IMAGE QUALITY ANALYSIS OF AN INDUSTRIAL INSTANT NON-SCANNING TOMOGRAPHY SYSTEM WITH DIFFERENT COLLIMATORS
DOI:
https://doi.org/10.15392/bjrs.v7i2A.561Keywords:
Collimators, Industrial Tomography, Monte Carlo SimulationAbstract
The greatest impact of the computed tomography (CT) applications currently occurs in medicine. In industry there is much interest of using CT in order to know the interior of: (i) industrial objects; (ii) machines and their means of production. The purpose of this tomography is to: (a) control the quality of the final product and (b) optimize production and analyze the quality of the means of production. An instant non-scanning tomography system is being developed at the IPEN. This tomography comprised different collimators was simulated with Monte Carlo using the MCNP4C. The image quality was evaluated with Matlab® 2013b analyzing the contrast to noise (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to identify which collimator fits better to the tomography in development. It was simulated three situations; (i) with no collimator; (ii) ø 25x 50 mm2 cylindrical collimator with a septum of ø5.0 x 50 mm2; (iii) ø25 x 50 mm2 cylindrical collimator with a slit septum of 24 x 5.0 x 50 mm3. RMSE values for no collimator presented better results. CNR showed that no collimator and slit collimator reaches the same CNR values, but no collimator decreases more than the slit collimator as the number of iteration rises. The hole collimator reaches a higher CNR value, however decreases more than the others. The spatial resolution with no collimator and slit collimator were around 31.9 mm, and for the hole collimator was around 20 mm
- Views: 129
- PDF Downloads: 130
Downloads
References
CHAOUKI, J, LARACHI, F, DUDUKOVIC, M.P. Non-Invasive Monitoring of Multiphase Flows. In: CHAOUKI, J, LARACHI, F, DUDUKOVIC, M.P Computer-assisted gamma and X-ray tomography: Application to multiphase flow In Non-Invasive Monitoring of Multiphase Flows, 1st ed.; Elsevier: Amsterdam, The Netherlands, 1997; p 47 - 97.
ISMAILA, I., GAMIOB J.C. Tomography for multi-phase flow measurement in the oil industry. Flow measurement and instrumentation. v. 16, p. 145-155, 2002.
VELO A.F, HAMADA M.M., CARVALHO D.V.S., MARTINS J.F.T, MESQUITA C.H., A portable tomography system with seventy detectors and five gamma-ray sources in fan beam geometry simulated by Monte Carlo method. Flow measurement and instrumentation. v. 53, p. 89-94, 2017.
JOHANSEN, G. A.; JACKSON, P. Radioisotope Gauges for Industrial Process Measurements. John Wiley & Sons, 2004.
MAAD, R., JOHANSEN G.A. Experimental analysis of high-speed gamma-ray tomography performance. Measurement science and Technology, v. 19, p. 1-10, 2008,
FISCHER F, HOPPE D, SCHLEICHER E, MATTAUSCH G, FLASKE H, BARTEL R AND HAMPEL U. An ultra-fast electron beam x-ray tomography scanner. Measurement science and technology, v. 19, p. 1-11, 2008.
Disponível em <https://www.inl.gov/>. Acesso em 06 jan 2018.
PELOWITZ, D.B. MCNP-X TM User’s Manual, Version 2.5.0. 2005. LA-CP-05-0369. Los Alamos National Laboratory.
SALGADO, C.M., BRANDÃO L.E.B., SCHIRRU, R., PEREIRA, C.M.N.A., CONTI C.C. Validation of a NaI(Tl) detector's model developed with MCNP-X code. Progress in Nuclear Energy, v. 59, p. 19-25, 2012.
HADIZADEH H., MOWLAVI, A.A., THOMPSON, M.N., HAKIMABAD, H. M. Proper shielding for Na(Tl) detectors in combined neutron-gamma fields using MCNP. Nuclear Instruments and Methods in Physics, v. 522, p. 447-454, 2004.
JEHOUANI, A., ICHAOUI, R., BOULKNEIR, M. Study of the NaI(Tl) efficiency by Monte-Carlo method. Applied Radiation and Isotopes, v. 53, p. 887-89, 2000.
CHRISTIANSON O., CHEN J. J.S., SAIPRASAD G., FILLIBEN J.J, Peskin A., TRIMBLE C., SEIGEL E L., SAMEI E. An improved index of image quality for task-based performance of CT iterative reconstruction across three commercial implementations. Radiology, v. 275, p. 725-734, 2015
SMITH, STEVEN W. The scientist and engineer's guide to digital signal processing. 2nd ed, San Diego, California Technical Publishing, 1999.
RICHARD S.L, HUSARIK D.B., YADAVA G., MURPHY S.N., SAMEI E. Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms. Medical Physics, v. 39, p. 4115 – 4122, 2012.
SAMEI E., FLYNN M.J., REIMANN D.A. A method for measuring the pre- sampled MTF of digital radiographic systems using an edge test device. Medical. Physics, v. 25, p. 102–113, 1998.
MAAD R., HJERTAKER B.T., JOHANSEN G.A. and OLSEN Ø. Dynamic characterization of a high speed gamma-ray tomography. Flow Measurement and Instrumentation, v. 21, p. 538-545, 2010.
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/