Volume-dose indexes and dose prescription descriptive review of radiosurgery planning

Authors

  • Pedro Argôlo Piedade Radioterapia São Sebastião, Dosemed Soluções and RT Medical System

DOI:

https://doi.org/10.15392/bjrs.v7i3B.889

Keywords:

index, radiosurgery, prescription.

Abstract

In Stereotactic radiosurgery (SRS), indexes are used to compare plans, comparing treatment techniques and evaluate clinical complications. However, they have some limitations and dependencies that need to be well known. Therefore, the analysis using indices is better suited for comparison of plans for the same patient (lesion). The evaluation of stereotactic plans must be undertaken with great care and criteria because there is a huge amount of information between different dose distributions of treatment plans. The objectives are to show some tools for planning analysis in SRS their limitations, some indexes descriptive review in the literature that seek to quantify the three properties mentioned and discuss the concepts involved in SRS dose prescription.

Downloads

Download data is not yet available.

Author Biography

  • Pedro Argôlo Piedade, Radioterapia São Sebastião, Dosemed Soluções and RT Medical System
    Radioterapia São Sebastião

References

SCHELL, M. C. ; BOVA, F. J. ; LARSON D. A. Stereotactic Radiosurgery Report of Task Group 42 (Report No. 54). 1995.

DEARNALEY D. P. ; KHOO V. S. ; NORMAN A. R. ; Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: A randomised trial. Lancet 1999; 353:267–272.

GIRAUD P. ; HELFRE S. ; LAVOLE A. Non-small-cell bronchial cancers: Improvement of survival probability by conformal radiotherapy. Cancer Radiother 2002;6:125s–134s.

ARMSTRONG J. ; MCGIBNEY C. The impact of three-dimensional radiation on the treatment of non-small cell lung cancer. Radiother Oncol 2000;56:157–167.

CORN B. W. ; HANKS G. E. ; SCHULTHEISS T. E. Conformal treatmentof prostate cancer with improved targeting: Superiorprostate-specific antigen response compared to standard treatment. Int J Radiat Oncol Biol Phys 1995;32:325–330.

GIRAUD P. ; JAULERRY C. ; BRUNIN F. Upper aerodigestivetract cancers: Clinical benefits of conformal radiotherapy andintensity modulation. Cancer Radiother 2002;6:37s– 48s.

HAYMAN J. A., MARTEL M. K., TEN HAKEN R. K. Dose escalationin non-small-cell lung cancer using three-dimensionalconformal radiation therapy: Update of a phase I trial. J ClinOncol 2001;19:127–136.

NAKAMURA J., VERHEY L. J., SMITH V. Dose conformity of gamma knife radiosurgery and risk factors for complications. Int J Radiat Oncol Biol Phys 2001;51:1313–1319.

SOLBERG T., BOEDEKER K. L., FOGG R. Dynamic arc radiosurgery field shaping: A comparison with static field conformal and noncoplanar circular arcs. Int J Radiat Oncol Biol Phys 2001; 49:1481–1491.

HAZARD L., WANG B., SKIDMORE T. B., CHERN S., SALTER B. J., JENSEN R. L. AND SHRIEVE D. C., Conformity of linac-based stereotactic radiosurgery using dynamic conformal arcs and micro-multileaf collimator. Int J Radiat Oncol Biol Phys 2009;73(2):562-570

VERHEY L. J., SMITH V. The physics of radiosurgery. Sem Rad Onc, 1995;5(3):175-191.

HAMILTON R. J., KUCHNIR F. T., SWEENEY P. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 1995;33(5):1221-1228.

CARDINALE R. M., BENEDICT S. H., WU Q. L. A comparison of three stereotactic radiotherapy techniques; ARCS vs. noncoplanar fixed fields vs. intensity modulation. Int J Radiat Oncol Biol Phys 1998;42(2):431-436.

WAGNER T.H., BOVA F.J., FRIEDMAN W.A. A simple and reliable índex for scoring rival stereotactic radiosurgery plans. Int J Radiat Oncol Biol Phys 2003;57(4):1141-1149

BRENNER D. J. Dose, volume, and tumor-control predictions in radiotherapy. Int J Radiat Oncol Biol Phys 1993;26:171–179.

COLOMBO F., FRANCESCON P., CORA S. Evaluation of linear accelerator radiosurgical techniques using biophysical parameters (NTCP and TCP). Int J Radiat Oncol Biol Phys 1995; 31:617– 628.

KHAN FM. Treatment Planning in Radiation Oncology. 2nd ed. Philadelphia (PA): Lippincott Williams and Wilkins; 2007. 204p.

MARKS L. B., YORKE E. D., JACKSON A. Use of normal tissue complication probability models in the clinic. Int. J. Radiation Oncology Biol. Phys., 2010;76(Suppl. 3):S10–S19.

EMAMI B., LYMAN J., BROWN A. Tolerance of normal tissueto therapeutic irradiation. Int J Radiat Oncol Biol Phys 1991;21:109–122.

FEUVRET L., NOEL G., MAZERON J. J. Conformity index: A review. Int J Radiat Oncol Biol Phys 2006;64:333–342.

SHAW E, KLINE R, GILLIN M. Radiation Therapy Oncology Group: Radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys 1993;27:1231–1239.

