Response of a Commercial MOSFET to Clinical Photon and Electron Beams Used in Radiotherapy
DOI:
https://doi.org/10.15392/2319-0612.2026.2995Palabras clave:
Dosimetry, beam-on drain current, calibration beam, linear acceleratorResumen
One type of dosimeter used in radiotherapy is the metal-oxide-semiconductor field-effect transistor (MOSFET), which is widely employed in in vivo dosimetry. This study investigated the response of a commercial MOSFET (STQ2HNK60ZR-AP) to photon and electron beams from a clinical linear accelerator. Radiation damage is typically associated with the dose received by the device and is reflected in shifts in the transistor’s characteristic curve. In this work, however, a different approach was taken: the evaluated response was the beam-on drain current (ID), integrated during beam exposure. The ID under irradiation (IDX) was obtained by subtracting the ID measured without radiation, making the MOSFET functionally similar to an ionization chamber or diode detector. The transistor was placed between solid water plates in a 10 × 10 cm2 radiation field, with a source-to-surface distance of 100 cm. IDX was found to be directly proportional to the beam dose rate, and the collected charge showed minimal dependence on the dose rate (<3%). A Farmer ionization chamber was used as the reference detector. The MOSFET’s response was linear with dose, and the energy dependence for photon beams was approximately 7% between 15 MV and 6 MV. The calibration factor varied by around 6% across different energies and beam types. These results highlight the need for correction factors when using a beam other than the calibration beam to meet the uncertainty threshold recommended by the International Commission on Radiation Units and Measurements for radiotherapy (±5%). The findings are consistent with previously published results and support the suitability of the MOSFET for dosimetry of photon beams from clinical linear accelerators. Future work will focus on evaluating clinical dosimetry parameters, including percentage depth dose, output factor, and beam profile.
Descargas
Referencias
[1] KHAN, F. M. Clinical electron-beam dosimetry: report of AAPM Radiation Therapy Committee Task Group 25. Medical Physics, v. 18, p. 73-109, 1991. DOI: https://doi.org/10.1118/1.596695
[2] ICRU - INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS. Radiation Dosimetry: electrons with initial energies between 1 and 50 MeV. Bathesda: ICRU, 1972. (ICRU Report 21).
[3] ICRU - INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS. Dose Specification for Reporting External Beam Therapy with Photons and Electrons. Bathesda: ICRU, 1978. (ICRU Report 29).
[4] ICRU - INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS. Radiation Dosimetry: electron beams with energies between 1 and 50 MeV. Bathesda: ICRU, 1984. (ICRU Report 35).
[5] SANTOS, L. A. P. An overview on bipolar junction transistor as a sensor for x-ray beams used in medical diagnosis. Sensors, v. 22, p. 1-18, 2022. Disponível em: https://doi.org/10.3390/s22051923. DOI: https://doi.org/10.3390/s22051923
[6] MANIGANDAN, D. et al. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams. Physica Medica, v. 25, p. 141-147, 2009. Disponível em: https://doi.org/10.1016/j.ejmp.2008.11.003. DOI: https://doi.org/10.1016/j.ejmp.2008.11.003
[7] IAEA – INTERNATIONAL ATOMIC ENERGY AGENCY. TRS 483: dosimetry of small static fields used in external beam radiotherapy. Vienna: IAEA, 2017.
[8] MCGRATH, A. N.; GOLMAKANI, S.; WILLIAMS, T. J. Determination of correction factors in small MLC‐defined fields for the Razor and microSilicon diode detectors and evaluation of the suitability of the IAEA TRS‐483 protocol for multiple detectors. Journal of Applied Clinical Medical Physics, v. 23, n. 7, p. e13657, 2022. Disponível em: https://doi.org/10.1002/acm2.13657. DOI: https://doi.org/10.1002/acm2.13657
[9] AKINO, Y. et al. Characterization of a new commercial single crystal diamond detector for photon-and proton-beam dosimetry. Journal of Radiation Research, v. 56, n. 6, p. 912-918, 2015. Disponível em: https://doi.org/10.1093/jrr/rrv044. DOI: https://doi.org/10.1093/jrr/rrv044
[10] CARRASCO, P. et al. Characterization of the Exradin W1 scintillator for use in radiotherapy. Medical Physics, v. 42, p. 297–304, 2015. Disponível em: https://doi.org/10.1118/1.4903757. DOI: https://doi.org/10.1118/1.4903757
[11] PAPACONSTADOPOULOS, P.; TESSIER, F.; SEUNTJENS, J. On the correction, perturbation and modification of small field detectors in relative dosimetry. Physics in Medicine & Biology, v. 59, n. 19, p. 5937, 2014. Disponível em: https://doi.org/10.1088/0031-9155/59/19/5937. DOI: https://doi.org/10.1088/0031-9155/59/19/5937
[12] AKINO, Y. et al. Characterization of a microSilicon diode detector for small-field photon beam dosimetry. Journal of Radiation Research, v. 61, n. 3, p. 410–418, 2020. Disponível em: doi.org. DOI: https://doi.org/10.1093/jrr/rraa010
[13] CASAR, B. et al. A novel method for the determination of field output factors and output correction factors for small stactic fields for six diodes and a microdiamond detector in megavoltage photon beams. Medical Physics, v. 46, n. 2, p. 944-963, 2019. Disponível em: https://doi.org/10.1002/mp.13318. DOI: https://doi.org/10.1002/mp.13318
