Verification of angular dependence in MOSFET detector
DOI:
https://doi.org/10.15392/bjrs.v7i2A.734Keywords:
MOSFET, angular dependence, reproducibility.Abstract
In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of meas-urement, as well as easy handling. Nevertheless, its true differential is to allow reading of dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in the patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Exper-imental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (±1 SD) for Cs-137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient.- Views: 147
- PDF Downloads: 67
Downloads
References
WHO – World Health Organization. World Health Organization: Who is cancer? Availa-ble at: <http://www.who.int/cancer/en/>. Last accessed: 01 Dec. 2017.
INCA – Instituto Nacional do Câncer. Instituto Nacional do Câncer: Tratamento do Câncer. Available at <http://www2.inca.gov.br/wps/wcm/connect/cancer/site/tratamento> Last ac-cessed: 01 Dec. 2017.
INCA – Instituto Nacional do Câncer. Instituto Nacional do Câncer: Radioterapia. Avai-lable at <http://www.inca.gov.br/conteudo_view.asp?ID=100> Last accessed: 01 Sept. 2017.
SCALCHI, P., FRANCESCON, P., Calibration of a MOSFET detection system for 6-MV in-vivo dosimetry. Int. J. Radiation Oncology Biol. Phys., v. 40, p. 987-993, 1998.
GOPIRAJ, A.; BILLIMAGGA, R. S.; RAMASUBRAMANIAN, V. Performance characte-ristics and commissioning of MOSFET as an in-vivo dosimeter for high energy photon external be-am radiation therapy. Reports of Practical Oncology & Radiotherapy, v. 13, p. 114-125, 2008.
BOWER, M. W. Physical anthropomorphic phantom of a one-year-old child with real-time dosimetry, Gainesville, Florida, United States of America, 1997.
RAMANI, R.; RUSSEL, S.; O’BRIEN, P. Clinical dosimetry using MOSFETs, Int. J. Ra-diation Oncology Biol. Phys., v 37, p.959-964, 1997.
RAMASESHAN, R.; KOHLI, K. S.; ZHANG, T. J.; LAM, T.; NORLINGER, B.; HAL-LIL, A.; ISLAM, M. Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy, Phys. Med. Biol., v 49, p. 4031-4048, 2004.
SHARP, R.E.; PATER, S.L. The use of pMOS dosimeters at megagray total doses, AEA Technol, RADECS, 1995.
SOUBRA, M.; CYGLER, J.; MACKAY, G. Evaluation of dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter, Med. Phys., v 21, p. 567-572, 1994.
BEST MEDICAL CANADA. Best Medical Canada: MOSFET Dosimeters. Available at: <http://www.bestmedicalcanada.com/product_dosimeters.html> Last accessed: 01 Dec. 2017.
SILVA JR, I.A. Desenvolvimento e Implementação de um Sistema Automatizado para Adequação do Processo de Calibração de Monitores de Radiação Gama, Universidade de São Paulo, São Paulo, Brazil, 2012.
KUMAR, A. S. et al. Characteristics of mobile MOSFET dosimetry system for megavoltage photon beams. J. Med Phys. v. 39, p. 142-149, 2014.
BEST MEDICAL CANADA. Operator’s manual for Mobile MOSFET System. Ottawa, Canada, 2008.
SCALCHI, P. et al. Characterization of a new MOSFET detector configuration for in vivo skin dosimetry. Medical Physics, v. 32, p. 1571-1578, 2005.
Published
How to Cite
Issue
Section
Categories
License
Copyright (c) 2021 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/