Volume fractions calculation of a biphasic system on cylindrical tube using gamma ray and MCNP6 code
DOI:
https://doi.org/10.15392/bjrs.v9i1A.1388Keywords:
volume fraction, MCNP6 code, ray gammaAbstract
Be determined which is the volumetric fraction. This paper presents a methodology to calculate volumetric fractions on the stratified flow regime, considering a cylindrical tube. A mathematical model of a measurement system was developed using the MCNP6 code. The mathematical equation was developed to calculate the volume fractions using the pulse height distributions obtained by a radiation detector. The stratified flow regime model considers air-oil, air-gasoline and oil-gasoline biphasic flow, in order to evaluate the performance of the proposed equation in fluid combinations with different densities. A comparative study with equations developed for square-section tubes from literature was performed. The study considered geometry of a source of 137Cs, an acrylic tubing measuring 8.0 cm in diameter and a 1¼ × ¾" NaI(T1) detector placed at a position diametrically opposed to a radiation source to measure the transmitted beam. The dimensions and materials to perform the simulation of the detectors were based on information obtained from the gammagraphy technique and the detector was experimentally validated. The volume fractions of each of the fluids were 0 up to 100% with variations of 25%.
Downloads
References
M. S. A. Abouelwafa e E. J. M Kendall, “The measurement of component ratios in multiphase systems using gamma-ray attenuation”, Journal of Physics E: Scientific Instruments, 13, pp. 341-345 (1980).
Y. Mi, M. Ishii, e L. H. Tsoukalas, “Vertical two-phase flow identification using advanced instrumentation and neural networks”, Nuclear Engineering and Design, 184, pp.n409-420 (1998).
C. M. Salgado, L. E. B. Brandão, C. M. N. A. Nascimento, R. Schirru, R. Ramos e A. X. Silva, “Prediction of volume fractions in three-phase flows using nuclear technique and artificial neural network”, Applied Radiation and Isotopes, 67, pp. 1812-1818 (2009).
C. M. Salgado, C. M. N. A. Pereira, R. Schirru e L. E. B. Brandão, “Flow regime identification and volume fraction prediction in multiphase flows by means of gamma-ray attenuation and artificial neural networks”. Progress in Nuclear Energy, Vol. 52(6), pp. 555-562 (2010).
M. Khorsandi e S. A. H. Feghhi, “Design and construction of a prototype gamma-ray densitometer for petroleum products monitoring applications”. Measurement, 44, pp. 1512-1515 (2011).
A. A. Abdulrahman, E. M. Shokir, “Artificial neural networks modeling for hydrocarbon gas viscosity and density estimation”. Journal of King Saud University – Engineering Sciences, 23, pp. 123-129 (2011).
C. M. Salgado, L. E. B. Brandao, C. C. Conti e W. L. Salgado, “Density prediction for petroleum and derivatives by gamma-ray attenuation and artificial neural networks”, Applied Radiationand Isotopes, 116, pp. 143-149 (2016).
D. B. Pelowitz, A. J. Fallgren and G. E. Mc Math, “MCNP6TM User’s Manual Code Version 6.1.1 beta,” Los Alamos National Laboratory Report: LA-CP-14-00745, Los Alamos, NM (2014).
Salgado, C. M., Brandão L. E., Schirru R., Pereira C. M. N. A. E Ramos R., Silva A. X., 2008. “Modelagem de detector NaI(Tl) usando MCNP-X”, XI Encontro de Modelagem Computacio-nal, n. 0189, Volta Redonda, RJ.
C. M. Salgado, L. E. B. Brandão, C. M. N. A. Pereira, R. Ramos, R. Schirru e A. X. Silva, "Validation of a NaI(Tl) detector’s model developed with MCNP-X code". Progress in Nuclear Energy 59, pp.19-25 (2012).
Berger, M. J. e Seltzer, S.M. (1972), “Response functions for sodium iodide scintillation detectors”, Nuclear Instruments and Methods, 104, 317-332.
Saito, K. e Moriuchi, S., (1981). “Monte Carlo Calculation of accurate response functions for a NaI(Tl) detector for gamma rays”. Nuclear Instruments and Methods, 185, 299-308.
Orion, I. e Wilopolski, L. (2002), “Limitations in the PHOTON Monte Carlo gamma transport code”. Nuclear Instruments and Methods in Physics Research. A 480, 729-733.
Shi, Hu-Xia, Chen, Bo-Xian, Li Ti-Zhu, Yun, D.I. (2002), “Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector”, Applied Radiation and Isotopes, 57, 517-524.
Sood, A., Gardner, R. P. (2004), “A new Monte Carlo assisted approach to detector response functions”, Nuclear Instruments Methods Physics Research. B213, 100-104.
Ewa, I.O.B., Bodizs, D., Czifrus, S.Z. e Molnar, Z.S. (2001), “Monte Carlo determination of full energy peak efficiency for a HPGe detector”, Nuclear Instruments and methods in Physics Research, A 479, pp. 618-630.
Nakamura, T. (1983), “Monte Carlo Calculation of Peak Efficiencies of Ge(Li) and Pure Ge Detectors to Volumial Sources and Comparison with Environmental Radioactivity Measurement”, Nuclear Instruments and Methods, 205, pp. 211-218.
Sima, O. (1990), “Monte Carlo Simulation versus Semiempirical Calculation of Autoabsorption Factors for Semiconductor Detector Calibration in Complex Geometries”, Progress in Nuclear Energy, v. 24, pp. 327-336, UK.
Conti C.C. (1999), Medida de KERMA no ar e determinação de coeficientes de conversão para dose devido à radiação gama ambiental, Tese de doutorado. COPPE/UFRJ, Rio de Janeiro, Brasil.
Conti, C.C., Sachet, I.A., Bertelli, L. e Lopes, R.T. (1999), “Ge detectors calibration procedure at IRD/CNEN for in situ measurements”, in II International symposium on tecnologically enhanced natural radiation, Rio de Janeiro.
Salgado, C. M., Brandão, L. E., Schirru, R., Pereira, C. M., & Conti, C. C. (2012). Validation of a NaI(Tl) detector’s model developed with MCNP-X code. Progress in Nuclear Energy, 59, pp. 19-25.
Salgado, W. L., Dam, R. S. F., Barbosa, C. M., Silva, A. X., Salgado, C. M. (2020), “Monitor-ing system of oil by-products interface in pipelines using the gamma radiation attenuation”, Ap-plied Radiation and Isotopes, v. 160.
Published
Issue
Section
License
Copyright (c) 2021 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/