Dose distribution assessment (comparison) in the target volume treated with VMAT given by the planning system and evaluated by TL dosimeters
DOI:
https://doi.org/10.15392/bjrs.v3i1.106Resumo
Volumetric-modulated arc therapy (VMAT) is a relatively new therapy technique in which treatment is delivered using a cone beam that rotates around the patient. The radiation is delivered in a continuous gantry rotation while the cone beam is modulated by the intertwining of dynamic multileaf collimators (MLCs). Studies of VMAT plans have shown reduction in the treatment delivery time and monitor units (MU) comparable to IMRT plans improving major comfort to the patient and reducing uncertainties associated with patient movement during treatment. The treatment using VMAT minimizes the biological effects of radiation to critical structures near to the target volumes and produces excellent dose distributions. The dosimetry of ionizing radiation is essential for the radiological protection programs for quality assurance and licensing of equipment. For radiation oncology a quality assurance program is essentially to maintain the quality of patient care. As the VMAT is a new technique of radiation therapy it is important to optimize quality assurance mechanisms to ensure that tests are performed in order to preserve the patient and the equipment. This paper aims to determinate the dose distribution in the target volume (tumor to be treated) and the scattered dose distribution in the risk organs for VMAT technique comparing data given by the planning system and thermoluminescent (TL) response.
Downloads
Referências
HALL, E.J. Radiobiology for the radiologist. Lippincott, 1988.
MUNDT, A.J. Intensity Modulated Radiation Therapy – A clinical perspective. BC Decker Inc., 2005.
BORTFELD, T. Image-Guided IMRT. Springer-Verlag, 2006.
OTTO, K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med. Phys. v. 35, n. 1, p. 310–317, 2008.
VERBAKEL, W.F.; CUIJPERS, J.P.; HOFFMANS, D. Volumetric intensity- modulated arc therapy vs conventional IMRT head-and-neck cancer: A comparative planning and dosimetric study. Int. J. Radiat. Oncol. Biol. Phys. v. 74, n. 1, p. 252–259, 2008.
SHAFFER, R.; NICHOL, A.M.; VOLLANS, E. A comparison of volumetric modulated arc therapy for conventional intensity-modulated radiotherapy for frontal and temporal high-grade gliomas. Int. J. Radiat. Oncol. Biol. Phys. v. 76, n. 4, p. 1177–1184, 2009.
NGUYEN, K.; CUMMINGS, D.; LANZA, V.C.; MORRIS, K.; WANG, C.; SUTTON, J.; GARCIA, J. A dosimetric comparative study: Volumetric modulated arc therapy vs intensity-modulated radiation therapy in the treatment of nasal cavity carcinomas. Medical Dosimetry, v. 38, n. 3, p. 225-232, 2013.
ICRU - International Commission on Radiation Units and Measurements. Determina-tion of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures. Report 24, Maryland, 1976.
AAPM - American Association of Physicists in Medicine. A protocol for the determina-tion of absorbed dose from high-energy photon and electron beams (TG-21). Medical Physics, v. 10, n. 6, p. 741-771, 1983.
HANCOCK, S.S. End-to-End Radiosurgery tests with Lucy® Phantom. Radiation Therapy Department, Southeast Missouri, Hospital Missouri, 2008.
PALTA, J.R; LIU, C.; LI, J.G. Quality Assurance of Intensity-Modulated Radiation Therapy. Int. J. Radiat. Oncol. Biol. Phys. v. 71, p. 108-112, 2008.
Downloads
Publicado
Edição
Seção
Licença
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/