Aspectos metrológicos na estimativa da atividade administrada em pacientes de medicina nuclear

Autores

  • Anelise Ruzzarin IRD , IRD
    • Ana Maria Xavier CNEN ,
      • akira Iwahara IRD ,
        • Luiz Tahuata IRD ,

          DOI:

          https://doi.org/10.15392/bjrs.v5i1.234

          Palavras-chave:

          nuclear medicine, radionuclide calibrator, activity

          Resumo

          In order to investigate the performance quality of routine measurements of Nuclear Medicine Services (NMS), the National Metrology Laboratory of Ionizing Radiation/Institute of Radiation Protection and Dosimetry (LNMRI/IRD) has been conducting, since 1998, a program of comparison for activity measurements of radiopharmaceuticals administered to patients in nuclear medicine. Correction factors are determined from the result of performance analysis in order to determine with better accuracy the activity to be administered to the patients.

          Downloads

          Os dados de download ainda não estão disponíveis.

          Referências

          AMERICAN COLLEGE OF RADIOLOGY. ACR–SPR Practice Guideline for the Performance of Renal Scintigraphy. Res. 51– 2013.

          CNEN-NN-3.05. COMISSÃO NACIONAL DE ENERGIA NUCLEAR. Requisitos de radioproteção e segurança para serviços de medicina nuclear. CNEN, 2013.

          Balon, H R et al. Society of Nuclear Medicine Procedure Guideline for Thyroid Scintigraphy. 2006;12: 1-4.

          CORREIA, A R. Fatores de Correção dos Calibradores de Radionuclídeos Comerciais para Várias Geometrias de Medição de Radiofármacos. Dissertação de Mestrado. Instituto de Radioproteção e Dosimetria. Rio de Janeiro. 2011.

          INTERNATIONAL ATOMIC ENERGY AGENCY. Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy. IAEA Publication 1113, 2001.

          DONOHOE K J et al. Society of Nuclear Medicine Procedure Guideline for Bone Scintigraphy. Nucl. Med. Technol. 2003;30(12): B99-B103.

          TAUHATA , L.; IWAHARA, A.; OLIVEIRA, A. E.; YACOVENCO , M.; REZENDE, E. A., DELGADO, J. U.; SILVA, C. J. DA, SANTOS, J. A., ALABARSE, F.; XAVIER,A.M. Proficiency tests in the determination of activity of radionuclides in radiopharmaceutical products measured by nuclear medicine services in 8 year of comparison programmes in Brazil. Applied Radiation and Isotopes. V.66, p.981 - 987, 2008.

          Downloads

          Publicado

          06-04-2017

          Edição

          Seção

          II Congresso Brasileiro de Metrologia das Radiações Ionizantes