Analysis of the setup deviations generated in the 6D ExacTrac X-ray system for patients in hypofractionated intracranial radiosurgery treatments
DOI:
https://doi.org/10.15392/bjrs.v7i1.793Palavras-chave:
intracranial radiosurgery, IGRT, ExacTrac X-Ray system, PTV marginsResumo
The purpose of this study was to evaluate the use of the pre-treatment daily imaging system with the Brainlab ExacTrac X-Ray 6D for patients in hypofractionated intracranial treatments and radiosurgery procedures in order to quantify setups errors and review margins used by the institution in the current planning protocol. The deviations generated in the translational and rotational coordinates were given in terms of the mean values and their respective standard deviations. The random and systematic errors were determined through the Stroom and Wang relation and 36 patients treated with intracranial hypofractionated radiosurgery from August 2015 to October 2016 were evaluated. The prescribed dose was 25-30 Gy in 5 fractions for 30 patients and 12-18 Gy in a single fraction for 6 patients. The calculated margin for the planning target volume (PTV) from the deviations analyzed was 1.3mm, consistent with that adopted by the institution. When the correlation between the volume of the PTV, vector and its respective loss of coverage is evaluated and a tendency can be observed for smaller volumes to suffer greater losses in coverage when the isocenters were displaced with the resulting margins. We can suggest that for volumes smaller than 2.6 cm3, margins greater than 1 mm are required in order to guarantee the expected coverage of the PTV.
Downloads
Referências
ICRU - International Commission on Radiation Units and Measurements. Prescribing, Recording and Reporting Photon Beam Therapy (Supplement to ICRU Report 51). ICRU Report 62, Bethesda: ICRU, 1999. 47p.
NCS - Netherlands Commission on Radiation Dosimetry. Process Management and Quality Assurance for Intracranial Stereotactic Treatment. Report 25, Netherlands Commission on Radiation Dosimetry. October 2015. 141p.
HERK V. M., Semin Radiat Oncol. 2007;17:258–67.
DING GX, DUGGAN DM, COFFEY CW, et al. A study on adaptive IMRT treatment planning using kV cone-beam CT. Radiother Oncol. 2007;85:116–125.
PAWLOWSKI JM, YANG ES, MALCOLM AW, COFFEY CW, DING GX. Reduction of dose delivered to organs at risk in prostate cancer patients via image-guided radiation therapy. Int J Radiat Oncol Biol Phys. 2010;76:924–934.
JIN JY, YIN FF, TENN SE, MEDIN PM, SOLBERG TD. Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy. Med Dosim.2008 Summer; 33(2):124-34.
GEVAERT T.; VERELLEN D.; ENGELS B.; DEPUYDT T.; HEUNINCKX K.; TOURNEL K.; DUCHATEAU M.; REYNDERS T.; RIDDER M. IGRT - Clinical Evaluation of a Robotic 6-Degree of Freedom Treatment Couch for Frameless Radiosurgery. Int J Radiat Oncol Biol Phys. 2012;83(1): 467-74.
VERBAKEL WF, LAGERWAARD FJ, VERDUIN AJ, HEUKELOM S, SLOTMAN BJ, CUIJPERS JP.The accuracy of frameless
stereotactic intracranial radiosurgery. Radiotherapy and Oncology 97 (2010) 390–394.
JIN J., RYU S., ROCK J., FABER K., GATES M., LI S., MOVSAS B. Image-Guided Target Localization for Stereotactic Radiosurgery: Accuracy of 6D versus 3D Image Fusion. Basel Karger, v. 6, p. 50-59, 2006.
ICRU - International Commission on Radiation Units and Measurements. Prescribing, Recording, and Reporting Intensity-Modulated Photon-Beam Therapy (IMRT). ICRU Report 83, 2010. Available at: https://doi.org/10.1093/jicru/ndq002, Last accessed: August 2018.
BALTER JM, CHEN GTY, PELIZZARI CA, et al. On-line repositioning during treatment of the prostate: A study of potential limits and gains. Int J Radiat Oncol Biol Phys 1993;27:137–143.
HERK V. Errors and margins in radiotherapy. Semin Radiat Oncol., v.14 p.52-64, 2004.
INFUSINO E, TRODELLA L, RAMELLA S, D'ANGELILLO R, GRECO C, IURATO A, E. TRODELLA L, NACCA A, CORNACCHIONE P AND MAMELI A. Estimation of patient setup uncertainty using BrainLAB Exatrac X-Ray 6D system in image-guided radiotherapy. Journal of Applied Clinical Medical Physics, v. 16; 2015.
STROOM J. C., HEIJMEN B. J. M. Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiotherapy and Oncology, v.64; 2002.
Wang H1, Wang C1, Tung S1, Dimmitt AW2, Wong PF1, Edson MA2, Garden AS2, Rosenthal DI2, Fuller CD2, Gunn GB2, Takiar V2, Wang XA1, Luo D1,Yang JN1, Wong J1, Phan J2. Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck cancer. J Appl Clin Med Phys. V16; 2016.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/