Development of radiopaque FFF filaments for bone and teeth representation in 3D printed radiological objects
DOI:
https://doi.org/10.15392/bjrs.v10i1.1739Palavras-chave:
3D printing, Fused Filament Fabrication, Radiology, PhantomResumo
The use of 3D printing technologies is growing widely, including the possibility of design phantoms for imaging and dosimetry. For that, high attenuation tissues such as cortical bone, dentin and enamel need to be mimicked to accurately produce 3D printed phantoms, especially for Fused Filament Fabrication (FFF) printing technology. A Radiopaque FFF filament commercially available had been hard to be found; and this study aims to report, step-by-step, the development of a radiopaque FFF filament. A combination of radiopaque substances (Barium Sulfate - BaSO4 and Calcium Carbonate - CaCO3) was selected using the National Institute of Standards and Technology (NIST) XCOM tool theoretical data and added as filler in an Acrylonitrile Butadiene Styrene (ABS) matrix. The filament was homogenized and gone under first characterizations by analyzing its density, Scanning Electron Microscopy (SEM), Computed Tomography (CT) and micro-CT (µCT) scans. Three filaments were produced with different Hounsfield Units (HU) equivalences: XCT-A (1607HU), XCT-B (1965HU) and XCT-C (2624HU) with respective densities of 1.166(6) g/cm³, 1.211(2) g/cm³ and 1.271(3) g/cm³. With these values, high attenuation tissues, such as bones, dentine and enamel, can now be mimicked with FFF 3D printing technology, at a low cost of production.
Downloads
Referências
Mankovich NJ, Lambert T, Zrimec T, Hiller JB. Anatomic vascular phantom for the verification of MRA and XRA visualization and fusion. Med Imaging 1995 Physiol Funct from Multidimens Images 1995;2433:73. https://doi.org/10.1117/12.209724.
Alssabbagh et al. Evaluation of nine 3D printing materials as tissue equivalent materials in terms of mass attenuation coefficient and mass density. Int J Adv Appl Sci 2017;4:168–73. https://doi.org/10.21833/ijaas.2017.09.024.
Gear JI, Cummings C, Craig AJ, Divoli A, Long CDC, Tapner M, et al. Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT. EJNMMI Phys 2016;3:17. https://doi.org/10.1186/s40658-016-0151-6.
Niebuhr NI, Johnen W, Güldaglar T, Runz A, Echner G, Mann P, et al. Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy. Med Phys 2016;43:908–16. https://doi.org/10.1118/1.4939874.
Ivanov D, Bliznakova K, Buliev I, Popov P, Mettivier G, Russo P, et al. Suitability of low density materials for 3D printing of physical breast phantoms. Phys Med Biol 2018;63:175020. https://doi.org/10.1088/1361-6560/aad315.
Sculpteo. The state of 3D printing. Ed 2018 2018:1–30. https://info.sculpteo.com/the-state-of-3d-printing-2018.
Tappa K, Jammalamadaka U. Novel Biomaterials Used in Medical 3D Printing Techniques. J Funct Biomater 2018;9:17. https://doi.org/10.3390/jfb9010017.
Kiarashi N, Ravin CE, Nolte AC, Sturgeon GM, Segars WP, Nolte LW, et al. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data; Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data. Med Phys 2015;42:4116. https://doi.org/10.1118/1.4919771.
Shen S, Cromeens B, Han Y, Dong E, Liu W, Xu R, et al. Freeform fabrication of tissue-simulating phantoms by combining three-dimensional printing and casting. Des Qual Biomed Technol IX 2016;9700:970009. https://doi.org/10.1117/12.2212305.
Beckmann, J. and Popovic, K., 2020. Assessment of the attenuation of metal-infused filaments for 3D printing a gamma camera calibration phantom. Medical Engineering & Physics, 80, pp.60-64.
Tino, R., Yeo, A., Brandt, M., Leary, M. and Kron, T., 2021. The interlace deposition method of bone equivalent material extrusion 3D printing for imaging in radiotherapy. Materials & Design, 199, p.109439.
Ceh J, Youd T, Mastrovich Z, Peterson C, Khan S, Sasser TA, et al. Bismuth infusion of ABS enables additive manufacturing of complex radiological phantoms and shielding equipment. Sensors (Switzerland) 2017;17:1–11. https://doi.org/10.3390/s17030459.
Tino R, Yeo A, Brandt M, Leary M, Kron T. The interlace deposition method of bone equivalent material extrusion 3D printing for imaging in radiotherapy. Mater Des 2021;199:109439. https://doi.org/10.1016/j.matdes.2020.109439.
Alssabbagh M, Tajuddin AA, Abdulmanap M, Zainon R. Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality. Radiat Phys Chem 2017;135:106–12. https://doi.org/10.1016/j.radphyschem.2017.02.009.
Dancewicz OL, Sylvander SR, Markwell TS, Crowe SB, Trapp JV. Radiological properties of 3D printed materials in kilovoltage and megavoltage photon beams. Phys Medica 2017;38:111–8. https://doi.org/10.1016/J.EJMP.2017.05.051.
