Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
DOI:
https://doi.org/10.15392/bjrs.v6i3.528Palavras-chave:
wounds contaminated, incorporation of radionuclides, performance of detectors, emergency radiologicalResumo
In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological performance of the equipment, the experimental set up and the scenario of the occurrence of the accident. The methodology to evaluate the performance of the detectors use the comparison of the attenuation coefficient value of each radionuclide obtained by the attenuation curve of tissue-equivalent material to the theoretical value established by NIST in each experimental set up. The good performance was defined when the difference between the experimental and theoretical value is close to zero. The experimental set ups were chosen according to the types of possible measurements performed in the various scenarios of the radiological accident. The detectors used were Personal Radiation Dosimeter, IdentiFINDER2, Cadmium Telluride and Hyper Pure Germanium. The results for 241Am showed better performance with HPGe and IdentiFINDER2 shielded. For the 60Co the best performance occurred with the shielded and collimated IdentiFINDER2. For the 137Cs, the HPGe detector presented the best performance.
Downloads
Referências
NCRP – National Council on Radiation Protection and Measurements. Development of a Bio-kinetic Model for Radionuclide-Contaminated Wounds and Procedures for their Assessment, Dosimetry and Treatment. NCRP Report 156, Bethesda: NCRP, 2006.
FALK, R. B.; DAUGHERTY, N. M.; ALDRICH, J. M.; FURMAN, F. J.; HILMAS, D. E. Ap-plication of Multi-Compartment Wound Models to Plutonium-Contaminated Wounds Incurred by Former Workers at Rocky Flats. Health Phys, v. 91(2), p. 128-143, 2006.
LOPES, A. G.; TAUHATA, L.; BERTELLI, L., Protocolo para trato de pessoas que sofre-ram ferimentos com material radioativo em acidentes radiológicos e nucleares. Tese de disser-tação de Mestrado. Rio de Janeiro: IRD, 2015.
ICRU – International Commission on Radiation Units and Measurements. Tissue substitutes in radiation dosimetry and measurements. ICRU Report 44, Bethesda: ICRU, 1989.
LNHB – Laboratorie National Henri Becquerel. Recommended data. Available at: <http://www.nucleide.org/DDEP_WG/DDEPdata.htm>. Last accessed: 15 December. 2015.
NIST – National Institute of Stardards and Technology. X-Ray Mass Attenuation Coefficients.
Available at: <http://physics.nist.gov/PhysRefData/XrayMassCoef/tab4.html>. Last accessed: 15 December. 2015.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/