Comparação da dose absorvida de dois protocolos de varredura tomográfica em exame de PET/CT
DOI:
https://doi.org/10.15392/bjrs.v6i2B.394Palavras-chave:
Dosimetry, Computed Tomography, PET/CTResumo
Positron emission tomography (PET) associated with computed tomography (CT) allows the fusion of functional and anatomical images. When compared with other diagnostic techniques PET/CT subjects the patients to higher radiation dose levels because two radiation modalities in a single exam are used. In this study, the absorbed doses were evaluated in 19 organs from the CT scan. Radiochromic filmstrips were correctly positioned into the Alderson anthropomorphic phantom, masculine version. For this evaluation two Whole-body CT scan protocols were compared, one protocol for generating images with lower resolution aiming only the anatomical mapping (1), and a second protocol with higher resolution images for diagnostic purposes (2). There was an increase of up to 600 % in the absorbed dose in the hypophysis and cervical spine when comparing the protocols, with an average increase of around 230 % in other organs. The CT organ dose in patients submitted to PET/CT scanning is higher in the protocol used for diagnosis. Considering the higher cost of PET/CT examination and its applications in the diagnosis of minor alterations, in some cases it is necessary that CT scan has diagnostic quality, not only for the anatomical mapping, even knowing the dose increase for the patient. In these cases, the argument for using a higher patient doses technique is based on the Principle of Justification. It is worth emphasizing the importance of a careful evaluation of the need to perform the exam using protocol (2) for all patients, but only in essential cases.
Downloads
Referências
CZERNIN, J.; SCHELBERT, H. PET/CT imaging: facts, opinions, hopes, and questions. Journal of Nuclear Medicine, v. 45, n. 1 suppl, p. 1S-3S, 2004.
BROWNELL, L. G. A History of Positron Imaging. Physics Research Laboratory Massachusetts General, Hospital Division of Radiological Sciences, Massachusetts Institute of Technology. 1999.
CABREJAS, M. L. Tomografia em Medicina Nuclear. Editora Argentina, Argentina, 1999.
BEYER T., TOWNSEND D.W., BRUN T., KINAHAN P.E., CHARRON M., RODDY R., et al. A combined PET/CT scanner for clinical oncology. J Nucl Med. 2000; 41(8):1369–79.
BRIX, G.; BEYER, T. PET/CT. Nuklearmedizin, v. 44, p. S51-7, 2005.
QUINN, Brian et al. Radiation dosimetry of 18F-FDG PET/CT: incorporating exam-specific parameters in dose estimates. BMC medical imaging, v. 16, n. 1, p. 41, 2016.
MOORE, S.C.; PARK, M.. PET and PET/CT physics, instrumentation, and artifacts. 2012.
CZERNIN, J.; ALLEN-AUERBACH, M.; SCHELBERT, H. R. Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006. Journal of Nuclear Medicine, v. 48, n. 1 suppl, p. 78S-88S, 2007.
HUANG, B.; LAW, M.M.W.; KHONG, P. Whole-body PET-CT scanning: Estimation of radiation dose and cancer risk. Radiology, v. 251, n. 1, p.166-174. 2009.
SANTANA, P.C. Doses e risco da radiação em pacientes submetidos a exames de corpo inteiro de 18F-FDG PET-CT para diagnóstico oncológico. 2014. 117f. Tese (Doutorado em Ciências e técnicas nucleares). Universidade Federal de Minas Gerais, 2014.
KAUSHIK, Aruna et al. Estimation of radiation dose to patients from 18FDG whole body PET/CT investigations using dynamic PET scan protocol. The Indian journal of medical research, v. 142, n. 6, p. 721, 2015.)
SOMERWIL, A.; VAN KLEFFENS, H. J. Experience with the Alderson Rando phantom. The British journal of radiology, v. 50, n. 592, p. 295-296, 1977
OLIVEIRA, Cássio Miri et al. Suggestion of a national diagnostic reference level for 18F-FDG/PET scans in adult cancer patients in Brazil. Radiologia Brasileira, v. 46, n. 5, p. 284-289, 2013.
ISP - International specialty products, 2010. Gafchromic XR catalogue. 8p.15.
GIADDUI, Tawfik et al. Characteristics of Gafchromic XRQA2 films for kV image dose measurement. Medical physics, v. 39, n. 2, p. 842-850, 2012.)
MOURÃO, A. P.; GONÇALVES JR, R. G.; ALONSO, T. C. Dose profile variation with pitch in head CT scans using gafchromic films. Recent Advances in Biomedical & Chemical Engineering and Materials Science, v. 1, p. 51-4, 2014.,
Abramoff M, Magelhaes P, Ram S: Image Processing with ImageJ. Biophotonics International. 2004, 11: 36-42.
ABRAMOFF, M. D.; MAGALHAES, P. J.; RAM, S. J. Image processing with ImageJ. Biophotonics Int. 11: 36–42. Google Scholar, 2004.
BERA, G. et al. Equivalent dose rate from patients after whole-body FDG-PET/CT. Médecine Nucléaire, 2017.
TSUKAMOTO, Eriko; OCHI, Shinji. PET/CT today: system and its impact on cancer diagnosis. Annals of nuclear medicine, v. 20, n. 4, p. 255, 2006.
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/