A diffractometer project for Brazilian Multipurpose Reactor (RMB): McStas simulations and instrument optimization
DOI:
https://doi.org/10.15392/bjrs.v9i1A.1499Keywords:
diffractometer, McStas simulations, neutron fluxAbstract
High-resolution diffractometer is one of the first instruments of the set of 15 priority neutron scattering instruments to be installed at the Brazilian Multipurpose Reactor (RMB). A basic project of this instrument consists of the existence of three guides through which neutrons pass from source to sample to guarantee maximum neutron flux at the sample position. In this study, we investigate guide geometry performance considering fixed diffractometer geometry and spatial arrangement. Comparisons between different guide shapes and supermirrors are performed using software based on the Monte Carlo method, McStas. Our conclusion shows that a better solution is splitting the initial flux into two different guides to obtain the maximum flux at the sample position.- Views: 193
- PDF Downloads: 189
Downloads
References
PERROTTA, J. A.; SOARES, A. J.; GENEZINI, F. A.; SOUZA, F. A.; FRANCO, M. K. K. D.; and GRANADO, E., “Future perspectives for neutron beam utilization in Brazil” Neutron News, v. 25, p. 3-5, 2014.
LEFMANN, K. and NIELSEN, K., “Mcstas, a general software package for neutron ray-tracing simulations,” Neutron News, v. 10 (3), p. 20-23, 1999.
LISS, K.D.; HUNTER, B.; HAGEN, M.; NOAKES, T. and KENNEDY, S., “Echidna the new high-resolution powder diffractometer being built at opal,” Physica B: Condensed Matter, v. 385-386, p. 1010-1012, 2006.
AVDEEV, M. and HESTER, J.R., “ECHIDNA: a decade of high-resolution neutron powder diffraction at OPAL,” Journal of Applied Crystallography, v. 51, p. 1597-1604, 2018.
“Components and instruments from the library for McStas.” http://www.mcstas. org/download/components/. Accessed: 27/06/2019.
RIETVELD, H.M., “A profile refinement method for nuclear and magnetic structures,”
Journal of Applied Crystallography, v. 2, p. 65-71, 1969.
RIETVELD, H.M., “The rietveld method,” Physica Scripta, v. 89, p. 098002, 2014.
BUCHSTEINER, A. and STER, N., “Optimizations in angular dispersive neutron powder dif-fraction using divergent beam geometries,” Nuclear Instruments and Methods in Physics Re-search Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v. 598, p. 534-541, 2009.
HOELZEL, M.; SENYSHYN, A.; JUENKE, N.; BOYSEN, H.; SCHMAHL, W. and FUESS, H., “High- resolution neutron powder diffractometer SPODI at research reactor FRM II,” Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detec-tors and Associated Equipment, v. 667, p. 32-37, 2012.
VAN EIJCK, L.; CUSSEN, L.D.; SYKORA, G.J.; SCHOONEVELD, E.M.; RHODES, N.J.; VAN WELL, A.A. and PAPPAS, C., “Design and performance of a novel neutron powder diffractometer: PEARL at TU Delft,” Journal of Applied Crystallography, v. 49, p. 1398- 1401, 2016.
ZHANG, J.; XIA, Y.; ZHANG, Y.; PANG, B.; SUN, G.; LI, J.; HUANG, C.; WANG, Y.; PAN, J. and XIE, C., “Performance improvement of the high resolution neutron diffractometer at CAEP with geant4 simulation,” Journal of Instrumentation, v. 12, p. 10007, 2017.
CAGLIOTI, G.; PAOLETTI, A. and RICCI, F., “Choice of collimators for a crystal spec-trometer for neutron diffraction,” Nuclear Instruments, v. 3, p. 223-228, 1958.
COURTOIS, P., “Vertical neutron beam focusing with bent mosaic crystals,” Journal of Physics: Conference Series, v. 746, p. 012005, 2016.
HEWAT, A., “Design for a conventional high-resolution neutron powder diffractometer,”
Nuclear Instruments and Methods, v. 127, p. 361-370, 1975.
GILLES, R.; ARTUS, G.; SAROUN, J.; BOYSEN, H. and FUESS, H., “The new structure powder diffractometer at the FRM-II in garching,” Physica B: Condensed Matter, v. 276-278, p. 87-88, 2000.
LECHNER, R.; WALLPACH, R.V.; GRAF, H.; KASPER, F.J. and MOKRANI, L., “A monochromator with variable horizontal and vertical curvatures for focussing in real and reciprocal space,” Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spec-trometers, Detectors and Associated Equipment, v. 338, p. 65-70, 1994.
“The source_gen component.” http://www.mcstas.org/download/components/ sources/Source_gen.html. Accessed: 27/06/2019.
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/