Avaliação da qualidade da imagem e da Dose Glandular Média em Mamografia Digital.
DOI:
https://doi.org/10.15392/bjrs.v3i1A.93Palavras-chave:
mammography, radiology, dosimetry.Resumo
The most important reference for breast cancer diagnosis is still the mammography. Mammographic technology has evolved in such a way that we have digital systems nowadays. Thus, image generation quality control must evolve as well. In this work, we have evaluated digital image quality and entrance skin dose (ESD) for different breast thicknesses simulated by PMMA plates (one, two, three and four centimeters) for different target filter combinations, suggesting a protocol optimization to the mammographic automatic system.We have used CDMAM 3.4 phantom (a contrast detail phantom) and its software in order to analyze digital images from a Siemens Mammomat Inspiration mammographic equipment. It has been used three combinations of target-filter: Molybdenum Molybdenum, Molybdenum Rhodium, Tungsten Rhodium. Different peak tensions were tested to each configuration: 24 kVp, 26 kVp, 28 kVp and 30 kVp. Altogether 52 different configurations were tested. In order to measure ESD, we used Radcal’s 10x5–6M ionization chamber.Results show that automatic configuration does not offer an optimized process. Tungsten Rhodium was the best option for all breast thicknesses, once it offered the best relation between image quality and mean glandular dose. This result differs from literature which states that the Molybdenum Molybdenum combination is the best option for thin breasts.
Downloads
Referências
ARTINIS. CDMAM Manual: Contrast-Details Phantom CDMAM 3.4. Walburg, 2010.
COATES, A.M.; DIXON, A.M.; HUCKLE, J. A comparison of image quality and radiation dose between a cellular grid and a linear grid using a mammography phantom. Radiography, v. 18, p. 250-255, 2012.
DANTAS, M. V. A. Dose Glandular e Controle de Qualidade de Imagem em Serviços de Mamografia com Sistema de Radiografia Computadorizada. 2010.Dissertação (Mestrado em Ciência e Tecnologia das Radiações, Minerais e Materiais) – Centro de Desenvolvimento da Tec-nologia Nuclear, CNEN, Belo Horizonte,2010.
EMANUALLU , S. et al. Dosimetric and image quality comparison of two digital mammog-raphy units with different target/filter combinations: Mo/Mo, Mo/Rh, W/Rh, W/Ag. Radiol Med, v 116, p.310-18, 2011.
EUREF - European Reference Organisation for Quality Assured breast Cancer Screening and Diagnosis servisse. European Guidelines for quality assurance in breast cancer screening and diagnosis. Belgium, 2006.
FLORIAN, J. F. E et al. Intra-individual comparison of Average Glandular Dose of Two Digi-tal Mammography Units using Different Anode Filter Combinations. Academic Radiology, v.16, p. 1272-1280, 2009.
INCA, Instituto Nacional do Câncer. Disponível em <http://www.inca.gov.br/estimativa/2014>. Acesso em: 27 de maio de 2014.
MARTINS, L. A.L.; BARRA, A. A.; LUCENA, C. E. M. Microcalcificações Mamárias Sus-peitas de Malignidade. Revista Brasileira de Cancerologia, v56, p. 251-258, 2010.
SANTOS, A. F. Física Médica em Mamografia, 1ª edição. Rio de Janeiro: Revinter, 2010.
TOROI, P. et al. Experimental investigation on the choice of the tungsten/rhodium an-ode/filter combination for an amoprhus selenium-based digital mammography system. Eur Radi-ol, v. 17, p. 2368-2375, 2007.
VAHEY, K. et al. A comparison between the electronic magnification (EM) and true magni-fication (TM) of breast phantom images using a CDMAM phantom. European Journal of Ra-diology, v. 81, p. 1514-1519, 2012.
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2015 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/