available at: <http://www.oecd-nea.org/tools/abstract/detail/nea-1525> (2013). Last accessed: 10 Jul. 2014
“GEANT4: A toolkit for the simulation of the passage of particles through matter”, http://geant4.cern.ch/ (2013). Last accessed: 10 Jul. 2014
SCHUHMACHER H.; SIEBERT B. R. L. Quality factors and ambient dose equivalent for neutrons based on the new ICRP recommendations, Radiation Protection Dosimetry, v. 40. n 2, p. 85-89,1992.
SIEBERT B. R. L.; SCHUHMACHER H. Quality factors, ambient and personal dose equivalent for neutrons, based on the new ICRU stopping power data for protons and alpha particles. Radiation Protection Dosimetry, v. 58, n 3, p. 177-183, 1995.
ICRP - International Commission on Radiological Protection. Conversion Coefficients for use in Radiological Protection against External Radiation, ICRP Publication 74. Ann: ICRP 26 (3-4), 1996.
AGOSTINELLI S. ET AL., GEANT4 - a simulation toolkit. Nuclear Instruments and Methods in Physics Research”, Elsevier Science, v. 506, p. 250-303, 2003.
ICRU - International Commission on Radiation Units and Measurements. Conversion coefficients for use in radiological protection against external radiation. ICRU Report 57, Bethesda: ICRU, 1998.
GARNY S., ET AL., GEANT4 Transport Calculations for Neutrons and Photons below 15 MeV”, IEEE Transactions On Nuclear Science, v. 56, n 4, p. 2392-2396, 2009.
ICRU - International Commission on Radiation Units and Measurements, Stopping Powers and Ranges for Protons and Alpha Particles, ICRU Report 49, Bethesda: ICRU, 1993.
ICRU - International Commission on Radiation Units and Measurements, Stopping of Ions Heavier Than Helium, ICRU Report 73, Bethesda: ICRU, 2005.
ICRP - International Commission on Radiological Protection, 1990 Recommendations of the International Commission on Radiological Protection”, ICRP Publication 60. Ann: ICRP 21 (1-3), 1991.
CIRRONE G. A. P. ET AL. A Goodness-of-fit Statistical Toolkit, IEEE Transactions On Nuclear Science, v. 51, n 5. p. 2056-2063, 2004.
DARLING D. A., The Kolmogorov-Smirnov, Cramer-von Mises tests. Ann. Math. Statist, v. 28, p. 823-838, 1957.
GARNY S., Development of biophysical treatment planning system for the FRM II neutron therapy beamline, 189 f. Tese (Doutorado) – Universidade Técnica de Munique (TUM), Munique (2009).
Downloads
Published
Issue
Section
Categories
License
Copyright (c) 2015 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/