Development and calibration of a portable detection device for in vivo measurement of high-energy photon emitters incorporated by humans
DOI:
https://doi.org/10.15392/bjrs.v6i2A.438Palabras clave:
Internal monitoring, Internal dosimetry, BioassayResumen
This work presents the evaluation of the applicability and sensitivity of a portable detection device specially designed for in vivo measurement of high-energy photon emitters in the human body. The calibration was performed at the In-Vivo Monitoring Laboratory of the IRD. The equipment consists of a lead-collimated NaI (Tl) 3”x3” scintillation detector assembled on a tripod. The detector and its compact associated electronics are connected via USB cable to a portable PC. Spectrum acquisition and analysis is controlled by specific commercially available software. The calibration was performed using a standard liquid source of 152Eu contained in 3 L polyethylene bottles. The evaluation of the system is based on the estimation of the minimum committed effective doses associated to the minimum detectable activities, calculated using current biokinetic and dosimetric models available in the literature. The dose detection limits for selected radionuclides of interest in an emergency scenario have shown to be far below 1 mSv allowing the system to be useful in accident situations.
Descargas
Referencias
IAEA – International Atomic Energy Agency. Communication dated 7 December 2016 received from the Permanent Mission of the Republic of Korea concerning a Joint Statement on Supporting Nuclear and Radiological Terrorism Preparedness and Response Capabilities. Information Circular - INFCIRC/904. IAEA, 2016.
BARNETT, D., J. et al. Understanding Radiologic and Nuclear Terrorism as Public Health Threats: Preparedness and Response Perspectives. The Journal of Nuclear Medicine, v. 47, 2006.
EMAER. Doctrine of the Preparation and Employment of the FAB in Transmission Missions in Chemical, Biological, Radiological and Nuclear Defense (CBRND). DCA 1-6 - Nº 43/3SC2, EMAER, 2014.
GALEEV, Roman et al. Suitability of Portable Radionuclide Identifiers for Emergency Incorporation Monitoring. Radiation Protection Dosimetry, v. 173, p. 145-150, 2017.
Avaliable at: <http://www.nucleide.org/Laraweb>. Last Accessed: 2 May 2017.
DANTAS, B. M. et al. A Mobile Bioassay Laboratory for the Assessment of Internal Doses Based on Vivo and in Vitro Measurements. Health Physics Society, v. 99, p. 449-452, 2010.
IAEA - International Atomic Energy Agency. Methods for Assessing Occupational Radiation Doses due to Intakes of Radionuclides. Safety Reports Series Nº 37, IAEA, 2004.
BERTELLI, L., Melo, D. R.; Lipsztein, J., Cruz-Suarez, R. AIDE – Internal Dosimetry Software. Radiation Protection Dosimetry 130 (3), p. 358-367, 2008.
Descargas
Publicado
Número
Sección
Categorías
Licencia
Derechos de autor 2021 Brazilian Journal of Radiation Sciences (BJRS)

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/