Image quality evaluation of a small animal PET scanner
DOI:
https://doi.org/10.15392/bjrs.v8i1.1155Palavras-chave:
Small Animal PET Scanner, Image Quality, NEMA NU 4-2008Resumo
Performance testing of small animal PET scanners is very important to ensure the high performance required for this particular type of PET scanner. In this sense, National Electrical Manufactures Association (NEMA) published its NU 4/2008 standards, a consistent and standardized methodology for measuring scanner performance parameters for small animal PET imaging. Imaging capabilities of the scanner LabPET SOLO 4 were tested during two years according NEMA NU 4/2008 methodology. Results indicates that the equipment, despite a decade of use, presents performance appropriated and similar to performance of equipments reported in Literature.
Downloads
Referências
YAO R.; LECOMTE R.; CRAWFORD E. Small-Animal PET: What is it, and why do we need it? Journal of Nuclear Medicine Technology. 2011. v.40 nº3, p.157-165.
MANNHEIM JG et al., Reproducibility and comparability of preclinical PET imaging data: A multi-center small animal PET study Journal of Nuclear Medicine. Published on March 8, 2019 as doi:10.2967/jnumed.118.221994.
BAO et al., Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards. Journal of Nuclear Medicine. 2009. 50:401-408.
NEMA - National Electrical Manufacturers Association. Performance Measurements of SmallAnimal Positron Emission Tomographs. Rosslyn VA; 2008 Standards Publication NU 4-2008.
NEMA - National Electrical Manufacturers Association. Performance Measurements of Positron Emission Tomographs (PETS). Rosslyn VA; Standards Publication NU 2-1994.
NEMA - National Electrical Manufacturers Association. Performance Measurements of Positron Emission Tomographs (PETS). Rosslyn VA; Standards Publication NU 2-2001.
NEMA - National Electrical Manufacturers Association. Performance Measurements of Positron Emission Tomographs (PETS). Rosslyn VA; Standards Publication NU 2-2007.
NEMA - National Electrical Manufacturers Association. Performance Measurements of Positron Emission Tomographs (PETS). Rosslyn VA; Standards Publication NU 2-2018.
GE Healthcare Technologies. Triumph Service Guide Technical Publication. Revision Draft 6, Copyright. Available at: <http://www.gehealthcare.com>. 2011.
TRETRAULT M. A., et al. System architecture of the LabPET small animal PET scanner. IEEE Transactions on Nuclear Science, 2008. v.55, p. 2546-2550.
FONTAINE R., et al. The hardware and signal processing architecture of LabPETTM, a small animal APD-based digital PET scanner. IEEE Transactions on Nuclear Science, February 2009. v. 56, p. 3-9.
Gamma Medica-Ideas, User Manual: Positron Emission Tomography (PET) Scanner Software - Manual for Acquisition and Processing of PET Images from the LABPET System. Software version: LABPET 1.12.0, (2010).
BELCARI, N. et al. NEMA NU-4 Performance Evaluation of the IRIS PET/CT Preclincial Scanner. IEEE Transactions on Nuclear Science, 2017. v.1, n.4, p. 301-309.
PMOD Tecnologies LCC, PMOD v.3.7. User Manual, (2015).
PRASAD, R., RATIB, O., ZAID, H., NEMA NU-04-based performance characteristics of the LabPET-8TM small animal PET scanner, Phys Med Biol. 2011, 56(20):6649-6664.
GOERTZEN et al. NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems. 2012, JNM, v. 56, p. 1300-1309.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2020 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/