Quality and Quantity Assessment of Tomographic Exams That Can Be Performed on Existing Hybrid Equipment at Botucatu Medical School Nuclear Medicine Services
DOI:
https://doi.org/10.15392/bjrs.v10i2.1799Keywords:
Computed Tomography, Nuclear Medicine, Hybrid Equipment, Image Quality AssessmentAbstract
Computed Tomography (CT) has been one of the greatest innovations for medical diagnosis. Among the main features of CT is its ability to provide high-quality anatomical and functional images. Other important imaging modalities are the ones conducted in Nuclear Medicine (NM), which, with the use of radiotracers, makes it possible to obtain metabolic and molecular images in vivo. The union of NM and CT imaging modalities is possible through hybrid equipment. The purpose of this research is to evaluate the quality and quantity of tomographic exams that can be performed in hybrid equipment. To complete this research analyzes of the ability to perform CT exams in the room that holds a Single Photon Emission Computed Tomography/ Computed Tomography SPECT/CT equipment in an NM facility were carried out. The evaluation criteria were: equipment quality control, image quality assessment by a subjective method as per European Guidelines on Quality Criteria for Computed Tomography (EUR), and assessment of shielding of the room, as an indicator of how many exams can be performed. Considering the results of the barrier thickness, the Botucatu Medical School and Nuclear Medicine facility is capable of performing 100 tomography exams per week. According to information obtained in the facility, currently, approximately 20 scans are performed weekly, so there is an increased opportunity of up to 80 exams weekly. Therefore, the hybrid equipment is qualified to perform diagnostic tests with superior image quality, compared to those performed in CT equipment.
- Views: 263
- PDF Downloads: 208
- XML Downloads: 16
Downloads
References
BACH‐GANSMO, Tore et al. SPECT/CT hybrid imaging; with which CT?. Contrast media & molecular imaging, v. 5, n. 4, p. 208-212, 2010. DOI: https://doi.org/10.1002/cmmi.375
DENNIS, Jennifer L.; GEMMELL, Alastair J.; NICOL, Alice J. Optimization of the CT com-ponent of SPECT-CT and establishment of local CT diagnostic reference levels for clinical prac-tice. Nuclear medicine communications, v. 39, n. 6, p. 493-499, 2018. DOI: https://doi.org/10.1097/MNM.0000000000000831
MATTSSON, Sören; SÖDERBERG, Marcus. Radiation dose management in CT, SPECT/CT and PET/CT techniques. Radiation protection dosimetry, v. 147, n. 1-2, p. 13-21, 2011. DOI: https://doi.org/10.1093/rpd/ncr261
WANG, Yuankai; LIU, Zhuang. CT scan optimization in SPECT/CT equipment of nuclear med-icine. Zhongguo yi Liao qi xie za zhi= Chinese Journal of Medical Instrumentation, v. 37, n. 4, p. 308-310, 2013.
HCFMB, Transparência 2020 covid. Available:< https://www.hcfmb.unesp.br/transparencia-covid19/ >. Accessed: April 7, 2021.
Comissão Nacional de Energia Nuclear. Requisitos de Radioproteção e Segurança para Servi-ços de Medicina Nuclear. CNEN-NN-3.05; 2013.
MINISTÉRIO DA SAÚDE. Requisitos sanitários para a organização e funcionamento de serviços de radiologia diagnóstica ou intervencionista. Resolução RDC nº 330/2019.
International Atomic Energy Agency. Quality Assurance Programme for Computed Tomogra-phy: Diagnostic and Therapy Applications. IAEA Human Health Series No. 19, 2012.
American Association of Physicists in Medicine. Acceptance testing and quality control of pho-tostimulable storage phosphor imaging systems, AAPM Report No. 93, Report of AAPM Task Group 10, AAPM. 2006.
MINISTÉRIO DA SAÚDE. AGÊNCIA NACIONAL DE VIGILÂNCIA SANITÁRIA. ALDRED, M. A. Radiodiagnóstico Médico: Segurança e Desempenho de Equipamentos. Brasíl-ia: Ministério da Saúde, 2005. (Resolução 1016/05).
American College of Radiology. Computed Tomography Quality Control Manual, Copyright 2017.
MENZEL, H. G. European Guidelines on Quality Criteria for Computed Tomography Europe-an Guidelines on Quality Criteria. Luxemb. Eur. Comm. Off. Publ. 1, 46–60 (1999).
PELEGRINO BASTOS MAUÉS, Nadine Helena et al. Abdomen–pelvis computed tomogra-phy protocol optimization: an image quality and dose assessment. Radiation protection dosimetry, v. 184, n. 1, p. 66-72, 2019. DOI: https://doi.org/10.1093/rpd/ncy181
JURIK, A. et al. Clinical use of image quality criteria in computed tomography: a pilot study. Radiation protection dosimetry, v. 90, n. 1-2, p. 47-52, 2000. DOI: https://doi.org/10.1093/oxfordjournals.rpd.a033142
NATIONAL COMMITTEE ON RADIATION PROTECTION (US). Structural shielding design for medical x-ray imaging facilities. NCRP, 2004.
KUSANO, Maggie; CALDWELL, Curtis B. Dose equivalent rate constants and barrier trans-mission data for nuclear medicine facility dose calculations and shielding design. Health physics, v. 107, n. 1, p. 60-72, 2014. DOI: https://doi.org/10.1097/HP.0000000000000051
MINISTÉRIO DA SAÚDE. Dispõe sobre requisitos sanitários para a garantia da qualida-de e da segurança em sistemas de tomografia computadorizada médica, e dá outras providên-cias. Brasília, 27 de Maio de 2021. (Instrução normativa n°93/2021).
Comissão Nacional de Energia Nuclear. Diretrizes Básicas de Radioproteção. CNEN-NN-3.01; 2005.
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/