Deriving formula to simulate the radiological behavior during LOCA in open pool type reactor
DOI:
https://doi.org/10.15392/bjrs.v10i1.1723Keywords:
LOCA, Open pool reactor, KENO-VI code, ORIGEN-S code, MAVRIC code, radiation dose rate.Abstract
This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power. The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool. Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building. LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool. A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case. So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case. The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration.
ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode. KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case. Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.
Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases. The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.
- Views: 132
- PDF Downloads: 164
Downloads
References
Abdelhady A., Radiological performance of hot water layer system in open pool
type reactor, Alexandria Engineering Journal (2013).
Scale: A Comprehensive Modeling and Simulation Suite for Nuclear Safety Analysis and De
sign, ORNL/TM-2005/39 Version 6.1, June 2011.
Abdelhady A. Dose rates from the accidental withdrawal of a fuel element from an
open pool type reactor. J Nucl Eng Radiat Sci 2018; 4:021010-1.
Thomas M. Miller, Douglas E. Peplow, GUIDE TO PERFORMING COMPUTATIONAL
ANALYSIS OF CRITICALITY ACCIDENT ALARM SYSTEMS, ORNL/TM-2013/211.
ICRU-57, “Conversion Coefficients for Use in Radiological Protection Against External Radia
tion,” International Commission on Radiation Units & Measurements, Bethesda, MD
(1998).
ICRP (International Commission on Radiation Protection) (1991), Recommendations of the In
ternational Commission on Radiation Protection, Pergamon Press, Oxford, England, ICRP
Publication 60.
Origin(Pro), Version 8.5 SR1. OriginLab Corporation, Northampton, MA, USA.
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/