Avaliação da Qualidade e Quantidade de Exames Tomográficos que Podem ser Realizados em Equipamentos Híbridos Existentes no Serviço de Medicina Nuclear da Faculdade de Medicina de Botucatu

Autores

  • Sérgio Augusto Santana de Souza Sao Paulo State University, Julio de Mesquita Filho, Institute of Biosciences, 18618687, Botucatu, São Paulo, Brazil. ,
  • Felipe Monteiro Rodrigues Sao Paulo State University, Julio de Mesquita Filho, Botucatu Medical School, 18618687, Botucatu, São Paulo, Brazil. ,
  • Allan Felipe Fattori Alves Botucatu Medical School, Clinics Hospital, Medical Physics, and Radioprotection Nucleus, 18618687, Botucatu, São Paulo, Brazil. ,
  • Matheus Alvarez Botucatu Medical School, Clinics Hospital, Medical Physics, and Radioprotection Nucleus, 18618687, Botucatu, São Paulo, Brazil. ,
  • Daniel Molena Seraphim Botucatu Medical School, Clinics Hospital, Medical Physics, and Radioprotection Nucleus, 18618687, Botucatu, São Paulo, Brazil. ,
  • Raul Lopes Ruiz Junior Sao Paulo State University Julio de Mesquita Filho, Botucatu Medical school, Department of Surgery and Orthopedics, 18618687, Botucatu, São Paulo, Brazil. ,
  • José Carlos Souza Trindade Filho Sao Paulo State University Julio de Mesquita Filho, Botucatu Medical school, Department of Urology, 18618687, Botucatu, São Paulo, Brazil. ,
  • Sergio Marrone Ribeiro Sao Paulo State University Julio de Mesquita Filho, Botucatu Medical school, Department of Tropical Diseases and Imaging Diagnosis, 18618687, Botucatu, São Paulo, Brazil. ,
  • Diana Rodrigues Pina , Faculdade de Medicina de Botucatu https://orcid.org/0000-0003-1967-1990 (não autenticado)

DOI:

https://doi.org/10.15392/bjrs.v10i2.1799

Palavras-chave:

Computed Tomography, Nuclear Medicine, Hybrid Equipment, Image Quality Assessment

Resumo

A Tomografia Computadorizada (TC) tem sido uma das maiores inovações para o diagnóstico médico. Entre as principais características da TC está a capacidade de fornecer imagens anatômicas e funcionais de alta qualidade. Outras modalidades de imagem importantes são as realizadas em Medicina Nuclear (MN), que, com o uso de radiotraçadores, possibilita a obtenção de imagens metabólicas e moleculares in vivo. A união das modalidades de imagem MN e TC é possível por meio de equipamentos híbridos. O objetivo desta pesquisa é avaliar a qualidade e a quantidade de exames tomográficos que podem ser realizados em equipamentos híbridos. Para completar esta pesquisa, foram realizadas análises da capacidade de realizar exames de TC na sala que contém um equipamento de Tomografia Computadorizada por Emissão de Fóton Único / Tomografia Computadorizada SPECT / CT em uma instalação de MN. Os critérios de avaliação foram: controle de qualidade dos equipamentos, avaliação da qualidade da imagem por método subjetivo de acordo com as Diretrizes Européias sobre Critérios de Qualidade para Tomografia Computadorizada (EUR) e avaliação da blindagem da sala, como indicador de quantos exames podem ser realizados. Considerando os resultados da espessura da barreira, o ambulatório da Faculdade de Medicina e o setor de Medicina Nuclear de Botucatu tem capacidade para realizar 100 exames de tomografia por semana. De acordo com informações obtidas no serviço, atualmente são realizados cerca de 20 exames semanais, portanto, há uma oportunidade maior de até 80 exames semanais. Portanto, o equipamento híbrido está qualificado para realizar exames diagnósticos com qualidade de imagem superior, quando comparado aos realizados em equipamentos de tomografia computadorizada.

Downloads

Os dados de download ainda não estão disponíveis.

Referências

BACH‐GANSMO, Tore et al. SPECT/CT hybrid imaging; with which CT?. Contrast media & molecular imaging, v. 5, n. 4, p. 208-212, 2010.

