Um design de colimador para uso em detectors de HPGe em feixes de nêutrons

Autores

  • Carlos Gabriel Santos da Silva Instituto de Pesquisas Energéticas e Nucleares, IPEN/CNEN, Av. Prof. Lineu Prestes, 2242 – Cidade Universitária – CEP 05508-000 São Paulo – SP – Brazil
  • F. A. Genezini Instituto de Pesquisas Energéticas e Nucleares, IPEN/CNEN, Av. Prof. Lineu Prestes, 2242 – Cidade Universitária – CEP 05508-000 São Paulo – SP – Brazil
  • A. P. S. Souza Idaho National Laboratory, INL, 1955 N. Fremont Ave. Idaho Falls, ID 83415, United States of America
  • I.S. Ribeiro Jr. Instituto de Pesquisas Energéticas e Nucleares, IPEN/CNEN, Av. Prof. Lineu Prestes, 2242 – Cidade Universitária – CEP 05508-000 São Paulo – SP – Brazil

DOI:

https://doi.org/10.15392/2319-0612.2024.2750

Palavras-chave:

Monte Carlo, PGAA, Design de colimadores, Blindagem gama

Resumo

O uso de detectores em feixes de nêutrons, particularmente em instalações de Análise por Ativação com Nêutrons e Gamagrafia Prompt (PGNAA), é essencial para uma análise elementar precisa. No entanto, a operação desses detectores em campos de radiação de alta dose apresenta desafios significativos, principalmente devido às altas taxas de radiação de fundo. Neste estudo, três projetos distintos de colimadores foram avaliados por meio de simulações Monte Carlo, utilizando o espectro gama de um reator de fissão como fonte de radiação. O colimador com melhor desempenho demonstrou otimizar a performance dos detectores HPGe, aumentando a precisão da detecção elementar sob condições de alta radiação de fundo.

Downloads

Os dados de download ainda não estão disponíveis.

Referências

[1] E. Babcock, N. Szekely. et al. Using neutron methods SANS and PGAA to study evolution of structure and composition of alkali-doped polybenzimidazole membranes. Journal of Membrane Science, v. 577, p.12-19, 2019.

[2] T. Belgya, Prompt Gamma Activation Analysis at the Budapest Research Reactor, Physics Procedia, v. 31, p. 99-109, 2012.

[3] Belgya, T., Kis, Z., Szentmiklósi, L. et al. A new PGAI-NT setup at the NIPS facility of the Budapest Research Reactor. Journal of Radioanalytical and Nuclear Chemistry, v.278, p. 713-718, 2008.

[4] Cristache, C., Gméling, K., Culicov, O. et al. An ENAA and PGAA comparative study of anoxic Black Sea sediments. Journal of Radioanalytical and Nuclear Chemistry, v. 279, p. 7-12, 2009.

[5] Masayuki Igashira, Hideo Kitazawa, Nobuhiro Yamamuro. A heavy shield for the gamma-ray detector used in fast neutron experiments. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v. 245, n. 2-3, p. 432-437, 1986.

[6] A. Jalil, A. Chetaine, H. Amsil, K. Embarch, A. Benchrif, K. Laraki, H. Marah. Determining PGAA collimator plug design using Monte Carlo simulation. Nuclear Engineering and Technology, v. 53, n. 3, p. 942-948, 2021.

[7] E.J. Kluge, C. Stieghorst, F.E. Wagner, R. Gebhard, Zs. Révay, J. Jolie. Archaeometry at the PGAA facility of MLZ – Prompt gamma-ray neutron activation analysis and neutron tomography. Journal of Archaeological Science: Reports, v. 20, p. 303-306, 2018.

[8] Litaize, O., Serot, O. & Berge, L. Fission modelling with FIFRELIN. The European Physical Journal A, v. 51, n. 12, p. 177 – 191, 2015.

[9] Werner, Christopher John and Armstrong, Jerawan Chudoung and Brown, Forrest Brooks and Bull, et al. MCNP User's Manual Code Version 6.2, Technical Report LA-CP-13-00634, Los Alamos National Laboratory. Los Alamos, NM, USA, 2016.

[10] Roos, M., Atomenergi, A. B., Kristinas, D. SOURCES OF GAMMA RADIATION IN A REACTOR CORE. Journal of Nuclear Energy. Part B. Reactor Technology, v.1, n. 2, p. 98 -104, 1959.

[11] Schoueri, R.M., Domienikan, C., de Toledo, F., Andrade, M.L., Pereira, M.A.S., Pugliesi, R. The new facility for neutron tomography of ipen-cnen/sp and its potential to investigate hydrogenous substances. Applied Radiation and Isotopes,v. 84, p. 22–26. doi:10.1016/j.apradiso.2013.10.019.

[12] Szentmiklósi, L., Kasztovszky, Z., Belgya, T., Révay, Z., Kis, Z., Maróti, B., Gméling, K., Szilágyi. fifteen years of success: user access programs at the budapest prompt-gamma activation analysis laboratory. Journal of Radioanalytical and Nuclear Chemistry, v.309, p. 71-77, 2016.

Downloads

Publicado

07-07-2025

Como Citar

Um design de colimador para uso em detectors de HPGe em feixes de nêutrons. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 12, n. 4B (Suppl.), p. e2750, 2025. DOI: 10.15392/2319-0612.2024.2750. Disponível em: https://bjrs.org.br/revista/index.php/REVISTA/article/view/2750. Acesso em: 17 jul. 2025.