Quality control in blood irradiation

Authors

  • F. Lopes Universidade Estadual de Londrina
  • R.C.G. Rocha Hemocentro - Hospital Universitário. Universidade Estadual de Londrina
  • E. Munhoz Hemocentro - Hospital Universitário. Universidade Estadual de Londrina
  • F.C. Trigo Hemocentro - Hospital Universitário. Universidade Estadual de Londrina
  • V.B.E.R. Feijó Hemocentro - Hospital Universitário. Universidade Estadual de Londrina
  • M. Fernandes Hemocentro - Hospital Universitário. Universidade Estadual de Londrina
  • De Paula T.C METROBRAS – Metrologia das Radiações Ionizantes
  • L.G. Padilha Filho Fundação Técnico Educacional Souza Marques.
  • G.S. Araujo Fundação Técnico Educacional Souza Marques

DOI:

https://doi.org/10.15392/2319-0612.2023.2183

Keywords:

Quality Control, calibration processes, radiation dose rate.

Abstract

Irradiation is a technique used in hemotherapy to functionally inactivateviable lymphocytes, in cellular blood components, to reduce the risk of Transfusion-associated Graft-versus-Host Disease (AT-GVHD), is rare but letal. One way to avoid it is to irradiate blood componentes in situations such as: intrauterine transfusion, newborns, patients receiving immunosuppressive therapy in bone marrow transplantation. Thus, it is extremely important that blood component is irradiated and, above all, ensure that the minimum dose is 25 Gy.The blood policy in Brazil is implemented through laws and normative decrees, giving rise to a legal system that underpins the actions of hemotherapy services. In order to correct verify absorbed doses and the quality assurance process as well as the safety for the irradiator operators we describe in this paper a several of physical measurements that is mandatory to support a physicist to evaluate the quality assurance during and after the irradiation process. The results obtained from this physical measurements  provided a guarantee of proper radiation dose used in hemotherapy as well as methods and procedures applied to protect the patient, employees and general public due to procedure of blood irradiation accordling the Technical Regulation of Hemotherapy Procedures of the National Health Surveillance Agency (ANVISA) and safety regulations by National Nuclear Energy Commission (CNEN).

Downloads

Download data is not yet available.

References

MINTZ, P.D.; WEHRLI, G. Irradiation erradication and pathogen reduction. ceasing cesium irradiation of blood products. Bone Marrow Transplantation, 44(4) p. 205-11, 2009.

UCHIDA S, TADOKORO K, TAKAHASHI M, YAHAGI, H, SATAKE M, JUJI . Analysis of 66 patients definitive with transfusion-associated graft-versus-host disease and the effect of universal irradiation of blood. Transfusion Medicine, 2013, vol. 23, 6 (pg. 416-422).

HEIKO RÜHL, GREGOR BEIN, ULRICH J.H. SACHS. Transfusion-associated graft-versus-host disease. Transfusion medicine . volume 23, issue 1, January 2009, pages 62-71

DWYRE D.M, HOLLAND PV. Transfusion-associated graft-versus-host disease. Vox Sang, 2008, vol. 95 2(pg. 85-93).

LEITMAN S.F. HOLLAND PV. Irradiation of blood products: indications and guidelines. Transfusion. 1985;25(4):293–303

BURAK BAHAR, CHRISTOPHER A. TORMEY . Prevention of Transfusion-Associated Graft-Versus-Host Disease With Blood Product Irradiation: The Past, Present, and Future. Arch Pathol Lab Med (2018) 142 (5): 662–667.

FLIEDNER V.V. HIGBY DJ. KIM U. Graft-versus-host reaction following blood product transfusion. Am J Med. 1982;72(6):951–961.

THALER; M. SHAMISS A. ORGAD S.ET AL. The role of blood from HLA-homozygous donors in fatal transfusion-associated graft-versus-host disease after open-heart surgery. N Engl J ed. 1989;321(1):25–28.

TAKAHASHI K. JUJI T.MIYAZAKI H. Post-transfusion graft-versus-host disease occurring in non-immunosuppressed patients in Japan. Transfusion Science 1991;12(4):281–289.

PETZ LD. CALHOUN L.YAM P. ET AL. Transfusion-associated graft-versus-host disease in immunocompetent patients: report of a fatal case associated with transfusion of blood from a second-degree relative, and a survey of predisposing factors. Transfusion. 1993;33(9):742–750.

Center for Disease Control and Prevention. National Healthcare Safety Network Biovigilance Component Hemovigilance Module Surveillance Protocol. http://www.cdc.gov/nhsn/PDFs/Biovigilance/BV-HV-protocol-current.pdf . Last accessed: April 12, 2023.

KENNETH C. ANDERSON, LAWRENCE T. GOODNOUGH, MERLIN SAYERS, PATRICIA T. PISCIOTTO, SANFORD R. KURTZ, THOMAS A. LANE, CAROL S. ANDERSON, AND LESLIE E. SILBERSTEIN. Variation in Blood Component Irradiation Practice: Implications for Prevention of Transfusion- Associated Graft-Versus-Host Disease. Blood, Vol77, No 10 (May 15). 1991: pp 2096-2102

AARON E. PRITCHARD, BETH H. SHAZ . Survey of irradiation practice for the prevention of transfusion-associated graft-versus-host disease. Arch Pathol Lab Med (2016) 140 (10): 1092–1097.

