Interlaboratory comparison of two homemade pencil type ionization chambers
DOI:
https://doi.org/10.15392/2319-0612.2024.2329Palabras clave:
pencil type ionization chamber, radiation dosimetry, computed tomography beamsResumen
Computed tomography (CT) is a diagnostic exam responsible for the highest dose values received by the patients during the procedure. Over the years, this kind of equipment has been improved to ensure that the patients do not receive unnecessary doses. For this reason it is important to keep a quality control program for the CT equipment. To perform the dosimetry in CT beams, the instrument used is usually a pencil type ionization chamber with a sensitive volume length of 10 cm. However, this kind of detector is available with different sensitive volume lengths. The aim of this study was to compare the response of two homemade pencil type ionization chambers with sensitive volume lengths of 10 cm and 30 cm in the laboratories of Instituto de Pesquisas Energéticas e Nucleares (IPEN, Brazil) and National Physical Laboratory (NPL, UK). The characterization tests were performed, and the results obtained are within the international recommended limits. The only difference observed in the response of the two chambers in both laboratories is the fact that the ionization current obtained in all the tests at the IPEN is higher than at the NPL, because of the beam characteristics.
Descargas
Referencias
BOONE, J.M. The trouble with CTDI100. Medical Physics, v. 34, p. 1364-1371, 2007.
MCCOLLOUGH, C.H. “Computed tomography technology and dose in the 21st century”. Health Physics, v. 116, p. 157–162, 2019.
SMITH-BINDMAN, R.; WANG, Y.; CHU, P.; et al., International variation in radiation dose for computed tomography examinations: prospective cohort study. British Medical Journal, v. 364, p. 1-12, 2019.
BUSHONG, S.C. Radiologic Science for Technologists: Physics, Biology and Protection. Rio de Janeiro, Elsevier, 2010.
SUZUKI, A.; SUZUKI, M.N. Use of a pencil-shaped ionization chamber for measurement of exposure resulting from a computed tomography scan. Medical Physics. v. 5, p. 536-539, 1978.
IAEA, International Atomic Energy Agency. Calibration of Radiation Protection Monitoring Instruments. Safety Report Series IAEA SRS 16, IAEA, Vienna, 2000.
NEVES, L.P.; PERINI, A.P.; CALDAS, L.V.E. Development and characterization of a new cylindrical ionization chamber for dosimetry of 60Co beams. IEEE Transactions on Nuclear Science. v. 60, p. 712-715, 2013.
PERINI, A.P.; NEVES, L.P.; FERNÁNDEZ-VAREA, J.M.; BÜERMANN, L.; CALDAS, L.V.E. Evaluation and simulation of a new ionization chamber design for use in computed tomography beams. IEEE Transactions on Nuclear Science. v. 60, p. 768-773, 2013.
CASTRO, M.C. Development and Characterization of Special Ionization Chambers for Computed Tomography Beams. Master in Science, Instituto de Pesquisas Energéticas e Nucleares, Universidade de São Paulo (In Portuguese), 2016.
CASTRO, M.C.; SILVA, N.F.; XAVIER, M.; ANDRADE, M.E.A.; KHOURY, H.J.; CALDAS, L.V.E. Development and tests of a 30 cm pencil-type ionization chamber for dosimetry in standard and clinical CT beams. Biomedical Physics & Engineering Express, v. 3(5), p. 1-9, 2017.
IEC, International Electrotechnical Commission. Medical Diagnostic X-ray Equipment. Radiation Conditions for Use in the Determination of Characteristics. 2nd ed. IEC, Genève, (IEC 61267), 2005.
IEC, International Electrotechnical Commission. Medical Electrical Equipment-Dosimeters with Ionization Chambers and/or Semi-Conductor Detectors as used in X-Ray Diagnostic Imaging. Technical Report, IEC, Genéve, (IEC 61674), 1997.
Descargas
Publicado
Número
Sección
Licencia
Derechos de autor 2024 Brazilian Journal of Radiation Sciences (BJRS)

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/