Image quality in chest tomography employing three different equipment technologies
DOI:
https://doi.org/10.15392/bjrs.v9i3.1680Palabras clave:
Computed tomography, chest, diagnostic imaging, image qualityResumen
Computed tomography represents the largest portion of the population´s exposure to ionizing radiation related to medical imaging. This article aims to assess the quality of the images through the analysis of radiologists in routine chest protocols, performed at one hospital and two diagnostic imaging clinics, and employing three equipment with different technologies. A total of 1,088 criteria were analyzed with the three imaging techniques, and the average percentage of the observed structures were 95, 99 and 99% for each service. There was an excellent correlation between observers and even an absolute agreement in some cases for the most modern technologies. The three studied devices provided acceptable dose values and images with a quality close to 100%, reducing the exposure and improving the radiological protection of patients.
Descargas
Referencias
PINA, et al. Criação de um indicador eletrônico para acompanhamento de dose no setor de Tomografia Computadorizada. Brazilian Journal of Radiation Sciences. Braz. J. Rad. Sci. 2020. 08-03 (2020) 01-14.
AIEA. TSA -3 Protección radiológica en lãs Exposiciones Médicas RLA 9057 / RLA 9067. Programa Regional Del OIEA para América Latina, 2007- 2013.
KUBO, T. et al. Standard-dose vs. low-dose CT protocols in the evaluation of localized lung lesions: Capability for lesion characterization—iLEAD study. European Journal of Radiology Open. [2016 a] 67–73. Disponível em: https://www.ejropen.com/article/S2352-0477(16)30007-7/pdf. Acesso: mar. 2019.
KUBO, T. et al. Low dose chest CT protocol [50 mAs] as a routine protocol for comprehensive assessment of intrathoracic abnormality. European Journal of Radiology Open Volume 3 [2016 b] 86–94. Disponível em: https://www.ejropen.com/action/showPdf?pii=S2352-0477%2816%2930009-0. Acesso: abr. 2019.
SOUZA, G. S.; FRONER, A.P.P.; SILVA, A.M.M.; Doses em tomografia computadorizada de crânio: impacto do uso do controle automático de exposição. Revista Brasileira de Física Médica. 2017; 11[2]:21-24
ZAMPIERI, J.F.; PACINI, G.S.; ZANON M.; et al. Calcificações torácicas na ressonância magnética: correlação com a tomografia computadorizada. J Bras Pneumol.;45[4]: 2019e20180168.
ICRU - International Commission on Radiation Units and Measurements. Radiation Dose and Image-Quality Assessment in Computed Tomography, ICRU Report 87, Journal of the ICRU, v. 12, No 1, 2012. Report. 87. Disponível em: https://icru.org/content/reports/radiation-dosimetry-and-image-quality-assessment-in-computed-tomography-icru-87. Acesso: mar.2019.
SOUZA, G.S.; FRONER, A.P.P.; SILVA, A.M.M.; Levantamento de Doses em Tomografia Computadorizada em Protocolos de Crânio e Tórax. Revista Brasileira de Física Médica. 2016;10[3]:34-38.
TORRES, P.P.T.S.; RABAHI, M.F.; MOREIRA, M.A.C.; et al. Avaliação tomográfica das doenças fúngicas no tórax: abordagem por padrões e sinais. Radiol Bras. 2018 Set/Out;51[5]:313–320. Disponível em: http://dx.doi.org/10.1590/0100-3984.2017.0223. Aces-so: mai 2020.
NOSCHANG, J.; GUIMARÃES, M.D.; TEIXEIRA D.F.D.; et al. Novas técnicas no diag-nóstico por imagem do tromboembolismo pulmonar. Radiol Bras. 2018 Mai/Jun;51[3]:178–186.
SODICKSON, A.; et al. Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risk from CT of Adults. Radiology. Boston. Volume 251: Number 1—April 2009. Disponível em: https://pubs.rsna.org/doi/pdf/10.1148/radiol.2511081296. Acesso: jan. 2019.
AAPM - American Association of Physicists in Medicine. The Measurement, Reporting, and Management of Radiation Dose in CT. College Park, MD. 2008. [AAPM Report. 96]. Disponível em: https://www.aapm.org/pubs/reports/RPT_96.pdf. Acesso: mar 2019.
DORNELES, C.M.; PACINI, G.S.; ZANON, M.; et al. Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases. J Pediatr [Rio J]. 2020; 96:92-9.
EUR - European Guidelines on Quality Criteria for Computed Tomography, Luxembourg. European Commissions’ Radiation Protection & the Office for Official Publications of the European Commission. 2004.
MINITAB. Suporte ao MINITAB 17. Disponível em: https://support.minitab.com/pt-br/minitab/19/. Acesso em: 01 jun. 2017.
MÓRAN, L.M.; RODRIGUEZ, R.; CALZADO, A. et al. Image quality and dose evaluation in spiral chest CT examinations of patients with lung carcinoma. The British Journal of Radiology, 77, 839–846 2004.
SOUZA, G.S.; LANFREDI, M.P.; SILVA, A.M.M.; Parâmetros de aquisição em tomografia computadorizada para pacientes pediátricos: uma revisão bibliográfica. Revista Brasileira de Física Médica. 2018;12[3]:30-34.
ALMEIDA, R.F.; et al. Padrões de tomografia computadorizada de alta resolução na doença pulmonar intersticial [DPI]: prevalência e prognóstico. J Bras Pneumol. 2020; 46 [5]: e20190153. Disponível em: htto:// dx.doi.org/10.36416/1806-3756/e20190153. Acesso em: 20 jun. 2020
BRITO, M.C.B.; OTA M.K.; LEITÃO FILHO, F.S.S.; et al. Concordância entre radiologistas na quantificação de bronquiectasias pela tomografia computadorizada de alta resolução. Radiol Bras. 2017 Jan/Fev;50[1]:26–31.
ANTUNES, V.B.; MEIRELLES, G.S.P.; JASINOWODOLINSKI, D.; et al. Concordância entre observadores no diagnóstico das doenças pulmonares intersticiais por imagens de TCAR. J Bras Pneumol. 2010;36[1]:29-36.
Descargas
Publicado
Número
Sección
Licencia
Derechos de autor 2021 Brazilian Journal of Radiation Sciences (BJRS)

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/