This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power. The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool. Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building. LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool. A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case. So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case. The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration. 

ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode. KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case. Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.

Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases. The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.

 

Downloads

Download data is not yet available.

References

Abdelhady A., Radiological performance of hot water layer system in open pool

type reactor, Alexandria Engineering Journal (2013).

Scale: A Comprehensive Modeling and Simulation Suite for Nuclear Safety Analysis and De

sign, ORNL/TM-2005/39 Version 6.1, June 2011.

Abdelhady A. Dose rates from the accidental withdrawal of a fuel element from an

open pool type reactor. J Nucl Eng Radiat Sci 2018; 4:021010-1.

Thomas M. Miller, Douglas E. Peplow, GUIDE TO PERFORMING COMPUTATIONAL

ANALYSIS OF CRITICALITY ACCIDENT ALARM SYSTEMS, ORNL/TM-2013/211.

ICRU-57, “Conversion Coefficients for Use in Radiological Protection Against External Radia

tion,” International Commission on Radiation Units & Measurements, Bethesda, MD

(1998).

ICRP (International Commission on Radiation Protection) (1991), Recommendations of the In

ternational Commission on Radiation Protection, Pergamon Press, Oxford, England, ICRP

Publication 60.

Origin(Pro), Version 8.5 SR1. OriginLab Corporation, Northampton, MA, USA.

Downloads

Published

2022-02-18

How to Cite

Abdelhady, A. (2022). Deriving formula to simulate the radiological behavior during LOCA in open pool type reactor. Brazilian Journal of Radiation Sciences, 10(1). https://doi.org/10.15392/bjrs.v10i1.1723

Issue

Section

Articles