Evaluation of polybutadiene rubbers using FTIR spectra

Authors

  • Lucas N Oliveira
  • Fernando Schimidt
  • Silvio Leão Vieira
  • Patricia de Lara Antonio
  • Linda Viola Ehlin Caldas

DOI:

https://doi.org/10.15392/bjrs.v5i2.198

Keywords:

radiation, dosimetry, detectors

Abstract

Radiation dosimetry for medical and industrial purposes has increasingly evolved over the last few decades with the introduction of various new detectors. Depending on the properties exhibited for radiation dosimetry, some detectors present their applications in a specific area. From a physics point of view, an ideal dosimeter should be able to measure absorbed dose. In this work, synthetic materials based on polybutadiene rubbers (PBR) were proposed as a new class of radiation detectors. The influence of radiation dose on their properties has been investigated for application in radiation dosimetry. The rubber samples were exposed to absorbed doses from 10 Gy up to 250 Gy, using a 60Co Gamma Cell-220 system. Their responses were carried out with a Fourier Transform Infrared (FTIR) Spectrometer to investigate the presence of absorbance peaks. The results suggested the existence of a relationship between the absorbed doses and the absorbance peaks associated with stretching (1300-1200 cm-1), deformation (1450-1340 cm-1) and vibration (1500-1400 cm-1) processes in the material. 

Downloads

Download data is not yet available.

References

CHMIELEWSKI, A.G.; HAJI-SAEID, M.; AHMED, S.. Progress in radiation processing of polymers. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, v. 236, n. 1, p. 44-54, 2005.

MCKEEN, L.W. “Plastics used in medical devices," in Handbook of polymer applications in medicine and medical devices. Elsevier US, Philadelphia, 2014.

MANSHAIE, R.; KHORASANI, S.N.; VESHARE, S.J.; ABADCHI, M.R. Effect of electron beam irradiation on the properties of natural rubber (nr)/styrene butadiene rubber (sbr) blend. Radiation Physics and Chemistry, v. 80, n. 1, p. 100-106, 2011.

ABADCHI, M.R.; JALALI-ARANI, A. The use of gamma irradiation in preparation of polybutadiene rubber nanopowder; its effect on particle size, morphology and crosslink structure of the powder. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, v.320, n.1, p.1-5, 2014.

ABIONA, A.A.; OSINKOLU, A.G. Gamma-irradiation induced property modification of polypropylene. International Journal of Physical Sciences, v. 5, n.7, p.960-967, 2010.

INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA). Dosimetry for Radiation Pro-cessing. Viena, Austria. 2000.

OLIVEIRA, L.M.; ARAUJO, P.L.B.; ARAUJO, E.S. The effect of gamma radiation on mechanical properties of biodegradable polymers poly(3-hydroxybutyrate) and poly(3-hydroxybutyrate-co-3-hydroxyvalerate). Materials Research, v. 16, n.1, p. 195-203, 2013.

ZHANG, Y.; ZHAO, S.F.; LI, Y.T.; XIE, L.D.; SHENG, K.L. Radiation effect on styrene-butadiene-styrene copolymer. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, v. 266, n.1, p. 3431 3436, 2008.

LAL, J.; MARK, J.E. Advances in Elastomers and Rubber Elasticity. Springer US, New York. 1986.

PROKOF'EVA, N.I.; SHVARTSBERG, G.I.; SPERANTOVA, I.B. Calculation of the infra-red spectrum of 1,4-trans-polybutadiene. Journal of Applied Spectroscopy, v. 27, n.3, p. 1185-1188, 1977.

Downloads

Published

2017-07-19

How to Cite

Oliveira, L. N., Schimidt, F., Vieira, S. L., Antonio, P. de L., & Caldas, L. V. E. (2017). Evaluation of polybutadiene rubbers using FTIR spectra. Brazilian Journal of Radiation Sciences, 5(2). https://doi.org/10.15392/bjrs.v5i2.198

Issue

Section

Articles

Most read articles by the same author(s)