[14] AKINO, Y. et al. Characteristics of microSilicon diode detector for electron beam dosimetry. Journal of Radiation Research, v. 62, n. 6, p. 1130–1138, 2021. Disponível em: https://doi.org/10.1093/jrr/rrab085. DOI: https://doi.org/10.1093/jrr/rrab085
[15] HAIJUN, C. et al. Limitations of Silicon Diodes for clinical electron Dosimetry. Radiation Protection Dosimetry, v. 120, p. 56-59, 2006. Disponível em: doi.org. DOI: https://doi.org/10.1093/rpd/ncj007
[16] CAVALCANTI, F. A.; SANTOS, L. A. A MOSFET-based method for measuring peak kilovoltage (kVp) in Diagnostic X-Ray Beams. IEEE Open Journal of Instrumentation and Measurement, v. 1, p. 1-7, 2022. Disponível em: https://doi.org/10.1109/OJIM.2022.3196725. DOI: https://doi.org/10.1109/OJIM.2022.3196725
[17] KUMAR, A. S.; SHARMA, S. D.; RAVINDRAN, B. P. Characteristics of mobile MOSFET dosimetry system for megavoltage photon beams. Journal of Medical Physics, v. 39, n. 3, p. 142-149, 2014. Disponível em: https://doi.org/10.4103/0971-6203.139002. DOI: https://doi.org/10.4103/0971-6203.139002
[18] KALEF EZRA, J. A. et al. Thermoluminescence dosimetry for quality assurance in radiation therapy. Radiation Protection Dosimetry, v. 101, p. 403-405, 2002. Disponível em: https://doi.org/10.1093/oxfordjournals.rpd.a006011. DOI: https://doi.org/10.1093/oxfordjournals.rpd.a006011
[19] SOUBRA, M.; CYGLER, J.; MACKAY, G. Evaluation of a dual bias dual metal oxide silicon semiconductor field effect transistor detector as radiation dosimeter. Medical Physics, v. 21, p. 567-572, 1994. Disponível em: https://doi.org/10.1118/1.597314. DOI: https://doi.org/10.1118/1.597314
[20] AL MOHAMMED, H. I. Evaluation of clinical use of OneDose metal oxide semiconductor field effect transistor detectors compared to thermoluminescent dosimeters to measure skin dose for adult patients with acute lymphoblastic leukemia. North American Journal of Medical Sciences, v. 3, n. 8, p. 362, 2011. Disponível em: https://doi.org/10.4297/najms.2011.3362. DOI: https://doi.org/10.4297/najms.2011.3362
[21] XIANG, H. F. et al. Build up and surface dose measurements on phantoms using micro MOSFET in 6 and 10 MV x ray beams and comparisons with Monte Carlo calculations. Medical Physics, v. 34, n. 4, p. 1266-1273, 2007. Disponível em: https://doi.org/10.1118/1.2710951. DOI: https://doi.org/10.1118/1.2710951
[22] GONÇALVES FILHO, L. C. et al. Radiation dose response of n-channel MOSFET submitted to filtered X-ray photon beam. IEEE Transactions on Nuclear Science, v. 65, n. 9, p. 2607-2610, 2018. Disponível em: https://doi.org/10.1109/TNS.2018.2846668. DOI: https://doi.org/10.1109/TNS.2018.2846668
[23] CHEN, A. X. et al. Compact Ion Beam System for Fusion Demonstration. Physics Open, v. 21, p. 100234, 2024. Disponível em: https://doi.org/10.1016/j.physo.2024.100234. DOI: https://doi.org/10.1016/j.physo.2024.100234
[24] AL KHARUSI, O. et al. Commissioning and performance assessment of diodes and MOSFETs in in-vivo dosimetry for external beam radiation therapy. Radiation and Environmental Biophysics, p. 1-15, 2025. Disponível em: https://doi.org/10.1007/s00411-025-01117-3. DOI: https://doi.org/10.1007/s00411-025-01117-3
[25] SIEBEL, O. F. Desenvolvimento de um dosímetro in vivo a MOSFET para aplicações em radioterapia. 2013. Tese (Doutorado em Engenharia Elétrica) – Universidade Federal de Santa Catarina, Florianópolis, 2013. Disponível em: https://repositorio.ufsc.br/handle/123456789/122778. Acesso em: 10 ago. 2025.
[26] SCHWANK, J. R. et al. Radiation effects in MOS oxides. IEEE Transactions on Nuclear Science, v. 55, n. 4, p. 1833-1853, 2008. Disponível em: https://doi.org/10.1109/TNS.2008.2001040. DOI: https://doi.org/10.1109/TNS.2008.2001040
[27] INTERNATIONAL ATOMIC ENERGY AGENCY. IAEA Health Report No. 8: development of procedure for in vivo dosimetry in radiotherapy. Vienna: IAEA, 2013.
[28] BEKMEZCI, Mustafa et al. Determining Validity, Reliability, and Sample Size in Qualitative Research. PaperASIA, v. 41, n. 4b, p. 287-300, 2025. DOI: https://doi.org/10.59953/paperasia.v41i4b.545
[29] ANDREO, P. et al. Influence of energy and angular spread on stopping-power ratios for electron beams. Physics in Medicine & Biology, v. 34, n. 6, p. 751-768, 1989. DOI: https://doi.org/10.1088/0031-9155/34/6/010
[30] ICRU - INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS. Determination of absorbed dose in a patient irradiated by beams of X or gamma rays in radiotherapy procedures. Washington: ICRU, 1976.
[31] ANDREO, P. et al. Absorbed dose determination in external beam radiotherapy: an international Code of Practice for dosimetry based on standards of absorbed dose to water. Vienna: International Atomic Energy Agency, 2000. (IAEA Technical Report Series, n. 398).
Descargas
Publicado
Número
Sección
Licencia
Derechos de autor 2026 Luiz Flavio Kalil Telles, L. M. Maria, Divanízia N. Souza, Luiz Antonio Pereira dos Santos, Clayton Augusto Benevides

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/






















