Re-characterization of pneumatic station position for short irradiations of IEA-R1 reactor for use in k0-method
DOI:
https://doi.org/10.15392/2319-0612.2026.2701Palabras clave:
k0-INAA, neutron activation method, neutron fluxResumen
This work presents the re-characterization of pneumatic station irradiation position of IEA-R1 reactor for use in k0-INAA method. The thermal-epithermal neutron flux ratio f and the epithermal neutron flux distribution factor α of the IPEN IEA-R1 reactor were determined at the pneumatic irradiation station. To obtain these values, the “bare triple monitor” method was used with 198Au –97Zr – 95Zr. To evaluate its reproducibility, the temporal variation of these parameters was analyzed, with validation carried out through irradiation of reference materials of geological origin G-S-N (granite) and biological INCT-MPH-2 (mix of herbs). The results obtained for f and α show that such values are reproducible and compatible with each other, according to the normal Gaussian distribution for up to 1 standard deviation of confidence. The results obtained for the elements detected in the samples agree with the recommended values, with relative errors (bias) less than 10%, except in the case of Mn in G-S-N (16.3%). These results indicate that it is possible to routinely use this method for LAN-IPEN researchers to analyze geological and biological samples.
Descargas
Referencias
SIMONITS, A.; DE CORTE, F.; HOSTE, J.; Single-Comparator methods in reactor neutron activation analysis. Journal of Radioanalytical and Nuclear Chemistry, v. 24, p. 31-46, 1975. DOI: https://doi.org/10.1007/BF02514380
LANGE, C. N.; CAMARGO, I. M. C.; FIGUEIREDO, A. M. G. M.; CASTRO, L.; VASCONCELLOS, M. B. A.; TICIANELLI, R. B. A Brazilian coal fly ash as a potential source of rare earth elements. Journal of Radioanalytical and Nuclear Chemistry, v. 311, p. 1235-1241, 2017. DOI: https://doi.org/10.1007/s10967-016-5026-8
DE CORTE, F. The k0-Standardization Method: A move to the optimisation of neutron activation analysis, Rijksuniversiteit Gent, Faculteit Van de Wetenschappen, Gent, Belgium, 1986.
DE CORTE, F.; MOENS, L.; SIMONITS, A.; DE WISPERLAERE, A.; HOSTE, J. Instantaneous
FLORES, J. P. O.; SILVA, P. S. C.; DIAS, M. S.; KOSKINAS, M. F.; MOREIRA, D. S.; YAMAZAKI, I. M. Calibration of the short irradiation facility for k0 - NAA implementation at the IEA-R1 reactor. Brazilian Journal of Radiation Sciences, 9(1A), São Paulo, 2021. DOI: https://doi.org/10.15392/bjrs.v9i1A.1570
DE CORTE, F.; SIMONITS, A. Recommended nuclear data for use in the k0 standardization of neutron activation analysis. At. Data Nucl. Data Tables, v. 85, p. 47-67, 2003. DOI: https://doi.org/10.1016/S0092-640X(03)00036-6
PUERTA, C. D. Aplicação do método k0-INAA no laboratório de análise por ativação com nêutrons do Ipen utilizando o programa k0-IAEA. Análise de amostras biológicas. 2013. 202 f. Dissertação (Mestrado em Tecnologia Nuclear), Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN, São Paulo. Disponível em: ‹http://repositorio.ipen.br/› (data de consulta no formato: 16/02/2024).
Jaćimović R, k0 Database, available in: https://www.kayzero.com/k0naa/k0naaorg/Nuclear_Data_SC/Entries/2020/8/24_Update_of_k0-database_I-128.html. Accessed: 05 May 2022.
IAEA – International Atomic Energy Agency. Proficiency Testing by Interlaboratory Comparison: Analytical Laboratories in Nuclear Institutions. IAEA-TECDOC-1210, Vienna, 2001.
BLAND, J.; ALTMAN M. D. G. Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet, v. 327, n. 8476, p. 307–310, 1986. DOI: https://doi.org/10.1016/S0140-6736(86)90837-8
Descargas
Publicado
Número
Sección
Categorías
Licencia
Derechos de autor 2026 João Pedro Oliveira Flores, Renato Semmler, Marina F. Koskinas, Denise Simões Moreira, Ione Makiko Yamazaki, Paulo Sérgio Cardoso da Silva, Vera Akiko Maihara

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Licencia: los artículos de BJRS tienen una licencia internacional Creative Commons Attribution 4.0, que permite el uso, el intercambio, la adaptación, la distribución y la reproducción en cualquier medio o formato, siempre que se otorgue el crédito correspondiente al autor o autores originales y a la fuente, proporcione un enlace a la licencia Creative Commons e indique si se realizaron cambios. Las imágenes u otros materiales de terceros en el artículo están incluidos en la licencia Creative Commons del artículo, a menos que se indique lo contrario en una línea de crédito al material. Si el material no está incluido en la licencia Creative Commons del artículo y su uso previsto no está permitido por la regulación legal o excede el uso permitido, el autor deberá obtener el permiso directamente del titular de los derechos de autor. Para ver una copia de esta licencia, visite http://creativecommons.org/licenses/by/4.0/






















