Study of dosimetry in CT using head phantom

Authors

  • Mauricio Gomez Nuclear Egeenering Department - UFMG
  • Priscila do Carmo Santana Nuclear Egeenering Department - UFMG
  • Arnaldo Prata Mourão Nuclear Egeenering Department - UFMG Biomedical Engeenering Departemnt - CEFET

DOI:

https://doi.org/10.15392/bjrs.v7i1A.338

Keywords:

dosimetry, computed tomography, phantom

Abstract

Non-invasive diagnosis methods based on x-ray attenuation, such as Computed Tomography (CT) has had since its discovery and the development of this technology, a rapid growth in radiology services. The quantity of dose deposited in patients, is still large, this type of examination is that reaches the highest levels of absorbed dose in the population. Legislation that regulates the levels of patient’s dose is only limited to a maximum amount deposited, depending the body region to be irradiated.  Therefore, it is necessary to determine the amount of absorbed dose on patients depending on the protocols of routine used in radiology services for propose an optimization of these based on the principles of radiation protection. Experiments were conducted to determine the profile of dose deposited in head routine exams for adult, using a cylindrical head phantom made of polymethylmethacrylate (PMMA). This standard phantom has four openings in peripheral and one central. Radiochromic film strips were introduced into each one of these openings to register the longitudinal dose profile in each region to determine the amount of deposited dose in the volume of the head phantom. A CT scanner with 64 channels of GE from the radiology department was used for scanning the head phantom. The scanning were done with voltages of 80, 100 and 120 kV, and dose index found were between 6.24 and 23.73 mGy. Analysis of image quality was performed, finding that all scan comply with the parameters acceptable in diagnosis for Brazilian legislation. It is propose an optimized protocol for exams by CT head for the voltage of 80 kV and images with 0.5% of noise index.

Downloads

Download data is not yet available.

Author Biography

Mauricio Gomez, Nuclear Egeenering Department - UFMG

Departamento de engenharia nuclear - UFMG

References

ANDISCO, D.; BLANCO, S.; BUZZI, A. Dosimetría en tomografía computada. Revista Argen-tina de radiología, Elsevier, v. 78, n. 3, p. 156–160, 2014.

ANDRADE, M. E. A. Avaliação da qualidade de imagem e do índice volumétrico de kerma ar em tomografia computadorizada (cvol) em recife. Universidade Federal de Pernambuco, 2008.

AUGUSTO, F. M. Estudo da qualidade da imagem e índices de dose em tomografia computado-rizada. Tese (Doutorado) — Universidade Federal do Rio de Janeiro, 2009.

BEISTER, M.; KOLDITZ, D.; KALENDER, W. A. Iterative reconstruction methods in x-ray ct. Physica medica, Elsevier, v. 28, n. 2, p. 94–108, 2012.

CALZADO, A.; GELEIJNS, J. Tomografía computarizada. evolución, principios técnicos y aplicaciones. Revista de Física Médica, v. 11, n. 3, 2010.

DALMAZO, J. et al. Otimização da dose em exames de rotina em tomografía computadorizada: estudo de viabilidade em um hospital universitário. Radiologia Brasileira, Colégio Brasileiro de Radiologia e Diagnóstico por Imagem, v. 43, n. 4, p. 241–248, 2010.

DHAWAN, A. P. Medical Image Analysis. [S.l.]: IEEE, 2011. 88-93 p.

RADCAL, C. ACCU-GOLD User Guide. [S.l.], 2015.

TAWFIK, G. et al. Characteristics of gafchromic xrqa2 films for kv image dose measurement. Medical Physics, v. 39, n. 2, 2012.

National Institute of Standards and Technology. www.nist.gov, access January 30th. 2015.

Downloads

Published

2019-01-28

How to Cite

Gomez, M., do Carmo Santana, P., & Prata Mourão, A. (2019). Study of dosimetry in CT using head phantom. Brazilian Journal of Radiation Sciences, 7(1A (Suppl.). https://doi.org/10.15392/bjrs.v7i1A.338

Issue

Section

Simposio Internacional sobre Protección Radiológica en Medicina - Arequipa 2017

Similar Articles

<< < 1 2 3 > >> 

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)