Computer Simulations Applied to Small-Field Dosimetry in Radiotherapy
DOI:
https://doi.org/10.15392/2319-0612.2022.1778Keywords:
MCNPX, Dosimetry, Small FieldsAbstract
With the advancement of radiotherapy techniques, we find some challenges in small field dosimetry that are widely used in head and neck treatments, so computer simulations with the Monte Carlo method, already well established in medical physics, are a great tool for studying small field dosimetry. The present work aims to report the validate of the geometry model used for the simulations of a 6 MV LINAC beam, in addition to estimating the TPS, PDD and PDD 20,10 curves for several regular and small fields, allowing comparisons with experimental data .
- Views: 152
- PDF Downloads: 149
Downloads
References
Andreo, P. Monte Carlo simulations in radiotherapy dosimetry. Radiat Oncol 13, 121 (2018). DOI: https://doi.org/10.1186/s13014-018-1065-3
D. Rogers, Fifty years of Monte Carlo simulations for medical physics. Physics in Medicine and Biology 51 R287-R301.(2006) DOI: https://doi.org/10.1088/0031-9155/51/13/R17
INTERNATIONAL ATOMIC ENERGY AGENCY, Dosimetry of Small Static Fields Used in External Beam Radiotherapy, Technical Reports Series No. 483, IAEA, Vienna (2017).
T. Fonseca, et al., “Simulação de um acelerador LINAC 6MV para determinação da dose de profundidade e razão tecido fantoma utilizando MCNPx e EGSnrc”. Brazilian Journal of Radiation Sciences. 4. 10.15392/bjrs.v4i2.201. (2016). DOI: https://doi.org/10.15392/bjrs.v4i2.201
L. Brualla, et al. PENELOPE/PRIMO-calculated photon and electron spectra from clinical accelerators. Radiat Oncol 14, 6 (2019). DOI: https://doi.org/10.1186/s13014-018-1186-8
A. Mesbahi ,et. al.. “A comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs”. J. Radiat. Res. 5. 23-3. (2007).
Pelowitz D, 2011 MCNPX User’s Manual Version 2.7.0 Los Alamos National Laboratory LA-CP- 11-00438 ed.(2011)
IAEA, TRS. 398. Absorbed dose determination in external beam radiotherapy: An International Code of Practice for Dosimetry based on standards of absorbed dose to water. Vienna International Atomic Energy Agency, (2000).
T. Fonseca, et al., MCMEG: Simulations of both PDD and TPD for 6 MV LINAC photon beam using different MC codes. Radiation Physics and Chemistry 140 386-391. (2017). DOI: https://doi.org/10.1016/j.radphyschem.2017.03.048
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/