Evaluation of a plane-parallel ionization chamber for low-energy radiotherapy beams
DOI:
https://doi.org/10.15392/bjrs.v3i1A.62Resumo
A plane-parallel ionization chamber, with a sensitive volume of 6.3 cm3, developed at the Calibration Laboratory of IPEN (LCI), was utilized to verify the possibility of its application in low-energy X-ray beam qualities for radiotherapy (T-qualities). This homemade ion chamber was manufactured using polymethyl methacrylate (PMMA) coated with graphite, and co-axial cables. In order to evaluate the performance of this ionization chamber, some characterization tests were performed: short- and medium-term stability, leakage current, saturation, ion collection efficiency, polarity effect and linearity of response. The maximum value obtained in the short-term stability test was 0.2%, in accordance with the limit value of 0.3% provided by the IEC 60731 standard. The saturation curve was obtained varying the applied voltage from -400 V to +400 V, in steps of 50 V, using the charge collecting time of 20 s. From the saturation curve two other characteristics were analyzed: the polarity effect and the ion collection efficiency, with results within the international recommendations. The leakage current of the ionization chamber was measured in time intervals of 20 minutes, before and after its irradiations, and all the results obtained were in agreement with the IEC 60731 standard. The linearity of response was verified utilizing the T-50(b) radiation quality, and the ionization chamber was exposed to different air kerma rates. The response of the ionization chamber presented a linear behavior. Therefore, all results were considered satisfactory, within international recommendations, indicating that this homemade ionization chamber presents potential routine use in dosimetry of low-energy radiotherapy beams.
Downloads
Referências
HORTON, J. L. Handbook of radiation therapy physics, Englewood Cliffs, N. J: Prentice-Hall, 1987.
MA, C.M.; COFFEY, C. W.; DEWERD, L. A.; LIU, C.; NATH, R.; SELTZER, S. M.; SEUNTJENS, J. P. AAPM protocol for 40–300 kV X-ray beam dosimetry in radiotherapy and radiobiology. Med Phys, v. 28(6), p. 868–892, 2001.
MALINVERNI, G.; STASI, M.; BAIOTTO, B.; GIORDANA, C.; SCIELZO, G.; GABRIELE, P. Clinical application and dosimetric calibration procedure of the superficial and orthovoltage therapy unit Therapax DXT300. Tumori, v. 88(4), p. 331–337, 2002.
DOBELBOWER, R. R.; MITSUYUKI, A. Intraoperative Radiation Therapy, Boca Raton, FL: CRC Press, 1989.
KRAUS-TIEFENBACHER, U.; SCHEDA, A.; STEIL, V.; HERMANN, B.; KEHRER, T.; BAUER, L.; MELCHERT, F.; WENZ, F. Intraoperative radiotherapy (IORT) for breast cancer using the Intrabeam system. Tumori, v. 91(4), p. 339– 345, 2005.
WENZ, F.; BLANK, E.; WELZEL, G.; HOFMANN, F.; ASTOR, D. ; NEUMAIER, C.; HERSKIND, C.; GERHARDT, A.; SUETTERLIN, M.; KRAUS-TIEFENBACHER, U. In-traoperative radiotherapy during breast-conserving surgery using a miniature Xray generator (Intrabeam): theoretical and experimental background and clinical experience. Women’s Health, v. 8(1), p. 39–47, 2012.
LEUNG, M. K. K.; CHOW, J. C. L.; CHITHRANI, B. D.; LEE, M. J. G.; OMS, B.; JAFFRAY, D. A. Irradiation of gold nanoparticles by X-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production Med Phys, v. 38(2), p. 624–631, 2011.
MA, C.-M. X-ray therapy equipment, low and medium energy, in Encyclopedia of Medical Devices and Instrumentation, 2nd ed. New Jersey: John Wiley & Sons, p. 580–590, 2006.
KHAN, F. M. The Physics of Radiation Therapy. 1st ed. Baltimore: Willians & Wilkins, 1984.
PODGORSAK, E. B. Radiation Oncology Physics: A Handbook for Teachers and Stu-dents. Vienna: International Atomic Energy Agency, 2005.
PERINI, A.P.; NEVES, L.P.; VIVOLO, V.; XAVIER, M.; KHOURY, H.J. ; CALDAS, L.V.E. Characterization of a CT ionization chamber for radiation field mapping. Appl Radiat Isot, v. 70, p. 1300-1303, 2012.
PERINI, A.P.; NEVES, L.P.; FERNÁNDEZ-VAREA, J. M.; CASSOLA, V.; KRAMER, R.; KHOURY, H.J.; CALDAS, L.V.E. A new parallel-plate graphite ionization chamber as a 60Co gamma radiation reference instrument. Radiat Phys Chem, v. 95, pp. 106-108, 2014.
BIPM - Bureau International des Poides at Mesures.
Measuring conditions used for the calibration of ionization chambers at the BIPM. BIPM Rapport BIPM-04/17, Sèvres: BIPM, 2004.
IEC - International Electrotechnical Commission. Medical electrical equipment - Dosime-ters with ionization chamber as used in radiotherapy. IEC Standard 60731, Genève: IEC, 2011.
IAEA - International Atomic Energy Agency. Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water. IAEA TRS 398, Vienna: IAEA, 2001.
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2015 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/