Efficiency stability of HPGe detectors under distinct count rates
DOI:
https://doi.org/10.15392/bjrs.v9i1A.1410Keywords:
HPGe, efficiency stability, pile upAbstract
In this work the reproducibility of the efficiency of different HPGe detectors was analyzed under a series of different conditions. The detectors studied were plugged either to a regular analogical amplifier or to a digital signal processing (DSP) device, in order to evaluate the possible differences between either setup. Detectors were inspected by performing a long series of sequential measurements with standard calibration sources, and comparing the standard deviation of the number of counts per second in each series to the uncertainty of the individual measurements. Detectors were also subjected to distinct count rates, in order to verify the possible experimental issues associated with this parameter. The results allow a discussion on the stability of the detectors’ efficiencies over a few days, the possible dependence with the count rate, and the estimation of the uncertainty related to the efficiency variation.
Downloads
References
ZAHN, G. S. ; TICIANELLI, R. B. ; LANGE, C. N. ; FAVARO, D. I. T. ; FIGUEIREDO, A. M. G. Uncertainty Analysis In Comparative NAA Applied To Geological And Biological Matrices, In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, 2015, São Paulo, Annals… São Paulo, Comissão Nacional de Energia Nuclear, 2015.
LOVELAND, W. D. ; MORRISSEY, D. J. ;SEABORG, G. T., Modern Nuclear Chemistry, Hoboken : John Wiley & Sons, 2006.
SIEGERT, H; SCHRADER, H. ;SCHÖTZIG, U. Half-life measurements of Europium radionuclides and the long-term stability of detectors, Appl Radiat Isot, v.49, p. 1397–1401,1998.
ALVES, A. P. ; AMARAL, A. M., KASTNER, G. F. ;FERREIRA, A. V. HPGe Gamma Detector:Efficiency Curve Evaluationduring Ten Years Of Operation, In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, 2009, Rio de Janeiro, Annals… Rio de Janeiro, Comissão Nacional de Energia Nuclear, 2009.
ZAHN , G. S. ; GENEZINI, F. A. ; TICIANELLI, R. B. ; SAIKI, M. Long-term performance assessment of HPGE detectors used in the neutron activation analysis laboratory of IPEN-CNEN/SP (Brazil), Appl Radiat Isot, v125, p. 108–112,2017.
Published
Issue
Section
License
Copyright (c) 2021 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/