Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF
DOI:
https://doi.org/10.15392/bjrs.v7i2A.582Palavras-chave:
U3Si2, XRF, WDXRF.Resumo
The determination of silicon (Si), total uranium (U) and impurities in uranium-silicide (U3Si2) samples by wavelength dispersion X-ray fluorescence technique (WDXRF) has been already validated and is currently implemented at IPEN’s X-Ray Fluorescence Laboratory (IPEN-CNEN/SP) in São Paulo, Brazil. Sample preparation requires the use of approximately 3 g of H3BO3 as sample holder and 1.8 g of U3Si2. However, because boron is a neutron absorber, this procedure precludes U3Si2 sample’s recovery, which, in time, considering routinely analysis, may account for significant unusable uranium waste. An estimated average of 15 samples per month is expected to be analyzed by WDXRF, resulting in approx. 320 g of U3Si2 that wouldn’t return to the nuclear fuel cycle. This not only impacts in production losses, but generates another problem: radioactive waste management. The purpose of this paper is to present the mathematical models that may be applied for the correction of systematic errors when H3BO3 sample holder is substituted by cellulose-acetate {[C6H7O2(OH)3-m(OOCCH3)m], m = 0~3}, thus enabling U3Si2 sample’s recovery. The results demonstrate that the adopted mathematical model is statistically satisfactory, allowing the optimization of the procedure.U3Si2, XRF, WDXRF.Downloads
Referências
M. A. SCAPIN, V. L. R. SALVADOR, M. E. B. COTRIM, M. A. F. PIRES. Uncertainty measurement evaluation of WDXRF and EDXRF techniques for the Si and Utotal determination in U3Si2 nuclear fuel. J Radioanal Nucl Chem, DOI: 10.1007/s10967-010-0897-6, 2011.
M. A. SCAPIN, M. B. E. COTRIM, C. P. SILVA, M. A. F. PIRES, Application of multivari-ate calibration for simultaneous determination of major and minor constituents in U3Si2 by WDXRF technique. J. Radioanal. Nucl. Chem., DOI 10.1007/s10967-014-3332-6, 2014.
WEST, M.; ELLIS, A. T.; . POTTS, P. J.; STRELI. C.; VANHOOF, C.; WOBRAUSCHEK, P. 2015 Atomic Spectrometry Update – a review of advances in X-ray fluorescence spectrometry and their applications. J. Anal. At. Spectrom, DOI 10.1039/C5JA90033F, 2015.
IPEN - Instituto de Pesquisas Energéticas e Nucleares. CCN se adequa para atender demanda do RMB. São Paulo, Brasil, 2015. Available at: <https://www.ipen.br/portal_por/portal/interna.php?secao_id=38&campo=1977>. (2015). Last ac-cessed: 17 Nov. 2017.
M. A. SCAPIN, M. B. E. COTRIM, C. P. SILVA, M. A. F. PIRES, Application of multivari-ate calibration for simultaneous determination of major and minor constituents in U3Si2 by WDXRF technique. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, 2013, Recife, Annals… Available at: <http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/46/021/46021415.pdf>. Last ac-cessed: 17 Nov. 2017.
D. W. PRESTON; E. R. DIETZ, The art of experimental physics, Nova York: John Wiley & Sons, 1991.
RIGAKU CORPORATION. Rigaku multi-element simultaneous X-ray fluorescence spec-trometer Simultix 14. Instruction Manual, Tokyo, Japan, 1999.
INMETRO – Instituto Nacional de Metrologia, Qualidade e Tecnologia. 4. Orientação sobre validação de métodos analíticos (DOQ-CGRE-008) Review 05. (2016). Available at: <http://www.inmetro.gov.br/Sidoq/Arquivos/CGCRE/DOQ/DOQ-CGCRE-8_05.pdf > Last acces-sed: 17 Nov. 2017.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/