Quality control of radiotherapy treatment plans with electrons
DOI:
https://doi.org/10.15392/bjrs.v7i1.785Keywords:
radiotherapy, Monte Carlo dosimetry, EGSnrc.Abstract
In this work the quality of the treatment planning generated by EclipseÒ commercial treatment planning system for electron beams of energy 9 and 20 MeV was verified and their accuracy in the calculation of dose distributions for several clinical situations was evaluated. Tests cases had been developed according to the Brazilian reality, having as reference the radiotherapy treatments carried out in the National Institute of the Cancer.The system developed for checking the quality of treatment planning systems with electrons was efficient in evaluating the Eclipse planning system by identifying the failures of their algorithms, especially in planning the isodose. The verification system has been validated against the Monte Carlo method and the experimental data with an ionization chamber and showed the shortcomings of generalized pencil beam and eMC algorithms.
- Views: 171
- PDF Downloads: 280
Downloads
References
HOSTROM, K.R.; ALMOND, P.R. Review of electron beam therapy physics. Phys. Med. Biol. 2006;51:R455-89.
OJALA, J.; KAPANEN, M.; HYÖDYNMA, S. Full Monte Carlo and measurement-based performance assessment of improved clinical implementation of eMC algorithm with emphasis on lower energy range. Physica Medica. 2016; (32) 801-811.
CHETTY, I.J; CURRAN,B.; CYGLER, J.; DEMARCO,J.J.; EZZELL, G.; FADDEGON, B.A. et al. Report AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based-photon and electron external beam treatment planning. Med Phys. 2007; 34:4818-53.
SHEIKH-BAGHERI, D.; KAWRAKOW,I.; WALTERS, B.; ROGERS,D.W.O. Monte Carlo simulations: Efficiency Improvement Techniques and Statistical Considerations, Published in: Integrating New Technologies into the Clinic: Monte Carlo and Image-Guided Radiation Therapy, Proceeding 2006 AAPM Summer School. Madison WI. Medical Physics Publishing; 2006.
JANSEN, J.J.; KOREVAAR, E.W.; VAN BUTTUM, L.J.; STORCHI, P.R.; HUIZENGA, H. A model to determine the initial phase space of a clinical electron electron beam from measured data. Phys. Med. Biol. 2001;46(2):269-86.
DING, G.X.; DUGGAN, D.M.; LU, B. et al. Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy. Med Phys 2007; 34:2985-94.
NEUENSCHWANDER, H., MACKIE,T.R.; RECKWERDT, P.J. MMC – a high performance Monte Carlo code for electron beam treatment planning. Phys Med Biol. 1995;40(4):543-74.
FRAGOSO, M.; PILLAI, S.; SOLBERG, T.D.; CHETTY, I.J. Experimental verification and clinical implementation of a commercial Monte carlo electron beam dose calculation algorithm. Med Phys. 2008; 35(3):1028-38.
NEUENSCHWANDER, H.; BORN, E.J. A macro Monte Carlo method for electron beam dose calculations. Phys Med Biol. 1992;37:107-25.
Eclipse Planning Reference Guide Algorithms P/N B401653R01I;2004.
DING, G.X.; DUGGAN, D.M.; COFFEY, C.W.; SHOKRANI, P.; CYGLER, J. First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning – new issues for clinical consideration. Phys. Med Biol. 2006;51:2781-99.
POPPLE, R.A; WEINBER, R.; ANTOLAK, J.A.; YE, D.J.; PAREEK, P.N.; DUAN, J. et al. Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a satandard verification data set. Med. Phys. 2006;33:1540-51.
FORTES, S.S. Algoritmo para o Cálculo de Feixes Clínicos de Elétrons eMC: Comissionamento e Avaliação, Trabalho de Conclusão de Curso, Instituto Nacional do Câncer, 2009.
User Manual VerisoftTM, PTW Freiburg, Germany, 2006.
ICRU (International Comission on Radiation Units and Measurements), Report 44, Tissue Substitutes in Radiation Dosimetry and Measurement, ICRU Publications, Washington DC, 1989.
ROGERS, D.W.O.; FADDEGON, B.A.; DING, G.; MA, C.M.; WE, J.; MACKIE, T.R. BEAM:a Monte Carlo simulate radiotherapy treatment units. Med. Phys. 1995, 22 503-524.
KAWRAKOW I, ROGERS DWO, WALTERS B. BEAMnrc User’s Manual. Technical Report PIRS-509, 2013. National Research Council of Canada, Ottawa, Canada.
KAWRAKOW,I.; ROGERS, D.W.O.; WALTERS, B. DOSXYZnrc Users Manual, Technical Report PIRS-794, 2005. National Research Council of Canada, Ottawa, Canada.
SEGO Z. Multiple-source models for the beams from an Elekta SL25 clinical accelerator. 2006. Master Thesis, Ottawa-Carleton Institute of Physics.
MCGOWAN, H.C.E.; FADDEGON, B.A.; MA C-M. STATDOSE for 3D distributions. PIRS-509(F), 2013. National Research Council of Canada, Ottawa, Canada.
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/