Estudo comparativo de descritor de dose em exames pediátricos de tomografia computadorizada
DOI:
https://doi.org/10.15392/bjrs.v3i1A.126Palavras-chave:
Computer Tomography, Pediatric, DoseResumo
Computed tomography is considered a high radiation dose modality, and therefore establishment of diagnostic reference levels is highly recommended. These levels are expected not to be exceeded for standard procedures, when good practice is applied. Most CT scanners display a dose index, CTDIvol. For pediatric studies, this dose index is measured using a standard phantom and an ionization chamber, and does not represent patient dose, but a reference measurement. The objective of this study was to investigate the CTDIvol dose descriptor in head CT scans of a sample of pediatric patients, comparing them with the DRL presented in the literature. Data of head CT without contrast of 40 pediatric patients were retrospectively collected. The acquisition parameters of each examination were extracted from DICOM header and analyzed to assess the protocols typically used by technicians. The mean values of CTDIvol of each group were compared with the DRL values from literature. The measurement of accuracy indicated a difference of 11,6% with the CTDIvol registered by the scan, which can be explained by six different protocols used by technicians for the same exam. The variation is specially critic for the youngers than 1 year. Some children were submitted to a protocol with 50% higher dose than others. This group has 4% higher mean CTDIvol than DRL in literature, while other groups have lower values. The results show the role of medical physicist, optimizing clinical protocols to guarantee the maximum image quality with minimum dose.
Downloads
Referências
AAPM – American Association of Physicists in Medicine. The Measurement, Reporting, and Management of Radiation Dose in CT. AAPM Report 60, 2008.
Alamo-Maestre, et al, CT radiation dose in children: a survey to establish age-based di-agnostic reference levels in Switzerland. European Society of Radiology, v. 18, p. 1980 – 1986 (2008).
Aurich, N.K, Níveis de Referência Diagnóstica de Tomografia Computadorizada em Pacientes Pediátricos. Porto Alegre (2012).
BfS, Referenzwerte für diagnostische und interventionelle Röntgenuntersuchungen. Bundesamt für Strahlenschutz. (2010). Disponível em: http://www.bfs.de/de/ion/medizin/referenzwerte02.pdf. Último acesso em 24 de Março de 2014.
Dalmazo, J. et al, Otimização da Dose em Exames de Rotina em Tomografia Computa-dorizada: Estudo de Viabilidade em um Hospital Universitário. São Paulo (2010).
Dunn, et al, Doses from Computed Tomography (CT) Examinations in the UK - 2003 Review. Health Protection Agency - NRPB (2005).
Galasnki, et al, Paediatric CT Exposure Practice in the Federal Republic of Germany. mhh - Medizinhische Hochschule Hannover (2005). Disponível em: http://www.mhhannover.de/fileadmin/kliniken/diagnostische_radiologie/download/Report_German_Paed-CT-Survey_2005_06.pdf. Último acesso em 20 de Março de 2014.
Image Gently, Disponível em: http://www.imagegently.org/ Último acesso em 20 de Março de 2014.
Image Wisely, The CTDI Paradigm: A Practical Explanation for Medical Physicists. Disponível em: http://www.imagewisely.org/Imaging-Modalities/Computed-Tomography/Medical-Physicists/Articles/The-CTDI-Paradigm. Último acesso em: 04 de Ju-lho de 2014.
Kikuti, C.F, et al, Estimativa da Dose em Exames de Tomografia de Abdome com Base nos Valores de DLP. São Paulo (2013).
National Council on Radiation Protection and Measurements. Radiation Protection In Pe-diatric Radiology. Report No. 68. Bethesda, MD: NCRP (1978).
Pina, D.R, et al, Controle de Qualidade e Dosimetria em Equipamentos de Tomografia Computadorizada. São Paulo (2009).
Siemens. Somaton Emotion 6/16-slice configuration Application Guide (2007).
Strauss, K, "Child-size” the radiation delivered to pediatric patients, disponível em http://www.imagegently.org/WhatcanIdoasa/Physicist.aspx#2037486-ct. Último acesso em 20 de Março de 2014.
V. TSAPAKI, et al, Dose Reduction in CT while Maintaining Diagnostic Confidence: Diagnostic Reference Levels at Routine Head, Chest, and Abdominal CT—IAEA-coordinated Research Project. Radiology, 240(3), 828-834, (2006).
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2015 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/