Algorithm to assess neutron HP(10) with estimation of uncertainties using Alnor albedo dosemeters: application in Brazilian nuclear power plants
DOI:
https://doi.org/10.15392/bjrs.v10i1.1769Palavras-chave:
neutron and photon HP(10), uncertainty, Angra PWRResumo
The Instituto de Radioproteção e Dosimetria (IRD) is implementing an automatic neutron individual monitoring system, which uses albedo dosemeters from the Alnor manufacturer. For practical purposes, the occupational neutron fields have been divided into four application areas, named N1, N2, N3 and N4, as recommended in the German standard DIN 6802-4. For each area, specific Workplace Correction Factor (WCF), as a function of the ratio between photon dose responses measured in the incident and albedo component of the albedo dosemeter (Di/Da), must be used. This study proposes an algorithm for evaluating the photons and neutrons HP(10) values for the Alnor albedo system. It uses WCF × Di/Da curves previously defined by the authors, using MCNPX code simulations of the neutron dosemeter response for several occupational neutron fields. The methodology for calculating all uncertainties involved in the photon and neutron HP(10) assessment is also shown. Before the routine use of this system at IRD, several tests and calibrations are being carried out. This manuscript presents a case study carried out at the Angra I and Angra II power plants in 14 different fields (N1 application area). The results of the Alnor system are compared with those from the albedo system currently in routine use at the IRD. The average value of the ratio between the measurements with the Alnor system and the IRD system was 0.97 for photon HP(10), and 0.84 for neutron HP(10). Considering an expanded uncertainty to 95% confidence level, all results agree with each other.
Downloads
Referências
MARTINS, M. M.; MAURICIO, C. L. P.; FONSECA, E. S.; DA SILVA, A. X. Brazilian two-component TLD albedo neutron individual monitoring system, Radiat. Meas., v. 45, pp. 1509 1512, 2010.
PIESCH, E.; BURGKHARDT, B. Erprobung eines Albedoneutronendosimetriesystems: TLD Kalibrier- und Meßverfahren, Neutronenkalibrierung, dosimetrische Eigenschaften, Routineanwendung, KfK 4303, Kernforschungszentrum Karlsruhe, Hauptabteilung Sicherheit, 1988.
PIESCH, E., BURGKHARDT, B.; UGI S. The Karlsruhe TLD Service for Albedo Neutron Dosimetry. In: Oberhofer, M. and Scharmann, A. Techniques and Management of Personnel Thermoluminescence Dosimetry Services, Euro Courses. Kluwer Academic Publishers for the Commission of the European Communities, 1993.
DIN - Deutsches Institut für Normung. Neutron dosimetry – Part 4: measurement technique for individual dosimetry using albedo dosemeters. DIN 6802-4, German text. Beuth Verlag, 1998.
FERREIRA, M. S.; Silva, E. R.; Maurício, C. L. P. Assessment of neutron Hp(10) using workplace correction factors obtained through Monte Carlo simulation for alnor albedo dosemeter. Manuscript submitted for publication, 2021.
LUSZIK-BHADRA, M. et al. Albedo neutron dosimetry in Germany: regulations and per-formance. Radiat. Prot. Dosim. 162, 649-656, 2014.
INMETRO – Instituto Nacional de Metrologia. Avaliação de dados de medição: Guia para a expressão de incerteza de medição – GUM2008, JCGM 100:2008, 2008.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2022 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/