Development and application of an algorithm to estimate the effective energy of x-rays on conventional mammography
DOI:
https://doi.org/10.15392/2319-0612.2024.2233Palavras-chave:
dosimetry, mammography, radiation, patientsResumo
Mammography is a radiation medical exam, which makes detection of mammary microcalcifications possible at an early stage. The dose received by the patient’s breast is known as the average glandular dose, which is considered a quality control indicator. Estimation of this parameter implies knowing the effective energy of the x-ray beam delivered. This is the case when thermoluminescent dosimetry is the method of choice. The algorithm developed to discriminate the x-ray energy the mammography patient has been exposed to while undergoing routine procedures, applies two thermoluminescent dosimeters, one of them filtered by a 1 mm thick aluminum layer. The effective energy of the x-ray beam and the correction factor are obtained by knowing the relation between the filtered and non-filtered dosemeters readout. This algorithm was then used to estimate the average glandular dose following the IAEA TRS 457 protocol. The dose values computed were compared with the international diagnostic reference levels suggested by the technical literature.
Downloads
Referências
ATTIX, F. H. Introduction to Radiological Physics and Radiation: British Library, 1986. p. 71-72.
KHAN, F. M. Basic Physcis I. The Physics of Radiation Theraphy. Third edition 2003. p. 26-27.
NELSON, V.K.; HOLLOWAY, L.; McLEAN, I. D. The application of thermoluminescent dosimetry in X-ray energy discrimination. Australas Phys Eng Sci Med, v. 38(4), p. 543-549, 2015.
KRON, T.; DUGGAN, L.; SMITH, T. Dose response of various radiation detectors to synchrotron radiation. Phys Med Biol, v. 43(11), p. 3235-3259, 1998.
KRON, T.; SMITH, A.; HYODO, K. Synchroton radiation in the study of the variation of dose response in thermoluminescence dosimeters with radiation energy. Australa Phys Eng Sci Med, v. 19(4), p. 225-236, 1996.
THOMPSON, I. International Standar Reference Reference Radiations and Their Application to the Type Testing of Dosimetric Apparatus (Proc. IAEA Symposium on National and International Standardization of Radiation Dosimtry). Vienna: IAEA, p. 343-65, 1977.
TLD SYSTEMS & MATERIALES, Product Information, Solon Technologies Inc. Harshaw / QS Cristal and Dosimetry Products, 1977.
TRS 457. Dosimetry in Diagnostic Radiology: An International Code of Practice. IAEA. Vienna, 2007.
MATSUMOTO, M.; INOUE, S.; HONDA, I.; et al. Real-time Estimation for Mean Glandular Dose in Mammography. Radiat Med, v. 21(6), p. 280-284, 2003.
ICRP, 2017. Diagnostic reference levels in medical imaging. ICRP Publication 135. Ann. ICRP 46(1).
Downloads
Publicado
Edição
Seção
Categorias
Licença
Direitos autorais (c) 2024 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/