Evaluation of the performance of radiological monitors in use, cities Salvador (BA) and Florianópolis (SC)
DOI:
https://doi.org/10.15392/bjrs.v7i3.882Palabras clave:
Evaluation, performance, diagnostics monitors.Resumen
Evaluate the performance of the monitors used for diagnosis based on the parameters defined by AAMP. Materials and Methods: Using calibrated instrumentation traceable to NIST and RBC, were evaluated in 15 monitors, according to the procedures described in AAMP's report 03 and the Spanish protocol in the following parameters: the general aspects of image quality, geometric distortion, screen reflection and room illumination, luminance response, luminance dependence, spatial and low contrast resolution, noise, internal reflection blanking and screen chromaticity. Results: 100% compliance for geometric distortion tests and 0% compliance for the luminance dependence test. Conclusions: There are nonspecific monitors for diagnosis being used for these purposes, without routinely checking tests, in rooms with high illumination and dirt on the screens and the non-implementation or inadequacy of acceptance and quality control tests. The monitors declared by the manufacturers as diagnostic specific on average showed a higher compliance rateDescargas
Referencias
AAPM - American Association of Physicists in Medicine. Report 03 - Assessmente of display perfomance for medical imaging systems. 2005;4095:155. Avaliable at: <https://www.aapm.org/pubs/reports/or_03.pdf>. Last accessed:11 Feb. 2019.
SEFM, SEPR, SERAM. Protocolo Español De Control De Calidad En Radiodiagnóstico. 2011;77–132. Avaliable at: <https://www.sergas.es/Saude-publica/Documents/2958/Protocolo%20espanol-version%201.pdf>. Last accessed:11 Feb. 2019.
Ministério Da Saúde. PORTARIA Nº 2.898, DE 28 DE NOVEMBRO DE 2013. Brasil. Avaliable at: <http://bvsms.saude.gov.br/bvs/saudelegis/gm/2013/prt2898_28_11_2013.html>. Last accessed:11 Feb. 2019.
CFM – Conselho Federal de Medicina. RESOLUÇÃO CFM No 2.107/2014. Brasil. Avaliable at: <http://www.portalmedico.org.br/resolucoes/CFM/2014/2107_2014.pdf>. Last accessed:11 Feb. 2019.
SAUNDERS RS, SAMEI E. Resolution and noise measurements of five CRT and LCD medical displays. Med Phys. 2006;33(2):308–19.
RIBEIRO LD, APARECIDA T, FURQUIM C. Estudo do desempenho de display devicees LCD utilizados em radiologia digital. 2010;32:7–12 Avaliable at: <http://spr.org.br/wp-content/uploads/estudo-dos-display devicees-lcd.pdf>. Last accessed:11 Feb. 2019.
GARCIA, I.F.M. AVALIAÇÃO DO DESEMPENHO DOS DISPLAY DEVICEES USADOS PARA DIAGNÓSTICO. Dissertação (Mestrado em Tecnologias em Saúde) Escola Bahiana de Medicina e Saude Publica. Salvador. p.105.2016. Avaliable at: <https://www.repositorio.bahiana.edu.br:8443/jspui/handle/bahiana/782/statistics>. Last accessed:11 Feb. 2019.
MEDEIROS RB, ALVES FFR, RUBERTI FILHA EM, FINGERMAN F, PADOVAN AH, ELIAS S, et al. Influência da luminância do negatoscópio na detectabilidade de fibras e microcalcificações, determinada por meio de objetos simulados. Radiol Bras. 2003;36(1):21–5
Board of the Faculty of Clinical Radiology. Picture archiving and communication systems (PACS) and quality assurance Second edition. 2012. Avaliable at:
<https://www.rcr.ac.uk/sites/default/files/docs/radiology/pdf/BFCR(12)15_PACS_QA.pdf> .Last accessed:11 Feb. 2019.
AAPM - American Association of Physicists in Medicine. Report NO. 270 - Display Quality Assurance. 2019;85-9 <https://www.aapm.org/pubs/reports/RPT_270.pdf> Last accessed:11 Feb. 2019.
Descargas
Publicado
Número
Sección
Licencia
Derechos de autor 2019 Brazilian Journal of Radiation Sciences (BJRS)

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/