Estimation of Typical Values (DRL) in Angioplasties Performed at a Radiology Service of a Hospital in Southern Brazil
DOI:
https://doi.org/10.15392/2319-0612.2024.2727Palabras clave:
Radiological Protection, Interventional Radiology, Diagnostic Reference Levels, Radiation ExposureResumen
Interventional radiology involves diagnostic and therapeutic interventions using X-ray-emitting equipment. Due to the high radiation doses administered to patients during these procedures, there is a significant risk of severe tissue reactions resulting from prolonged exposure. To prevent unnecessary high doses during patient exposures, the International Commission on Radiological Protection recommends the use of Diagnostic Reference Levels (DRLs) as an effective tool for optimizing procedures in diagnostic or interventional radiology services. This study aimed to estimate the DRLs (typical values) resulting from interventional radiology procedures conducted in a public hospital in southern Brazil. To achieve this, a database was developed to facilitate the collection of information regarding exposures during interventional procedures, enabling the establishment of DRLs specific to a single facility, known as typical values. Patient and procedure data were collected and tabulated by the Radiation Protection Service (SPR) of the hospital through consultation with the interventional radiology service’s logbook or, if necessary, the State Information System of Risk and Potential Benefit (SIERBP), followed by the application of exclusion criteria. After data collection, the typical doses received by adult patients undergoing these procedures were estimated through simple descriptive statistics, using the median of the data distribution and the standard deviation. The results obtained provide a better understanding of the necessary actions, whether optimization or protocol review, to ensure the radiological protection of patients. This approach has the potential to benefit not only the patients but also the entire professional team involved in the interventional radiology service.
Descargas
Referencias
[1] CANEVARO, L., Aspectos físicos e técnicos da radiologia intervencionista, Revista Brasileira de Física Médica, v. 3, n. 1, p. 101-115 (2009).
[2] MELO, F. A., A importância do uso do dosímetro nos profissionais médicos no serviço de hemodinâmica, Brazilian Journal of Radiation Sciences, v. 3, n.1 (2015). DOI: https://doi.org/10.15392/bjrs.v3i1A.58
[3] ROCHE, A., Radioprotection du patient en radiologie interventionnelle, Journal de radiologie, v. 91, n. 11, p. 1231-1235 (2010). DOI: https://doi.org/10.1016/S0221-0363(10)70179-7
[4] IAEA (INTERNATIONAL ATOMIC ENERGY AGENCY), Radiation Protection of Patients (RPOP). Radiation protection in interventional procedures. http://iaea.org/resources/rpop/health-professionals/interventional-procedures (2022).
[5] UNSCEAR (UNITED NATIONS SCIENTIFIC COMMITTEE ON THE EFFECTS OF ATOMIC RADIATION), Sources, Effects and Risks of Ionizing Radiation, United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) 2020/2021 Report, Volume I: Report to the General Assembly, with Scientific Annex A-Evaluation of Medical Exposure to Ionizing Radiation. http://unscear.org/unscear/uploads/documents/unscear-reports/UNSCEAR_2020_21_Report_Vol.I.pdf (2022).
[6] BUNDY, J. J. et al., Fluoroscopically-guided interventions with radiation doses exceeding 5000 mGy reference point air kerma: a dosimetric analysis of 89,549 interventional radiology, neurointerventional radiology, vascular surgery, and neurosurgery encounters. CVIR Endovascular (2020). DOI: https://doi.org/10.1186/s42155-020-00159-6
[7] MAZUIM, F. R. et al., Management of doses from medical exposures in interventional radiology: an integrative review, Brazilian Journal of Radiation Sciences, vol. 10, n. 3B (2022). DOI: https://doi.org/10.15392/2319-0612.2022.1858
[8] ICRP (INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION), Diagnostic Reference Levels in Medical Imaging. ICRP Publication 135. Ann. ICRP 46 (1). http://icrp.org/publication.asp?id=icrp%20publication%20135 (2017). DOI: https://doi.org/10.1177/0146645317717209
[9] SILVA, F. A. R. et al., Estudo comparativo dos níveis de referência em diagnóstico estabelecidos para as grandezas PKA e tempo de fluoroscopia em serviços de radiologia intervencionista localizados no estado de Minas Gerais, Revista Brasileira de Física Médica, v. 17, p. 688-688 (2023). DOI: https://doi.org/10.29384/rbfm.2023.v17.19849001688
Descargas
Publicado
Número
Sección
Categorías
Licencia
Derechos de autor 2025 Fernando Rockembach Mazuim, Isadora Tomanqueves Costa, Florencia Agustina Gutierrez Perez, Cristiny Tretto Lemes Pereira Dutra, Marcos Araquem Scopel, Tiago Trindade Hahn, Catia Simone Griebler Gomes, Daiane Cristini Barbosa Souza

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/