Image quality in chest tomography employing three different equipment technologies
DOI:
https://doi.org/10.15392/bjrs.v9i3.1680Palavras-chave:
Computed tomography, chest, diagnostic imaging, image qualityResumo
Computed tomography represents the largest portion of the population´s exposure to ionizing radiation related to medical imaging. This article aims to assess the quality of the images through the analysis of radiologists in routine chest protocols, performed at one hospital and two diagnostic imaging clinics, and employing three equipment with different technologies. A total of 1,088 criteria were analyzed with the three imaging techniques, and the average percentage of the observed structures were 95, 99 and 99% for each service. There was an excellent correlation between observers and even an absolute agreement in some cases for the most modern technologies. The three studied devices provided acceptable dose values and images with a quality close to 100%, reducing the exposure and improving the radiological protection of patients.
Downloads
Referências
PINA, et al. Criação de um indicador eletrônico para acompanhamento de dose no setor de Tomografia Computadorizada. Brazilian Journal of Radiation Sciences. Braz. J. Rad. Sci. 2020. 08-03 (2020) 01-14.
AIEA. TSA -3 Protección radiológica en lãs Exposiciones Médicas RLA 9057 / RLA 9067. Programa Regional Del OIEA para América Latina, 2007- 2013.
KUBO, T. et al. Standard-dose vs. low-dose CT protocols in the evaluation of localized lung lesions: Capability for lesion characterization—iLEAD study. European Journal of Radiology Open. [2016 a] 67–73. Disponível em: https://www.ejropen.com/article/S2352-0477(16)30007-7/pdf. Acesso: mar. 2019.
KUBO, T. et al. Low dose chest CT protocol [50 mAs] as a routine protocol for comprehensive assessment of intrathoracic abnormality. European Journal of Radiology Open Volume 3 [2016 b] 86–94. Disponível em: https://www.ejropen.com/action/showPdf?pii=S2352-0477%2816%2930009-0. Acesso: abr. 2019.
SOUZA, G. S.; FRONER, A.P.P.; SILVA, A.M.M.; Doses em tomografia computadorizada de crânio: impacto do uso do controle automático de exposição. Revista Brasileira de Física Médica. 2017; 11[2]:21-24
ZAMPIERI, J.F.; PACINI, G.S.; ZANON M.; et al. Calcificações torácicas na ressonância magnética: correlação com a tomografia computadorizada. J Bras Pneumol.;45[4]: 2019e20180168.
ICRU - International Commission on Radiation Units and Measurements. Radiation Dose and Image-Quality Assessment in Computed Tomography, ICRU Report 87, Journal of the ICRU, v. 12, No 1, 2012. Report. 87. Disponível em: https://icru.org/content/reports/radiation-dosimetry-and-image-quality-assessment-in-computed-tomography-icru-87. Acesso: mar.2019.
SOUZA, G.S.; FRONER, A.P.P.; SILVA, A.M.M.; Levantamento de Doses em Tomografia Computadorizada em Protocolos de Crânio e Tórax. Revista Brasileira de Física Médica. 2016;10[3]:34-38.
TORRES, P.P.T.S.; RABAHI, M.F.; MOREIRA, M.A.C.; et al. Avaliação tomográfica das doenças fúngicas no tórax: abordagem por padrões e sinais. Radiol Bras. 2018 Set/Out;51[5]:313–320. Disponível em: http://dx.doi.org/10.1590/0100-3984.2017.0223. Aces-so: mai 2020.
NOSCHANG, J.; GUIMARÃES, M.D.; TEIXEIRA D.F.D.; et al. Novas técnicas no diag-nóstico por imagem do tromboembolismo pulmonar. Radiol Bras. 2018 Mai/Jun;51[3]:178–186.
SODICKSON, A.; et al. Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risk from CT of Adults. Radiology. Boston. Volume 251: Number 1—April 2009. Disponível em: https://pubs.rsna.org/doi/pdf/10.1148/radiol.2511081296. Acesso: jan. 2019.
AAPM - American Association of Physicists in Medicine. The Measurement, Reporting, and Management of Radiation Dose in CT. College Park, MD. 2008. [AAPM Report. 96]. Disponível em: https://www.aapm.org/pubs/reports/RPT_96.pdf. Acesso: mar 2019.
DORNELES, C.M.; PACINI, G.S.; ZANON, M.; et al. Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases. J Pediatr [Rio J]. 2020; 96:92-9.
EUR - European Guidelines on Quality Criteria for Computed Tomography, Luxembourg. European Commissions’ Radiation Protection & the Office for Official Publications of the European Commission. 2004.
MINITAB. Suporte ao MINITAB 17. Disponível em: https://support.minitab.com/pt-br/minitab/19/. Acesso em: 01 jun. 2017.
MÓRAN, L.M.; RODRIGUEZ, R.; CALZADO, A. et al. Image quality and dose evaluation in spiral chest CT examinations of patients with lung carcinoma. The British Journal of Radiology, 77, 839–846 2004.
SOUZA, G.S.; LANFREDI, M.P.; SILVA, A.M.M.; Parâmetros de aquisição em tomografia computadorizada para pacientes pediátricos: uma revisão bibliográfica. Revista Brasileira de Física Médica. 2018;12[3]:30-34.
ALMEIDA, R.F.; et al. Padrões de tomografia computadorizada de alta resolução na doença pulmonar intersticial [DPI]: prevalência e prognóstico. J Bras Pneumol. 2020; 46 [5]: e20190153. Disponível em: htto:// dx.doi.org/10.36416/1806-3756/e20190153. Acesso em: 20 jun. 2020
BRITO, M.C.B.; OTA M.K.; LEITÃO FILHO, F.S.S.; et al. Concordância entre radiologistas na quantificação de bronquiectasias pela tomografia computadorizada de alta resolução. Radiol Bras. 2017 Jan/Fev;50[1]:26–31.
ANTUNES, V.B.; MEIRELLES, G.S.P.; JASINOWODOLINSKI, D.; et al. Concordância entre observadores no diagnóstico das doenças pulmonares intersticiais por imagens de TCAR. J Bras Pneumol. 2010;36[1]:29-36.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/