Impacto da pureza dos filtros de alumínio no valor de Camada Semi-Redutora em radiologia convencional e mamografia
DOI:
https://doi.org/10.15392/bjrs.v3i2A.92Palavras-chave:
Radiology, mammography, dosimetry.Resumo
Half Value Layer (HVL) test is an important technical information in conventional radiology once it is the only test which allows us to quantify beam quality in a complete way. This work promotes a preliminary analysis of the impact of aluminum alloy composition in the determination of HVL value taking into account a realistic geometry. Deterministic calculations and Monte Carlo Method were applied in order to make the proposed analysis. Six aluminum alloys (99% pure) commercialized and pure aluminum were used as comparative basis for both methods. Experimental data were collected in conventional radiology, using tungsten target and aluminum filter for two peak tensions (66 kVp, 81 kVp), and in mammography, using three target filter combinations( molybdenum-molybdenum, molybdenum-rhodium, tungsten-rhodium) for three peak tensions (25 kVp, 30 kVp and 35 kVp). Spectra used in the deterministic calculations were taken from Report No 78 of Institute of Physics and Engineering in Medicine, 1997. Results show that Mammography is more sensitive than conventional X-ray equipment to impurities in aluminum alloys (up to 34.65% variation for W-Rh combination with 30 kVp).
Downloads
Referências
AGOSTINELLI, S. et al. GEANT 4 — a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v 506, Issue 3, p.250-303. 2003.
ALLISON, J. et al. Geant Developments and Applications. IEEE Transactions on Nuclear Science, v.53, p. 270-278, 2006.
ANVISA – Agência Nacional de Vigilância Sanitária – Ministério da Saúde – Secretaria de Vigilância Sanitária. Diretrizes de ProteçãoRadiológicaemRadiodiagnóstico Medico e odontológico. ANVISA Portaria 453.1998.
ATTIX, F. H. Introduction to Radiological Physics and Radiation Dosimetry. New York: J. Wiley;1986.
CRANLEY, K. et al. Catalogue of Diagnosis X ray Spectra and Other Data. Report 78 The Institute of Physics and Engineering in Medicine - Report 78. 1997
FREE SOFTWARE FOUNDATION. Gnumeric. Disponível em: http://www.gnumeric.org/. GNU GPL Protect. Últimoacesso: 03 de Fevereiro de 2015.
LOPES, G. A. et al. Determinação de Camada Semi-Redutora e Deci-Redutora para Barita com blindagem contra radiação X em Proteção Radiológica. International Nuclear Atlantic Conference . Recife, 2013.
NAGEL, H. D. Limitations in the determination of the total filtration of x-ray tube assemblies. Phys Med Biol, v.33. p. 271-28, 1988.
BERGER, M. J. at al XCOM: Photon Cross Sections Database. Disponível em http://physics.nist.gov/PhysRefData/Xcom/html/xcom1.html. The NationalInstituteof Standards and Technology (NIST) isanagencyofthe U.S. DepartmentofCommerce. Último Acesso: 09 de setembro de 12014. .
VILLAFANA, T. Generators, x-ray tubes, and exposure geometry in mammography. Radiographics, v.10, p.539-54,1990.
WAGNER, L. K.; ARCHER, B. R.; CERRA, F. On the measurement of half-value layer in film-screen mammography. Med Phys, v.17, p.989-97, 1990.
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2016 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/