Design and development of an alignment test device for clinical X-ray equipment with 3D print and low-cost materials

Authors

  • Eduardo Henrique Miranda Arruda Universidade Federal de Goiás
  • Jonas Oliveira da Silva Universidade Federal de Goiás
  • Murilo Felisberto Morais de Assunção Secon Serviços de Radioproteção https://orcid.org/0000-0003-2183-8518

DOI:

https://doi.org/10.15392/bjrs.v10i2A.2024

Keywords:

Alignment Test, 3D Print, Low-cost materials, Quality Assurance, Radiology.

Abstract

In this paper is presented the design and development of a low-cost device for the Alignment Test, one of the quality tests for radiodiagnostic equipment. The device was designed with open-source software and was built with a 3D printer. Our focus was to create a model with low-cost, that can be easily produced and handled. The prototype was tested on a conventional radiodiagnostic equipment and presented satisfactory results considering the initial goals.

 

Downloads

Download data is not yet available.

References

UNSCEAR. Sources and effects of ionizing radiation: UNSCEAR 2008 report to the General Assembly with scientific annexes. New York: UNSCEAR, 2010.

Brasil. Ministério da Saúde. Instrução Normativa N° 90, de 27 de Maio de 2021. In: Diário Oficial da União. Edição : 101, Seção : 1, Página : 149. Brasília, DF: Ministério da Saúde; Agência Nacional de Vigilância Sanitária ; 2021.

Secretaria de Estado da Saúde. Resolução Normativa 002/DIVS/SES, de 18 de maio de 2015. In: Diário Oficial do Estado. DIRETRIZES BASICAS DE PROTEÇÃO RADIOLOGICA EM RADIOLOGIA DIAGNÓSTICA E INTERVENCIONISTA. Santa Catarina: Secretaria de Estado da Saúde, 2015.

Brasil. Ministério da Saúde. Instrução Normativa N° 91, de 27 de Maio de 2021. In: Diário Oficial da União. Edição : 101, Seção : 1, Página : 150. Brasília, DF: Ministério da Saúde; Agência Nacional de Vigilância Sanitária ; 2021.

SILVA, Marcos Otaviano Da; CARVALHO, Antônio Carlos Pires; AZEVEDO, Ana Cecília Pedrosa De. Levantamento das condições de funcionamento dos serviços de radiologia de hospitais públicos e universitários do Rio de Janeiro*. v. 37, n. 4, p. 271–278, 2004. DOI: https://doi.org/10.1590/S0100-39842004000400010

VENTOLA, C. L. Medical Applications for 3D Printing: Current and Projected Uses. Pharmacy and Therapeutics. v. 39, n. 10, pp 704-711, 2014.

MUNDO BIC. Caneta Esferográfica BIC Cristal Precisão, Ponta Final de 0.8 mm.

Disponível em : https://www.mundobic.com.br/prod/caneta-esferografica-bic-cristal-precisao-3-cores-ponta-fina-de-0-8mm-escrita-macia-tampa-ventilada-835240/176256.

Acesso em : 02 de março de 2022.

Brazil Document, MRA- Alinhamento Do Colimador.

Disponível em : https://document.onl/documents/mra-alinhamento-do-colimador.html.

Acesso em : 04 de março de 2022.

Protocolo Español de Control de Calidad en Radiodiagnóstico. Revisión 2011. SERAM, Sociedad Española de Radiologia Médica.

Downloads

Published

2022-07-21

How to Cite

Miranda Arruda, E. H., Oliveira da Silva, J. ., & Felisberto Morais de Assunção, M. (2022). Design and development of an alignment test device for clinical X-ray equipment with 3D print and low-cost materials . Brazilian Journal of Radiation Sciences, 10(2A (Suppl.). https://doi.org/10.15392/bjrs.v10i2A.2024