Uncertainty evaluation in activity measurements with HPGe using two relative methods
DOI:
https://doi.org/10.15392/2319-0612.2022.2070Palavras-chave:
uncertainty, gamma emitters, germanium detectors, radionuclide metrologyResumo
Radionuclide metrology laboratories aim to provide radioactive standards for detector calibrations in nuclear safety areas with low uncertainties. Such standards are applied in nuclear industries, according to the requirements of monitoring programmes. The standard radionuclides of 133Ba, 152Eu and 166mHo are suitable to the determination of efficiency curves in HPGe detectors due to their multi-gamma emissions, which are intense and well separate in the spectrum. With efficiency curves it is possible to do the measurements without needing to use standards. In this work was made a verifying of the uncertainties obtained for the two relative methods: comparative (sample-standard) and efficiency curve. The total uncertainties obtained by sample-standard method varied from 0.4 to 1.2 % (k=1). The results using efficiency curve method are between 0.9 to 2.2 % (k=1).
Downloads
Referências
RAJPUT, M.U., AHMAD, M., AHMAD, W., Characteristic absolute efficiency response curves of a high purity germanium detector in the energy range 50-1500 keV., J. Radioanal. Nucl. Chem. v.251 (3), p.457, 2002 .
MOREL, J. X and Gamma Spectrometry, LMRI/CEA/87/188, CEN- Saclay (in French), 1987 .
FROSIO, T., MENAA, N., DUCHEMIN, C., RIGGAZ, N., THEIS, C. A New Gamma Spectroscopy Methodology Based On Probabilistic Uncertainty Estimation and Conservative Approach Appl. Radiat. Isot. V. 155 (108929) , p. 1-18, 2020 .
LEPY, M.C., PEARCE, A., SIMA, O. Uncertainties in Gamma-ray Spectrometry, Metrologia v. 52, p. 3, 2015 .
KAMINSKI, S., JACOBI, A., WILHELM, CHR. Uncertainty of Gamma-ray Spectrometry Measurement of Environmental Samples due to Uncertainties in Matrix Composition, Density and Sample Geometry . Appl. Radiat. Isot. V. 94, p. 306-313 , 2014 .
BE, M.M., CHISTE, V., DULIEU,C., BROWNE,E., CHECHEV,V., KUZMENKO,N., HELMER,R., NICHOLS, A., SCHONFELD, E., DERSCH, R. Table of Radionuclides, Sèvres, BIPM-5, 2010 .
BERNARDES, E.M.O., DELGADO, J.U., TAUHATA, L., SILVA, C.J., IWAHARA, A., POLEDNA, R., PASCHOA, A.S. 166mHo: a multi- standard for the calibration of Ge spectrometers, Appl.Radiat. Isot. v. 56 , p. 157, 2002 .
DELGADO, J.U., MOREL, J., ETCHEVERRY, M., Measurements of photon emission probabilities from the decay of 226Ra and daughters , Appl. Radiat. Isot., v. 56, p. 137, 2002 .
PIBIDA, L., HSIEH, E., FUENTES-FIGUEROA, A., HAMMOND, M.M., KARAM,L. Software studies for germanium detectors data analysis, Appl. Radiat. Isot . v. 64 (10-11) , p. 1313, 2006 .
SILVA, M.A.L., ALMEIDA, M.C.M., DELGADO, J.U. Half-life of radionuclides determined by reference source method J. Radioanal .Nucl. Chem. v. 264 (3), p. 571, 2005 .
VIDMAR ,T., KORUN, M. Calibration of L-S curves for coincidence summing corrections in gamma ray spectrometry Nucl. Instrum. Methods in Phys .Res . Section A, v. 556 (2), p. 543, 2006 .
CALIN, M. R. , CALIN, M. A. , DONE, L. , DRUKER, A. E. , CALIN, A.C. Assessment of calibration parameters for gamma-ray spectrometry systems J. Radioanal . Nucl. Chem. v. 288, p. 547, 2011 .
KOSKINAS, M. F., MOREIRA, D. S. , YAMAZAKI, I. M., TOLEDO, F. , BRANCACCIO, F. , DIAS, M. S. Primary Standardization of 57Co Appl. Radiat . Isot,.v. 68 (7-8) , p. 1344, 2010 .
LU, X and WANG, G. Absolute radioactivity measurement of 60Co , 137Cs and 166mHo by 4πβ-γ anti-coincidence method Appl. Radiat. Isot. V. 58, p. 365, 2003 .
DIAS, M. S. , TAKEDA, M. N. , KOSKINAS, M. F. Application of Monte Carlo simulation to the prediction of extrapolation curves in the coincidence technique Appl. Radiat. Isot. V. 64 , p. 1191, 2006 .
YAMADA, T. , NAKAMURA, Y. , KAWADA, Y. , SATO, Y. , HINO, Y. Standardization of 152Eu and 154Eu by 4πβ-γ coincidence method and 4π (β + γ) integral counting Appl. Radiat. Isto, v. 64, p. 1220, 2006 .
IWAHARA, A. , SILVA, M. A. L. , CARVALHO FILHO, A. E. , BERNARDES, E. M. O. , DELGADO, J. U. Determination of disintegration rates and γ-ray emission probabilities of 65Zn and 241Am , Appl. Radiat . Isot . v. 63, p. 107, 2005 .
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2022 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/