Interpolation methods for creating a scatter radiation exposure map
DOI:
https://doi.org/10.15392/bjrs.v7i2A.596Palavras-chave:
Radiation Scattering, Betatron, Radiation Exposure Control,Resumo
A well know way for best understanding of radiation scattering and radiation exposure rate during a procedure using ionizing radiation is to map exposure over the space around the source and sample. This map is done measuring exposure in points regularly spaced, it means, measurement will be placed in localization chosen by increasing a regular steps from a starting point, along the x, y and z axes or, in more efficient way, radial and angular coordinates. However, it is not always possible to maintain the accuracy of the steps throughout the entire space, or there will be regions of difficult access where the regularity of the steps will be impaired. In this work we use a high energy radiation source to simulate a common radiography setup and construct its exposure map. The arrangement of the points and the interpolation were used considering polar coordinates. Then with the same data, an interpolation using the Delaunay triangulation was made. The results show the advantages and disadvantages of each other besides the high coherence for the same data. To simulate the impossibility of regular points, the same procedures were performed in the absence of any point and compared. The results show a lower total variation when the map is calculated by triangulation. The computational and graphic treatment was performed with GNU OCTAVE software and its image processing package. The data were acquired from a bunker where a 6MeV betatron was used as a primary source.A well know way for best understanding of radiation scattering and radiation exposure rate during a procedure using ionizing radiation is to map exposure over the space around the source and sample. This map is done measuring exposure in points regularly spaced, it means, measurement will be placed in localization chosen by increasing a regular steps from a starting point, along the x, y and z axes or, in more efficient way, radial and angular coordinates. However, it is not always possible to maintain the accuracy of the steps throughout the entire space, or there will be regions of difficult access where the regularity of the steps will be impaired. In this work we use a high energy radiation source to simulate a common radiography setup and construct its exposure map. The arrangement of the points and the interpolation were used considering polar coordinates. Then with the same data, an interpolation using the Delaunay triangulation was made. The results show the advantages and disadvantages of each other besides the high coherence for the same data. To simulate the impossibility of regular points, the same procedures were performed in the absence of any point and compared. The results show a lower total variation when the map is calculated by triangulation. The computational and graphic treatment was performed with GNU OCTAVE software and its image processing package. The data were acquired from a bunker where a 6MeV betatron was used as a primary source.
Downloads
Referências
IAEA - International Atomic Energy Agency. Radiation protection and safety in industrial radiography. Viena: IAEA- Safety report series, 1999. 69p
Chiang, H. W.; LIU, Y. L.; CHEN, T.R. CHEN, C. L.; CHIANG, H. J.; CHAO, S.Y. Scattered radiation doses absorbed by technicians at different distances from X-ray exposure: Experiments on prosthesis. Bio-medical materials and engineering. V.26, p.S1641-S1650, 2015.
REHN, E. Modeling of scatter radiation during interventional X-ray procedure, Master thesis, Linkoping University, Linkoping, Sweden, 2015. 46p.
KUON, E.; DAHM, J.; EMPEN, K.; ROBINSON, D. M.; REUTER, G; WUCHERER, M. Identification of less-irradiating Tube angulations in invasive cardiology. Journal of the American College of Cardiology. v44, n.7, p.1420-8, 2004.
HAQQANI, O. P.; AGARWAL, P. K.; HALIN, N. M.; IAFRATI, M. D. Defining the Scatter cloud in the interventional suite. Journal of vascular surgery, v.58, n.5, p.1339-45, 2013.
ALONSO, J. A.; SHAW, D. S.; MAXWELL, A.; McGill, G. P.; Hart, G. P. Scattered radiation during fixation of hip fractures. Is Distance alone enough protection? Journal of Bone and Joint Surgery, v.28-B, n. 6, p.815-8, 2001.
ALDEWAINI, Z.; LANGER, E.; SCHABER, P.; DAVID, M.; KRETZ. D.; STEIL, V.; HESSER, J. Real-time, ray casting-based scatter dose estimation for c-arm x-ray system, Journal of Applied Clinical Medical Physics, v.18, p.144-53, 2017.
ASTRAHAN, M. A.; STREETER, O. E.; JOZSEF, G. Calculation of mean central dose in interstitial brachytherapy using Delaunay triangulation, Medical Physics, v.28, n.6, p.1016-23, 2001.
JOZSEF, G.; STREETER, O. E.; ASTRAHAN, M. A. The use of linear programming in optimization of HDR implant dose distributions, Medical Physics, v.30, n.5, p.751-60, 2003.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/