Shin J, Sandhu RS, Shih G. Imaging Properties of 3D Printed Materials: Multi-Energy CT of Filament Polymers. J Digit Imaging 2017;30:572–5. https://doi.org/10.1007/s10278-017-9954-9.
Savi M, Andrade MAB, Potiens MPA. Commercial filament testing for use in 3D printed phantoms. Radiat Phys Chem 2020:108906. https://doi.org/10.1016/J.RADPHYSCHEM.2020.108906.
Resnik R., Kircos LT, Misch C. Diagnostic Imaging and Techniques In: Contemporary Implant Dentistry. 3rd ed. St. Louis: Mosby Elsevier; n.d.
Sahai S, Kaveriappa S, Arora H, BharatAggarwal2. 3-D imaging in post-traumatic malformation and eruptive disturbance in permanent incisors : a case report 2011;22:473–7. https://doi.org/10.1111/j.1600-9657.2011.01038.x.
Sakuma A, Saitoh H, Makino Y, Inokuchi G, Hayakawa M, Yajima D, et al. Three-dimensional visualization of composite fillings for dental identification using CT images. Dentomaxillofacial Radiol 2012;41:515–9. https://doi.org/10.1259/dmfr/13441277.
Borges MS, Mucha JN. Bone density assessment for mini-implants position. Dental Press J Orthod 2010;15:58–60.
Hazelaar C, van Eijnatten M, Dahele M, Wolff J, Forouzanfar T, Slotman B, et al. Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes. Med Phys 2018;45:92–100. https://doi.org/10.1002/mp.12644.
Li Y, Li Z, Ammanuel S, Gillan D, Shah V. Efficacy of using a 3D printed lumbosacral spine phantom in improving trainee proficiency and confidence in CT-guided spine procedures. 3D Print Med 2018;4. https://doi.org/10.1186/s41205-018-0031-x.
Alhosseini Hamedani B, Melvin A, Vaheesan K, Gadani S, Pereira K, Hall AF, et al. Three-dimensional printing CT-derived objects with controllable radiopacity 2018;19:317–28. https://doi.org/10.1002/acm2.12278.
Price G, Biglin ER, Collins S, Aitkinhead A, Subiel A, Chadwick AL, et al. An open source heterogeneous 3D printed mouse phantom utilising a novel bone representative thermoplastic. Phys Med Biol 2020;65. https://doi.org/10.1088/1361-6560/ab8078.
Styrolution I. Technical datasheet: Terluran GP-35 2016;49:49–51. https://www.ineos-styrolution.com/INTERSHOP/web/WFS/Styrolution-Portal-Site/en_US/-/USD/ViewPDF-Print.pdf?SKU=300600120829&RenderPageType=ProductDetail (accessed February 1, 2020).
Threepopnatkul, P., W. Teppinta, and N. Sombatsompop. "Effect of co-monomer ratio in ABS and wood content on processing and properties in wood/ABS composites." Fibers and Polymers 12.8 (2011): 1007-1013.
Berger, M.J., Hubbell, J.H., Seltzer, S.M., Chang, J., Coursey, J.S., Sukumar, R., Zucker, D.S., and Olsen K. XCOM: Photon Cross Section Database (version 1.5) 2010.
Physikalisch-Technische Bundesanstalt. Radiation qualities used for studies in radiation protection 2015.
White DR, Booz J, Griffith R V., Spokas JJ, Wilson IJ. Report 44. J Int Comm Radiat Units Meas 1989;os23:NP-NP. https://doi.org/10.1093/jicru/os23.1.report44.
Kim S, Chen J, Cheng T, Gindulyte A, He J, He S, et al. PubChem 2019 update: Improved access to chemical data. Nucleic Acids Res 2019;47:D1102–9. https://doi.org/10.1093/nar/gky1033.
Valor A, Reguera E, Sa´nchez-Sinencio F. Synthesis and X-ray diffraction study of calcium salts of some carboxylic acids. Powder Diffr 2002;17:13–8. https://doi.org/10.1154/1.1414011.
CRC Handbook of Chemistry and Physics, 93rd Edition Haynes, William M., ed., CRC Press, 2012, 2664 pp., hard cover | Sigma-Aldrich n.d. https://www.sigmaaldrich.com/catalog/product/aldrich/z763241?lang=pt®ion=BR&gclid=CjwKCAjw6fCCBhBNEiwAem5SO5jtdxFiiAOq_SflL5A8IMn7PVViGOYjGNesjtsaj9NJ0K28M8jSbxoCDQYQAvD_BwE (accessed March 25, 2021).
ICRP. ICRP 110: Annexes A-D. Ann ICRP 2009;39:47–70. https://doi.org/10.1016/j.icrp.2009.07.005.
Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Second Edition | (2009) | Hsieh | Publications | Spie n.d. https://spie.org/Publications/Book/2049426?SSO=1 (accessed March 25, 2021).
Todd DB. Improving incorporation of fillers in plastics. A special report. Adv Polym Technol 2000;19:54–64. https://doi.org/10.1002/(SICI)1098-2329(20000117)19:1<54::AID-ADV6>3.0.CO;2-#.
Xu XG, Eckerman KF, editors. Handbook of anatomical models for radiation dosimetry. 1st ed. CRC Press; 2010.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2022 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/