Calibration of the LDI/CDTN Whole Body Counter us-ing two physical phantoms
DOI:
https://doi.org/10.15392/bjrs.v5i3.252Palavras-chave:
Internal Dosimetry, Whole Body Counter, BOMAB, Radioprotection.Resumo
The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs) at the Unit for Research and Production of Radiopharmaceuticals (UPPR/CDTN), the Research Reactor TRIGA-IPR-R1/CDTN and other workplaces of the institute where there is a risk of accidental intakes. Additionally, LDI supports the Institute of Radiation Protection and Dosimetry (IRD/CNEN) to attend radiological emergencies. The determination of photon emitting radionuclides in the human body requires the use of calibration techniques in different counting geometries for converting the count rates into activity in organs and tissues. This paper presents and discusses the calibration of the LDI/CDTN Whole Body Counter (WBC) using a standard BOMAB phantom (Bottle Mannequin Absorber) compared to a home-made phantom produced with Polyethylene Terephthalate bottles (PET). Initially, the BOMAB was filled with a cocktail containing 60Co, 137Cs and 133Ba. The phantom was counted at the LDI whole body counter and an Efficiency x Energy curve was obtained. Subsequently the PET-BOMAB was filled with the same standard source and a second curve was determined. The efficiency values in each region of interest as well as the shape of both curves were found to be equivalent. The results validate the use of the PET-BOMAB for the calibration of whole body geometry applied to the measurement of high energy radionuclides in the energy region evaluated in this work.
Downloads
Referências
ANSI, American National Standards Institute, 1999. Specifications for the Bottle Manikin Absorption Phantom, ANSI N13.35, NewYork.
CANBERRA. Genie2000 Gamma Acquisition & Analysis, Version 3.1. Canberra Industries Inc., 2006.
DANTAS, B. M. et al. Accreditation and training on internal dosimetry in a laboratory network in Brazil: an increasing demand. Radiation Protection Dosimetry. Rio de Janeiro, v. 144, n. 1-4, p. 124-129, 2011.
FONSECA, T. C. F.; BOGAERTS, R.; HUNT, J.; VANHAVERE, F. A. Methodology to develop computational phantoms with adjustable posture for WBC calibration. Phys. Med. Biol. v. 59(22), p. 6811-6825, 2014a.
FONSECA, T. C. F. et al. MaMP and FeMP: computational mesh phantoms applied for studying the variation of WBC efficiency using a NaI(Tl) detector. Journal of Radiological Protection, v. 34, n. 3, p. 529, 2014b.
INTERNATIONAL ATOMIC ENERGY AGENCY, Direct Methods for Measuring Radionuclides in the Human Body, Safety Series No. 114, IAEA, Vienna (1996).
IAEA, International Atomic Energy Agency, 2014. Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards. Part 3 No. GSR.
ICRP, International Commission on Radiological Protection, 1991. ICRP Publication 60: 1990 Recommendations of the International Commission on Radiological Protection (No.60). Elsevier Health Sciences.
KRAMER, G. H. The Canadian whole body counting intercomparison program: a summary report for 1989-1993. Health physics, v. 69, n. 4, p. 560-565, 1995.
PAIVA, F.G. et al. Improvement of the WBC calibration of the Internal Dosimetry Laboratory of the CDTN/CNEN using the physical phantom BOMAB and MCNPX code. Applied Radiation and Isotopes, 2015.
SANTOS, L.R.D. Monitoração in vivo-análise de incertezas. Doctoral dissertation, Universidade de São Paulo, 2012.
Downloads
Publicado
Edição
Seção
Licença
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/