Otimização da metodologia de monitoração in vivo de 123I na tireoide em trabalhadores que atuam na produção de radiofármacos

Authors

  • Ana Letícia Almeida Dantas Instituto de Radioproteção e Dosimetria - IRD-CNEN
  • Mylena Queiroz Saraiva UFRJ
  • Eder Augusto Lucena IRD - CNEN
  • Bernardo Maranhão Dantas IRD - CNEN

DOI:

https://doi.org/10.15392/bjrs.v6i2A.521

Keywords:

internal dosimeter, in vivo monitoring, nuclear instrumentation, nuclear medicine.

Abstract

123I is a radionuclide used for diagnosis in nuclear medicine. Its production in Radiopharmacy Centers poses a risk of external and internal exposure to the workers involved in this practice. Controlling this type of exposure through individual monitoring is necessary to estimate the magnitude of occupational doses. The In Vivo Monitoring Laboratory (LABMIV-IRD) develops techniques aimed at meeting the demand for in vivo monitoring of workers. This paper describes the calibration of a HPGe detection system for monitoring 123I in thyroid geometry in occupationally exposed individuals (OEI). In order to obtain the calibration curve in Efficiency (cps/dps) vs Energy (keV), it is used a thyroid-neck phantom containing a certified activity of 166mHo homogeneously distributed. Based on the calibration curve it is calculated the specific calibration factor for the quantification of 123I in the thyroid. The sensitivity of the technique is evaluated by determining the minimum detectable activity (MDA), minimum detectable intake (MDI) and minimum detectable effective dose (MDED). It was obtained a calibration factor of (0.0079 ± 0.0001) cps/dps, a MDA of 5Bq, a MDI of 2.78x106 Bq and a MDED of 3.23x10-1 mSv. The technique is sufficiently sensitive for in vivo measurement of 123I in the thyroid and is suitable for the monitoring of workers occupationally exposed to this radionuclide in  radiopharmaceutical production plants.

Downloads

Download data is not yet available.

Author Biographies

Ana Letícia Almeida Dantas, Instituto de Radioproteção e Dosimetria - IRD-CNEN

Laboratório de Monitoração in vivo - LABMIV Divisão de Dosimetria - DIDOS Instituto de Radioproteção e Dosimetria - IRD-CNEN Tel: +55 21 21732826

Mylena Queiroz Saraiva, UFRJ

Instituto de Física - UFRJ

Eder Augusto Lucena, IRD - CNEN

Laboratório de Monitoração in vivo - LABMIV Divisão de Dosimetria - DIDOS Instituto de Radioproteção e Dosimetria - IRD-CNEN Tel: +55 21 21732826

Bernardo Maranhão Dantas, IRD - CNEN

Laboratório de Monitoração in vivo - LABMIV Divisão de Dosimetria - DIDOS Instituto de Radioproteção e Dosimetria - IRD-CNEN Tel: +55 21 21732826

References

COMISSÃO NACIONAL DE ENERGIA NUCLEAR (CNEN). Diretrizes Básicas de Proteção Radiológica. Norma CNEN-NE-3.01. Rio de Janeiro, RJ: CNEN, 2014.

INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA). Assessment of Occupational Exposure Due to Intakes of Radionuclide. Safety Guide No. RS-G-1.2, 1999.

International Commission on Radiological Protection (ICRP). ICRP Publication 68: Dose Coefficients for Intakes of Radionuclides by Workers. Annals of the ICRP Volume 24/4, 1995.

DANTAS, B.M.; DANTAS, A.L.A.; ACAR, M.E.D.; CARDOSO, J.C.S.; JULIÃO, L.M.Q.C.; LIMA, M.F.; TADDEI, M.H.T.; ARINE, D.R.; ALONSO, T.; RAMOS, M.A.P.; FAJGELJ, A. Accreditation and training on internal dosimetry in a laboratory network in Brazil: An increasing demand. Radiation Protection Dosimetry, v. 144, No. 1–4, p. 124–129, 2011.

International Atomic Energy Agency (IAEA). Methods for Assessing Occupational

Radiation Doses due to Intakes of Radionuclides. Safety Reports Series No. 37. IAEA, Vienna, 2004.

International Commission on Radiological Protection (ICRP). ICRP Publication 78:

Individual Monitoring for Internal Exposure of Workers. Annals of the ICRP Vol. 27/3-4, 1998.

ARAUJO, F.; LUCENA, E.A.; SOUSA, W.O.; DANTAS, A.L.A.; DANTAS, B.M., Evaluation of internal occupational exposure by 123I in a radiopharmaceutical production facility, Radiation Measurements v. 71, p. 300-304, 2014.

INTERNATIONAL COMMISION ON RADIOLOGICAL PROTECTION (ICRP), ICRP Publication 66. The human respiratory tract model. Annals of the ICRP Volume 23/4, 1994.

BERTELLI, L. et al. AIDE: internal dosimetry software. Radiation Protection Dosimetry, v. 130, n. 3, p. 358-367, 2008.

Downloads

Published

2018-07-19

How to Cite

Dantas, A. L. A., Saraiva, M. Q., Lucena, E. A., & Dantas, B. M. (2018). Otimização da metodologia de monitoração in vivo de 123I na tireoide em trabalhadores que atuam na produção de radiofármacos. Brazilian Journal of Radiation Sciences, 6(2A (Suppl.). https://doi.org/10.15392/bjrs.v6i2A.521

Most read articles by the same author(s)