VAN’T RIET A., MAK A. C., MOERLAND M. A. A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate. Int J Radiat Oncol Biol Phys 1997;37:731–736

PADDICK I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. J Neurosurg2000;93:219 –222

LOMAX N. J. AND SCHEIB S. G. Quantifying the degree of conformity in radiotherapy treatment planning. Int J Radiat Oncol Biol Phys 2003;55(5):1409-1419.

JACKIE Q.R., WESSELA B.W., EINSTEIN D.B., MACIUNAS R.J., KIM E.Y. AND KINSELLA T. J. Quality of coverage: Conformity measures for stereotactic radiosurgery. J Appl Clin Med Phys 2003;4(4):374-381

F. W. J. OLVER, D. W. LOZIER, R. F. BOISVERT, AND C. W. CLARK, editors, 2010, NIST Handbook of Mathematical Functions (Cambridge University Press).

SOUHAMI L. Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: final report of RTOG protocol 90-05. Int J Radiat Oncol Biol Phys. 2000 May 1;47(2):291-8

LAWRENCE Y. R., LI X. A., EL NAQA I. Radiation dose-volume effects in the brain. Int. J. Radiation Oncology Biol. Phys., 2010;76(Suppl. 3):S20–S27.

LEVEGRÜN S., HOF H., ESSIG M. Radiation-induced changes of brain tissue after radiosurgery in patients with arteriovenous malformations: correlation with dose distribution parameters. Int J Radiat Oncol Biol Phys 2004;59(3):796-808.

BLONIGEN B. J., STEINMETZ R. D., LEVIN L. Irradiated Volume as a Predictor of Brain Radionecrosis After Linear Accelerator Stereotactic Radiosurgery. Int J Radiat Oncol Biol Phys 2010;77(4):996-1001.

BOVA F. J., MEEKS S. L., FRIEDMAN W. A. Stereotactic plan evaluation tool, the UF Index. Int J Radiat Oncol Biol Phys1999;45:188.

LEUNG L. H. T., CHUA D. T. T., WU P.M. A new tool for dose conformity evaluation of radiosurgery treatment plans. Int J Radiat Oncol Biol Phys1999;45(1):233-241.

NEDZI LA, KOOY H, ALEXANDER E, et. al. Variables associated with the development of complication from radiosurgery of intracranial tumors. Int J Radiat Oncol Biol Phys 1991;21:591-599.

LARSON D. A. ; GUTIN P. H. ; MCDERMOTT M. Multicenter trial update: Glioma, in 6th Annual Leksell Gamma Knife Society. Kyoto,Japan, 1994

HORWITZ E. M.; MITRA R. K.; UZZO R. G.; DAS I. J.; PINOVER W. H. Impact of target volume coverage with Radiation Therapy Oncology Group (RTOG) 98-05 guidelines for transrectal ultrasound guided permanent Iodine-125 prostate implants. Radiother Oncol. 2003 Feb;66(2):173-9.

FLICKINGERJC, LUNSFORD LD, LINSKEY ME, et al. Gamma knife radiosurgery for acoustic tumors: Multivariate analysis of four year results. RadiotherOnco 1993;127:91-98.

MEHTA M. P. ; MASCIOPINTO J. ; ROZENTAL J. Stereotactic radiosurgery for glioblastoma multiforme: Report of a prospective study evaluating prognostic factors and analyzing longterm survival advantage. Int J Radiat Oncol Biol Phys 1994;30:541-549.

NIEMIERKO A.; GOITEIN M. The influence of the size of the grid used for dose calculation on the accuracy os dose estimation. Med Phys 1989;16(2):239–247.

Clinical User Guide Rev. 1.0, iPlan RT Dose Ver. 4.1 (2008).

HONG L. X. ; GARG M. ; LASALA P. Experience of micromultileaf collimator linear accelerator based single fraction stereotactic radiosurgery: Tumor dose inomogeneity, conformity and dose fal off. Med Phys 2011;38(3):1230–1247.

NEDZI L. A. ; KOOY H. M. ; ALEXANDER E. D. Dynamic field shaping for stereotactic radiosurgery: A modelling study. Int JRadiat Oncol Biol Phys 1993;25:859–869.

ROOS D. E. ; BROPHY B. P. ; TAYLOR J. Lessons from a 17-year radiosurgery experience at the Royal Adelaide Hospital. Int J Radiat Oncol Biol Phys 2010;1-5.

PALTA J. R. ; MACKIE T. R. Uncertainties in External Beam Radiation Therapy, WI, Medical Physics Pub Corp.

LOMAX N. J. ; SCHEIB S. G. Quantifyng the degree of conformity in radiosurgery treatment planning. Int. J. Radiat. Oncol. Biol. Phys., Vol. 55, 2003, pp. 1409-1419

YOON M. ; PARK S.Y. ; SHIN D. A new homogeneity index based on statistical analysis of the dose-volume histogram. J Appl Clin Med Phys. 2007;8:9-17

Downloads

Published

2019-10-24

Issue

Section

Congresso Brasileiro de Metrologia das Radiações Ionizantes - CBMRI 2018

How to Cite

Volume-dose indexes and dose prescription descriptive review of radiosurgery planning. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 7, n. 3B (Suppl.), 2019. DOI: 10.15392/bjrs.v7i3B.889. Disponível em: https://bjrs.org.br/revista/index.php/REVISTA/article/view/889.. Acesso em: 22 nov. 2024.

Similar Articles

41-50 of 50

You may also start an advanced similarity search for this article.