DENNIS, Jennifer L.; GEMMELL, Alastair J.; NICOL, Alice J. Optimization of the CT com-ponent of SPECT-CT and establishment of local CT diagnostic reference levels for clinical prac-tice. Nuclear medicine communications, v. 39, n. 6, p. 493-499, 2018.

MATTSSON, Sören; SÖDERBERG, Marcus. Radiation dose management in CT, SPECT/CT and PET/CT techniques. Radiation protection dosimetry, v. 147, n. 1-2, p. 13-21, 2011.

WANG, Yuankai; LIU, Zhuang. CT scan optimization in SPECT/CT equipment of nuclear med-icine. Zhongguo yi Liao qi xie za zhi= Chinese Journal of Medical Instrumentation, v. 37, n. 4, p. 308-310, 2013.

HCFMB, Transparência 2020 covid. Available:< https://www.hcfmb.unesp.br/transparencia-covid19/ >. Accessed: April 7, 2021.

Comissão Nacional de Energia Nuclear. Requisitos de Radioproteção e Segurança para Servi-ços de Medicina Nuclear. CNEN-NN-3.05; 2013.

MINISTÉRIO DA SAÚDE. Requisitos sanitários para a organização e funcionamento de serviços de radiologia diagnóstica ou intervencionista. Resolução RDC nº 330/2019.

International Atomic Energy Agency. Quality Assurance Programme for Computed Tomogra-phy: Diagnostic and Therapy Applications. IAEA Human Health Series No. 19, 2012.

American Association of Physicists in Medicine. Acceptance testing and quality control of pho-tostimulable storage phosphor imaging systems, AAPM Report No. 93, Report of AAPM Task Group 10, AAPM. 2006.

MINISTÉRIO DA SAÚDE. AGÊNCIA NACIONAL DE VIGILÂNCIA SANITÁRIA. ALDRED, M. A. Radiodiagnóstico Médico: Segurança e Desempenho de Equipamentos. Brasíl-ia: Ministério da Saúde, 2005. (Resolução 1016/05).

American College of Radiology. Computed Tomography Quality Control Manual, Copyright 2017.

MENZEL, H. G. European Guidelines on Quality Criteria for Computed Tomography Europe-an Guidelines on Quality Criteria. Luxemb. Eur. Comm. Off. Publ. 1, 46–60 (1999).

PELEGRINO BASTOS MAUÉS, Nadine Helena et al. Abdomen–pelvis computed tomogra-phy protocol optimization: an image quality and dose assessment. Radiation protection dosimetry, v. 184, n. 1, p. 66-72, 2019.

JURIK, A. et al. Clinical use of image quality criteria in computed tomography: a pilot study. Radiation protection dosimetry, v. 90, n. 1-2, p. 47-52, 2000.

NATIONAL COMMITTEE ON RADIATION PROTECTION (US). Structural shielding design for medical x-ray imaging facilities. NCRP, 2004.

KUSANO, Maggie; CALDWELL, Curtis B. Dose equivalent rate constants and barrier trans-mission data for nuclear medicine facility dose calculations and shielding design. Health physics, v. 107, n. 1, p. 60-72, 2014.

MINISTÉRIO DA SAÚDE. Dispõe sobre requisitos sanitários para a garantia da qualida-de e da segurança em sistemas de tomografia computadorizada médica, e dá outras providên-cias. Brasília, 27 de Maio de 2021. (Instrução normativa n°93/2021).

Comissão Nacional de Energia Nuclear. Diretrizes Básicas de Radioproteção. CNEN-NN-3.01; 2005.

Publicado

13-06-2022

Edição

Seção

Artigos

Como Citar

Avaliação da Qualidade e Quantidade de Exames Tomográficos que Podem ser Realizados em Equipamentos Híbridos Existentes no Serviço de Medicina Nuclear da Faculdade de Medicina de Botucatu. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 10, n. 2, 2022. DOI: 10.15392/bjrs.v10i2.1799. Disponível em: https://bjrs.org.br/revista/index.php/REVISTA/article/view/1799. Acesso em: 17 jul. 2025.