Effectiveness of polymeric gloves in radioprotection against contamination in nuclear medicine
DOI:
https://doi.org/10.15392/2319-0612.2023.2187Palavras-chave:
permeation, radioactive contamination, radiological protectionResumo
When handling unsealed radioactive sources, radiological protection attention must be taken to avoid unnecessary exposure and radioactive contaminations, and an important and necessary practice to prevent such contaminations is the use of gloves when handling these sources. The present work aimed to determine the effectiveness of contamination protection provided by different types of disposable polymeric gloves used in Nuclear Medicine Service in Clinic Hospital of Porto Alegre, testing the main radiopharmaceuticals used at this site: [99mTc]sodium pertechnetate, [18F]FDG and [131I]sodium iodide. The analysis was performed using the wipe test inside gloves intentionally contaminated on the outside with these radiopharmaceuticals. The radiation detector used to measure the contamination was a NaI(Tl) scintillator well-type counter. The results indicate that three types of gloves analyzed protect the user from [99mTc]sodium pertechnetate and [18F]FDG contamination, for permanence times with the glove after contamination for up to 15 min (interval tested). For [131I]sodium iodide, gloves are completely effective in protection as long as they are used for a time interval after contamination of the external surface of up to: Latex – 5 min; Vinyl – 5 min; Nitrile – 10 min. Among them, the nitrile glove are the most effective, since contamination was not observed on the inner face for times equal to or less than 10 min; and, for an interval of 15 min, the percentage of permeation obtained was lower than the other two types: 3.3 times lower than vinyl glove permeation and 1.3 times lower of the latex glove permeation. It was also possible to estimate the skin dose rate due to contamination caused by iodine permeation for each glove case and time tested.
Downloads
Referências
HARRIS, S. J.; GILMORE, A. Penetration of protective gloves as a route of intake for tritiated water and 125I-labelled sodium iodide solution. Physics in Medicine and Biology, 1980.
RIDONE, S. et al. Permeability of gloves used in nuclear medicine departments to [99mTc]-pertechnetate and [18F]-fluorodeoxyglucose: Radiation protection considerations. Physica Medica, 2013.
CNEN. Diretrizes Básicas de Proteção Radiológica. Comissao Nacional de Energia Nuclear, v. 05, n. 27, p. 1–24, 2014.
CNEN. Serviços de Radioproteção. Comissão Nacional de Energia Nuclear, v. 18, p. 1–17, 2018.
CNEN. REQUISITOS DE SEGURANÇA E PROTEÇÃO RADIOLÓGICA PARA SERVIÇOS DE MEDICINA NUCLEAR. Rio de Janeiro: CNEN NN 3.05, 2013.
CRISTINI, D.; SOUZA, B. DE; VICENTE, R. Wipe Sampling - Review of the Literature. 2011 International Nuclear Atlantic Conference, p. 24–28, 2011.
CAPINTEC, INC. CAPTUS 3000 THYROID UPTAKE SYSTEM OWNER’S MANUAL. , 2014.
SANTOS, L. R. et al. Evaluation of the minimum detectable activity of whole-body and thyroid counters of the in vivo monitoring laboratory of IPEN/CNEN-SP. Scientia Plena, v. 8, n. num. 11, 2012.
HWANG, H. et al. Estimating MDA for low-level radioactivity in a radiobioassay laboratory. Available at: <https://inis.iaea.org/collection/NCLCollectionStore/_Public/25/009/25009442.pdf>, last acessed: 05 nov. 2022.
WB MANN, C. et al. Report No. 058 – A Handbook of Radioactivity Measurements Procedures, 2nd ed. [s.l: s.n.]. Available at: https://ncrponline.org/shop/reports/report-no-058-a-handbook-of-radioactivity-measurements-procedures-2nd-ed-1985/, last acessed: 05 nov. 2022.
IPEN. Ficha de Informações de Segurança de Produtos Químicos -FISPQ IOD-IPEN-131, 2015. Available at https://www.ipen.br/portal_por/conteudo/centro_de_radiofarmacia/bulas/fispq_IOD-IPEN-131.pdf, last acessed: 06 mar. 2023.
IPEN. BULA IOD-IPEN-131, 2015. Available at https://intranet.ipen.br/portal_por/conteudo/geral/BULA%20IOD-IPEN-131%20Profissional%20da%20saude.pdf, last acessed: 06 mar. 2023.
DELACROIX, D. et al. Radionuclide and radiation protection data handbook 2nd edition (2002). Radiation Protection Dosimetry, v. 98, n. 1, p. 9–18, 2002.
BAILEY, D. L. et al. Nuclear Medicine Physics. A Handbook for Teachers and Students. Medical Physics, 2014.
KU, H. H. Notes on the use of propagation of error formulas. Journal of Research of the National Bureau of Standards, Section C: Engineering and Instrumentation, v. 70C, n. 4, p. 263, out. 1966.
Junior, P.F., Silveira F. L. On type A and type B uncertainties and its propagation without derivatives: a contribution to incorporate contemporary metrology to Physics’ laboratories in higher education. Revista Brasileira de Ensino de Física, 2011. Available at https://lume.ufrgs.br/handle/10183/98918?locale-attribute=pt_BR, last acessed: 06 mar. 2023.
C.B. Ashmore, J.R. Gwyther and H.E. Sims. Some Effects of pH on iodine volatility in containment. Canadian Nuclear Society, 1994. Avalilable in https://inis.iaea.org/collection/NCLCollectionStore/_Public/29/030/29030429.pdf, last acessed: 06 mar. 2023.
IPEN. INSTITUTO DE PESQUISAS ENERGÉTICAS E NUCLEARES Autarquia associada. Available at: <https://www.ipen.br/portal_por/portal/interna.php?secao_id=39&campo=16391>. Last acessed: 05 nov. 2022.
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2023 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/