Applicability of the LSC technique for determining 210Pb in liquid samples for purposes of dose assessment via in vitro bioassay

Authors

  • Camilla da Silva Sampaio Lucena Instituto de Radioproteção e Dosimetria https://orcid.org/0000-0002-1692-1328
  • Geiza Celeste de Oliveira Medeiros
  • Sueli Alexandra Mesquita
  • Bernardo Maranhão Dantas
  • Wanderson Oliveira Sousa

DOI:

https://doi.org/10.15392/bjrs.v10i2.1742

Keywords:

in vitro bioassay, 210Pb, internal dosimetry

Abstract

A new approach for the determination of 210Pb by liquid scintillation counting was developed by the LBIOVT. In order to assess the applicability of the technique for internal monitoring of occupationally exposed workers and members of the public, some probable scenarios for the intake of 210Pb were elaborated and evaluated in this work. The methodology developed provides detection limit values suitable for detecting activities corresponding to committed effective doses below 1 mSv in a variety of scenarios. For members of the public, the time interval between the supposed intake and the collection of the sample could be up to 240 days for daily urine collection or up to 130 days for daily faeces collection. In a monitoring program for occupational exposed workers the methodology developed could be used in a monitoring interval twice an year both for daily urine or faeces collection and the detection limits would still be able to detect activities corresponding to a committed effective doses below the recording level. It is concluded that the methodology developed is suitable to be used for monitoring individual members of the public in case of an accidental exposure or to be used in a monitoring program for occupational exposed workers

Downloads

Download data is not yet available.

Author Biography

Camilla da Silva Sampaio Lucena, Instituto de Radioproteção e Dosimetria

Works as chemical technician in the in vitro Bioassay Laboratory (LBIOVT) from the Division of Dosimetry (DIDOS) of the Institute of Radioprotection and Dosimetri (IRD) in Brazil.

References

IAEA - International Atomic Energy Agency. Radiation Protection of the Public and the En-vironment, IAEA Safety Standards Series No. GSG-8, IAEA, Vienna (2018).

LAURIA, D. C., CARVALHO, L. L., CONTI, C. C. Comparison of different methods for 210Pb determination in environmental samples. Adv. Liq. Scintillation Spectrom. LSC 2005, 211–216, 2006.

SAMPAIO, C. S., MEDEIROS, G. C. O, MESQUITA, S. A., DANTAS, B. M., SOUSA, W. O. A new approach for the determination of 210Pb by liquid scintillation counting. Applied Ra-diation and Isotopes 156 (2020) 108972. DOI: https://doi.org/10.1016/j.apradiso.2019.108972

ICRP - International Commission on Radiation Units and Measurements. Basic Anatomical and Physiological Data for Use in Radiological Protection Reference Values. ICRP Publica-tion 89 (2002).

JULIÃO, L. M. Q. C., MELO, D. R., SOUSA, W. O., SANTOS, M. S., FERNANDES, P. C. P. Uncertainty on faecal analysis on dose assessment. Radiation Protection Dosimetry 127 (2007) 1-4 pp. 421-424 DOI: https://doi.org/10.1093/rpd/ncm481

ICRP - International Commission on Radiation Units and Measurements. Individual Monitor-ing for Internal Exposure of Workers (preface and glossary missing). ICRP Publication 78 (1997).

BERTELLI, L., MELO, D, R., LIPSZTEIN, J., CRUZ-SUAREZ, R. AIDE: Internal Dosime-try Software Radiation Protection Dosimetry, vol. 130, n. 3, pp. 358-367, 2008. DOI: https://doi.org/10.1093/rpd/ncn059

ICRP - International Commission on Radiation Units and Measurements. Compendium of Dose Coefficients based on ICRP Publication 60. ICRP Publication 119 (2012).

ICRP - International Commission on Radiation Units and Measurements. Dose Coefficients for Intakes of Radionuclides by Workers. ICRP Publication 68 (1994).

IAEA - International Atomic Energy Agency. Occupational Radiation Protection, IAEA Safety Standards Series No. GSG-7, Vienna (2018).

Downloads

Published

2022-06-13

How to Cite

Lucena, C. da S. S., Medeiros, G. C. de O., Mesquita, S. A., Dantas, B. M., & Sousa, W. O. (2022). Applicability of the LSC technique for determining 210Pb in liquid samples for purposes of dose assessment via in vitro bioassay. Brazilian Journal of Radiation Sciences, 10(2). https://doi.org/10.15392/bjrs.v10i2.1742

Issue

Section

Articles

Most read articles by the same author(s)

<< < 1 2