Evaluation of a Direct Ion Storage dosimeter efficiency to measure dose during interventional cardiology procedures
DOI:
https://doi.org/10.15392/bjrs.v10i3.2072Palavras-chave:
dosimetry, direct ions storage, ionization chamber, Intraintracardiac electrophysiology, occupational doseResumo
Intracardiac electrophysiological invasive procedures guided by fluoroscopy aim to study the cardiac depolarization process. Depending on the complexity of the clinical case, both patients and professionals are subjected to radiation for a prolonged period. This work evaluated if a direct ions storage (DIS) dosimeter could measure occupational doses in different regions of the physician's body during these procedures. Doses were monitored close to the left eye (LE), right eye (RE), extremity (left ankle), and thorax, as well as the environmental dose, positioning the dosimeter in the center of the equipment gantry. These doses were evaluated in 31 procedures using 01 DIS dosimeter in each region. The Mann-Whitney U test demonstrated that the values obtained in the different regions represent different samples, while the Spearman test demonstrated that there is no evidence that there is a correlation between the data recorded in the different regions. DIS was effective in recording the doses in the LE region and the doses of dispersed radiation (Arc), with the values obtained: (30 quartile / maximum): LE (0.07 / 0.20 mSv); Arc (0.38 / 1.53 mSv). It was not possible to compare occupational doses between different regions of the physician's body, limiting its use as a complementary monitor in the control of occupational doses.
Downloads
Referências
SOUZA, C. D., ROSTELATO, M. E. C. M., ZEITUNI, C. A., MOURA, J. A., MOURA, E. S., FONSECA, K. and FEHER, A. Analysis of the necessary radioprotection procedures in manufacture of iodine-125 sources used in brachytherapy: A preliminary study. Progress in Nuclear Energy, v.53, p.66-72, 2011.
MUNOZ, B. N. S. Estudo de Monitoração das Doses do Médico nos Exames de Eletrofisiologia e Ablação Cardiaca Masters: Masters. Federal University of São Paulo 2021.
OGUZ, K. and YÜKSEL, M. DETERMINATION OF THE MINIMUM DETECTABLE DOSE AND THE EFFECT OF DIFFERENT FILTERS ON TLD-100H 260°C THERMOLUMINESCENCE PEAK, In: International Conference on Radiation Applications, 2020, Thessaloniki, Greece. Annals of International Conference on Radiation Applications.
MIRION. InstadoseTM, 2020. Available at: <https://www.mirion.com/services-consulting/instadose-dosimetry-services-x-ray-badges>. Last acessed: 22 may, 2020.
SOCIEDADE BRASILEIRA DE CARDIOLOGIA. Recomendações do Departamento de Arritmias e Eletrofisiologia Clínica (DAEC) da Sociedade Brasileira de Cardiologia para Indicações de Implante de Marcapasso Definitivo, Escolha do Modo de Estimulação e Indicações para Implante de Desfibrilador-Cardioversor Automático. Arq Bras Cardiol v.64, p.4, 1995.
SUN, Z., ABAZIZ, A. and YUSOF, A. K. Radiation-induced noncancer risks in interventional cardiology: optimisation of procedures and staff and patient dose reduction. Biomed Res Int, v.2013, p.976962, 2013.
BOR, D., CEKIRGE, S., TÜRKAY, T., TURAN, O., GÜLAY, M., ONAL, E. and CIL, B. Patient and staff doses in interventional neuroradiology. Radiat Prot Dosimetry, v.117, p.62-8, 2005.
FLETCHER, D. W., MILLER, D. L., BALTER, S. and TAYLOR, M. A. Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures. J Vasc Interv Radiol, v.13, p.391-7, 2002.
JACOB, S., MICHEL, M., SPAULDING, C., BOVEDA, S., BAR, O., BRÉZIN, A. P., STREHO, M., MACCIA, C., SCANFF, P., LAURIER, D. and BERNIER, M.-O. Occupational cataracts and lens opacities in interventional cardiology (O'CLOC study): are X-Rays involved? BMC Public Health, v.10, p.537, 2010.
CIRAJ-BJELAC, O., REHANI, M., MINAMOTO, A., SIM, K. H., LIEW, H. B. and VANO, E. Radiation-Induced Eye Lens Changes and Risk for Cataract in Interventional Cardiology. Cardiology, v.123, p.168-171, 2012.
VANO, E., KLEIMAN, N. J., DURAN, A., ROMANO-MILLER, M. and REHANI, M. M. Radiation-associated Lens Opacities in Catheterization Personnel: Results of a Survey and Direct Assessments. Journal of Vascular and Interventional Radiology, v.24, p.197-204, 2013.
CONSELHO NACIONAL DE SAÚDE. RESOLUÇÃO Nº 466, DE 12 DE DEZEMBRO DE 2012., http://conselho.saude.gov.br/resolucoes/2012/Reso466.pdf, 2012.
SECRETARIA DE VIGILÂNCIA SANITÁRIA. Diretrizes de Proteção Radiológica em Radiodiagnóstico Médico e Odontológico. Portaria 453 de 01-06-1998., https://www.phymed.com.br/fisica-medica/site/textos/portaria453.PDF, 1998.
RANA, V., RUDIN, S. and BEDNAREK, D. Updates in the real-time dose tracking system (DTS) to improve the accuracy in calculating the radiation dose to the patients skin during fluoroscopic procedures, SPIE, 2013.
INTERNATIONAL ELECTROTECHNICAL COMMISSION. Medical electrical equipment https://webstore.iec.ch/publication/2603, 2019.
NATIONAL COUNCIL ON RADIATION PROTECTION AND MEASUREMENTS. Report No. 168 – Radiation Dose Management for Fluoroscopically-Guided Interventional Medical Procedures National Council on Radiation Protection and Measurements. 2010.
HAGA, Y., CHIDA, K., KAGA, Y., SOTA, M., MEGURO, T. and ZUGUCHI, M. Occupational eye dose in interventional cardiology procedures. Sci Rep, v.7, p.569, 2017.
EINSTEIN, A. J., MOSER, K. W., THOMPSON, R. C., CERQUEIRA, M. D. and HENZLOVA, M. J. Radiation Dose to Patients From Cardiac Diagnostic Imaging. Circulation, v.116, p.1290-1305, 2007.
EFSTATHOPOULOS, E. P., KATRITSIS, D. G., KOTTOU, S., KALIVAS, N., TZANALARIDOU, E., GIAZITZOGLOU, E., KOROVESIS, S. and FAULKNER, K. Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysis. EP Europace, v.8, p.443-448, 2006.
TSAPAKI, V. Radiation dose in interventional cardiology. Imaging in Medicine, v.2, p.10, 2010.
VAÑÓ, E., GONZÁLEZ, L., BENEYTEZ, F. and MORENO, F. Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories. Br J Radiol, v.71, p.728-33, 1998.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2022 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/