Application of OSL strips in CT dosimetry according to the AAPM methodology
DOI:
https://doi.org/10.15392/2319-0612.2023.2259Palavras-chave:
dose profiles, OSL strips, equilibrium doses, AAPM methodologyResumo
Computed tomography (CT) images contribute to high-quality medical diagnosis, but radiation dose can be quite high, requiring accurate assessment. CT dose index (CTDI) was developed for dosimetric purposes, but for scanners operated exclusively in axial mode. Nowadays, CTDI underestimate patient dose in helical CT exams. AAPM report TG111 (2010) suggested a new metric in which the patient's radiation dose is obtained from dose profiles constructed from several measurements made with a small ionization chamber. It is also possible to obtain dose profiles using properly calibrated OSL (optically stimulated luminescence) strips. The main objective of the present work is to contribute to optimizing CT dosimetry, comparing dose profiles obtained with OSL strips with measurements obtained by other authors. In this work, a “pencil” ionization chamber and 20 cm x 0.3 cm OSL strips were X-ray-irradiated, in air and in the holes of two cylindrical CT phantoms, using 100, 120, 140 kV peak voltages, both in lab and in a clinical CT scanner. Irradiated strips were read using an OSL reader built in the GDRFM. OSL profiles were calibrated against ionization chamber. From them, CTDIw and CTDIvol values were determined, differing approximately 3.9% from those of the CT scanner. From the profiles, also the planar equilibrium dose Deq,p (TG111) was evaluated in some CT protocols; Deq,p exceeded the CTDI values from the CT scanner in every case. E.g.: The percentage difference between Deq,p and CTDIvol for the head phantom ranged between 33-25%. Thus, in some cases, it could be advantageous to use calibrated OSL dosimeters instead of ionization chambers to obtain the profiles, saving time, because it is possible to obtain five OSL profiles from a single phantom irradiation.
Downloads
Referências
HSIEH, J.; FLOHR, T. Computed tomography recent history and future perspectives. J. Med. Imaging. v. 8:052109, 2019. Available at https://doi.org/10.1117/1.jmi.8.5.052109. Last accessed: 15 May 2023.
BRAMBILLA, M.; VASSILEVA, J.; KUCHCINSKA, A.; REHANI, M.M. Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for action. Eur. Radiol. v. 30(5): 2493-2501, 2020. Available at https://doi.org/10.1007/s00330-019-06528-7 . Last accessed: 15 May 2023.
DEMB, J.; CHU, P.; NELSON, T. et al. Optimizing radiation doses for Computed Tomography across institutions: dose auditing and best practices. JAMA Intern Med. v. 177: 810–817, 2017. Available at https://doi.org/10.1001/jamainternmed.2017.0445 . Last accessed: 15 May 2023.
McCOLLOUGH, CH.; LENG, S.; YU L. et al. CT dose index and patient dose: they are not the same thing. Radiology v. 259(2): 311-316, 2011. Available at https://doi.org/10.1148%2Fradiol.11101800 . Last accessed: 15 May 2023.
BOONE, J. M. The trouble with CTDI 100. Medical Physics v. 34(4):1364–1371, 2007. Available at https://doi.org/10.1118/1.2713240 . Last accessed: 15 May 2023.
PERISINAKIS, K.; DAMILAKIS, J.; TZEDAKIS, A. et al. Determination of the weighted CT dose index in modern multi-detector CT scanners. Phys. Med. Biol. 52(21): 6485–6495, 2007. Available from http://dx.doi.org/10.1088/0031-9155/52/21/010 . Last accessed: 15 May 2023.
AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE (AAPM). Comprehensive methodology for the evaluation of radiation dose in X-ray computed tomography. AAPM report n. 111. Report of AAPM Task Group 111: The future of CT dosimetry. College Park, MD: AAPM, 2010. Available at https://www.aapm.org/pubs/reports/RPT_111.pdf . Last accessed: 15 May 2023.
AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE (AAPM). The design and use of the ICRU/AAPM CT radiation dosimetry phantom: an implementation of AAPM report 111. In: Bakalyar D.M., Angel E., Boedeker K.L., eds. The Report of AAPM Task Group 200. AAPM, 2020. Available at https://www.aapm.org/pubs/reports/RPT_200.pdf . Last accessed: 15 May 2023.
CAMPELO M.C.S.; SILVA M.C.; TERINI R.A. CTDI versus New AAPM Metrics to assess Doses in CT: a case study. Braz. J. Rad. Sci. v. 04-02:01-15, 2016. Available at https://doi.org/10.15392/bjrs.v4i2.194 . Last accessed: 15 May 2023.
RUAN, C.; YUKIHARA, EG.; CLOUSE, WJ. et al. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology. Med. Phys. v. 37(7): 3560-3568, 2010. Available at: https://doi.org/10.1118/1.3455285. Last accessed: 15 May 2023.
OLIVEIRA, J.D.; YOSHIMURA, E.M.; TERINI, R.A. Otimização na Avaliação de Doses em TC usando Dosímetros OSL em forma de Fita. (Optimization in Dose Assessment in CT using Tape-shaped OSL Dosimeters). Rev. Bras. Física Médica (online) v. 15, 615, 2021. Available at https://doi.org/10.29384/rbfm.2021.v15.19849001615 . Last accessed: 15 May 2023.
UMISEDO N.K.; YOSHIMURA E.M. POSLI – Instrumentation for reading tape-shaped OSL detectors. Grupo de Dosimetria das Radiações e Física Médica – Instituto de Física da Universidade de São Paulo, 2013.
LI, X.; ZHANG, D.; LIU, B. Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms. Med. Phys. v. 40, 081914, 2013. Available at https://doi.org/10.1118/1.4813899 . Last accessed: 15 May 2023.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2023 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/