KAREN E. KING AND PAUL M. NESS. How do we prevent transfusion-associated graft- versus-host disease in children? TRANSFUSION Volume 51, May 2011

KOPOLOVIC, I.; OSTRO, J.; TSUBOTA, H.; YULIA LIN, Y.; CSERTI-GAZDEWICH. C. M.; MESSNER, H. A.; KEIR, A.K.; DENHOLLANDER,N. ; DZIK, W. S. CALLUM, J.. A systematic review of transfusion-associated graft-versus-host disease. Blood (2015) 126 (3): 406–414.

GÓES E.G., COVAS D.T., HADDAD R, ET AL. Quality control system for blood irradiation using a teletherapy unit. Vox Sang 2004, 86:105-10.

MORON, G.; LEITMAN, S.F., LUBAN, N.L.C., Principles of blood irradiation, dose valida-tion and quality control. Transfusion, Vol.37. p 1084-1091,1997.

KIM, H.J.; LEE, D.Y.; KYE, Y.U.; KIM, J.K.; JO, W.S.; KANG, Y.R. Preliminary results on the quality control of blood irradiators using an alanine/electron paramagnetic resonance dosimeter. Journal of Instrumentation, JINST 16 P07031, 2021.

Brazilian Health Regulatory Agency (ANVISA). Ordinance n. 158, Redefines the technical regulation of hemotherapeutic procedures. February 4, 2016. Available at: <https://bvsms.saude.gov.br/bvs/saudelegis/gm/2016/prt0158_04_02_2016.html. Last accessed: April 12, 2023.

Brazilian Health Regulatory Agency (ANVISA). Resolução RDC nº 34. Boas práticas no ciclo do sangue. 11 de junho de 2014.

GÓES E.G., BORGES J.C., COVAS D.T., et al. Quality control of blood irradiation: determination of cells radiosensitivity to cobalt-60 gamma rays. Transfusion. 2005.

GÓES E.G., NICOLUCCI P., NALI L.C. Study of the spatial distribution of the absorbed dose in blood volumes irradiated using a teletherapy unit. Radiation Physics and Chemistry 2010; 79:673-677.

GOES, E.G., OTTOBONI, M.A., PALMA, P.V.B., MORAIS, F.R., PELA, C.A.,BORGES, J.C., COVAS. D.T. Quality control of blood irradiation with a teletherapy unit: damage to stored red blood cells after cobalt-60 gamma irradiation. Transfusion. V. 48, issue 2. 2008.

DIRETRIZES BÁSICAS DE PROTEÇÃO RADIOLÓGICA - CNEN-NN 3.01, Resolução 164/14 – Março, 2014.

SERVIÇOS DE RADIOPROTEÇÃO CNEN-NE-3.02. Resolução CNEN 231/18, Setembro / 2018.

Troubleshooting Manual. Best Theratronics. Gammacell 1000 Elite/3000 Elan.

http://www.theratronics.ca/product_gamma.html. Last accessed: April 12, 2023.

IAEA- International Atomic Energy Agency. IAEA safety standards series no. SSR- 6 (rev.1) regulations for the safe transport of radioactive material. 2018 edition for specific safety requirements.

ANSI - American National Standards Institute. American National Standard n433.1; safe design and use of self-contained, dry source storage gamma irradiators (category I). (https://www.ansi.org). Last accessed: April 12, 2023.

ICRP - International Commission on Radiological Protection. (https://www.icrp.org/). Last accessed: April 12, 2023.

EBRAHIM FARAJZADEH ; SEDIGHEH SINA. Developing a radiochromic dosimeter for dosimetry in blood irradiation chambers. Radiation Physics and Chemistry. v.22-2021.

KHALED SOLIMAN ; MAROUF ADILI ; ABDULLAH ALRUSHOUD. Radiation dose verification of an X-ray based blood irradiator using EBT3 radiochromic films calibrated using Gamma Knife machine. Reports of Practical Oncology & Radiotherapy v. 7. 2019.

J.R. CHANDLER, SHOLOM, S., MCKEEVER, S.W.S., BAKHANOVA, E. CHUMAK, V., VEL ́ASQUEZ, D., HALL, H.L.Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations. Radiation Measurements.v. 6. 2022.

VANDANA, S., SHAIJU, V.S., SHARMA, S.D., MHATRE, S., SHINDE, S., CHOUR, G. Dosimetry of gamma chamber blood irradiator using gafchromic ebt. Applied radiation and isotopes. 69 (2011) 130–135.

SORCHA NI LOINGSIGH, WILLY A. FLEGEL, JEANNE E. HENDRICKSON, CHRISTOPHER A. TORMEY. Preventing transfusion-associated graft-versus-host disease with blood component irradiation: indispensable guidance for a deadly disorder. Transfusion. v. 61. 11. 2021.

METROBRAS – Metrologia das Radiações. (https://www.metrobras.com.br/). Last accessed April 12, 2023.

LUDLUMS - Measurements, INC. (https://ludlums.com/products/all-products/product/model-26-1-series). last accessed: april 12, 2023.

Downloads

Published

2023-06-06

How to Cite

Lopes, F., Rocha , R., Munhoz , E., Trigo, F., Feijó, V., Fernandes , M., De Paula, T., Padilha Filho, L., & Araujo, G. (2023). Quality control in blood irradiation. Brazilian Journal of Radiation Sciences, 11(1A (Suppl.), 01–17. https://doi.org/10.15392/2319-0612.2023.2183