EVALUATION OF THE DOSE DUE TO THE POSITION OF THE PROTECTION BLOCKS USED TO PROTECT THE EYES.
DOI:
https://doi.org/10.15392/bjrs.v2i1.11Palavras-chave:
Dosimetry, Radiotherapy, Protection blocksResumo
Several techniques have been proposed to perform the radiation treatment of medulloblastoma. However, each method presents limitations, and problems have occurred during irradiation due to the application of non-coplanar fields, such as the joint protection of fields and nearby organs that may be affected during irradiation. Among these organs is the eye, located 9 mm from the cribriform plate. With the improper positioning of the protection blocks, an underdosage in the cribriform plate could bring about a relapse of the tumor due to the migration of tumor cells, whereas an overdosage in the eye may well cause opacities of the crystalline lens or a total loss of vision. This study aims to evaluate the dose levels in four techniques of radiotherapy planning according to the positioning of the protection blocks and the collimator angle. In the first two treatments, the prescribed dose was 1.5 Gy/day, using a lead block with collimator angles of 11.3° and 348.7°. In the final two treatments, the prescribed dose was of 1.8 Gy/day, using the cerrobend block with a single field set-up and collimator angles of 9° and 351°. An ALDERSON-RANDOM anthropomorphic phantom and thermoluminescent dosimeters were used to implement these measures during treatment. Dose levels applied to the eyes were as follows: in the first two treatments, 27% of the prescribed dose; in the third treatment, 41% of the prescribed dose; and in the fourth treatment, 55% of the prescribed dose. In the first two treatments the dose are still within acceptable limits to prevent future sequel. In the cribriform plate, the doses were much higher: in the first treatment, doses were on average 128.4% of the prescribed dose; in the second and third treatments, doses reached 121.7%; and in the fourth treatment, doses reached 108.7%. These values show that the lead blocks protected better than did the cerrobend blocks, and that the collimator angles of 9° and 351° reduced the dose levels in the cribriform plate; however, these remained above the original prescribed dose.
Downloads
Referências
- Cochran D. M.; Yock T. I.; Adams J. A. and Tarbell N. J. Radiation dose to the lens during craniospinal irradiation—an improvement in proton radiotherapy technique. Int. J. Radiation Oncology Biol. Phys., vol. 70, no. 5, pp. 1336–1342, 2008.
- Geber T.; Gunnarsson M.; Mattsson S., Eye lens dosimetry for interventional procedures e Relation between the absorbed dose to the lens and dose at measurement positions Radiation Measurements 46pp. 1248-1251,2011.
- Indra J. das, Kase K. R.; Fitzgerald T. J. and Ligon D. A. Study of dose perturbation parameters for eye shielding in megavoltage photon beam therapy. In. J. Rndiation Oncology Biol. Phys., Vol. 19, pp. 461-467, 1990.
- Kron T.; Hamilton C.; Roff M. AND Denhaam J. Dosimetric intercomparison for two Australian clinical trials using an anthropomorphic phantom. Int. J. Radiat. Oncol. Biol. Phys. Vol.52, n°2, pp. 566-579, 2002.
- Oiveira F. L.; Lima F. F. e Viela Ê. C.. Avaliação da dose em radioterapia crânio-espinhal para meduloblastoma . Dissertação de mestrado; 2008.
-Pawlicki T.; Luxton G.; LE Q.-T.; Findley D. and MA C.-M. Lens dose in mlc-based IMRT treatments of the hear and neck. Int. J. Radiat. Oncol. Biol. Phys. Vol. 59, n° 1, pp. 293-299, 2004.
- Rene N. J.; Brodeur M.; Parker W.; Roberge D.; Freeman C. A comparison of optic nerve dosimetry in craniospinal radiotherapy planned and treated with conventional and intensity modulated techniques. Radiotherapy and Oncology, vol.97, pp. 387–389, 2010
- Weiss E.; Krebeck M.; k¨ohler B.; Pradier O. and Hess C. F. Does the standardized helmet technique lead to adequate coverage of the cribriform plate? An analysis of current practice with respect to the icru 50 report. Int. J. Radiation Oncology Biol. Phys., vol. 49, no. 5, pp. 1475–1480, 2001.
- Woo S .Y.; Donaldson S. S.; Heck R.J.; Nielson K.L. and Shostak C. Minimizing and measuring lens dose when giving cranial irradiation. Radiotherapy and Oncology. Vol. 16, pp. 183-188, 1989.
Downloads
Publicado
Edição
Seção
Licença
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/