Monte Carlo Characterization of an Individual Albedo Neutron Monitor

Authors

  • Rosane Moreira Ribeiro Instituto de Radioproteção e Dosimetria
  • Denison Souza-Santos Instituto de Radioproteção e Dosimetria

DOI:

https://doi.org/10.15392/bjrs.v9i2C.1657

Keywords:

Geant4, radiation protection, albedo dosimeter

Abstract

An individual albedo neutron dosimeter is simulated with the Geant4 toolkit. The simulation results are compared with results from an international intercomparison for Monte Carlo codes. The doses are obtained for thermoluminescent dosimeters irradiated free in the air and also on the surface of a water phantom for different neutron energy values. The Geant4 toolkit was not used by any of the participants in this intercomparison, so with these results we can infer the applicability of Geant4 in radiation protection for this type of simulation in neutron fields.

Downloads

Download data is not yet available.

References

ICRP - International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. ICRP Publication 103, Oxford, Pergamon Press, 2007.

ISO - International Organization for Standardization. Radiological protection – X and gamma reference radiation for calibratig dosemeters and doserate meters and for determining their response as a function of photon energy – Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence, ISO 4037-3, 2019.

TANNER, R. J. Neutron and photon response of a TLD-albedo personal dosemeter on an ISO slab phantom, QUADOS problem description P4. 2002, Available at: <http://www.nea.fr/download/quados/quados.html>. Last accessed: 4 Sept. 2020.

GEANT4 – A Simulation Toolkit. Software Download Archive: Geant4 10.5 Software Download, 2019. Available at:< https://geant4.web.cern.ch/support/download_archive?page=1> Last accessed: 17 Apr. 2019.

RIBEIRO, R.M., SOUZA-SANTOS, D. Comparison of the neutron ambient dose equivalent and ambient dose absorbed dose calculations with different Geant4 physics lists. Radiation Physics and Chemistry, v. 139, p. 179 – 183, 2017.

FURUTA, Y., TANAKA, S. Response of 6LiF and 7LiF thermoluminescence dosimeters to fast neutrons. Nuclear Instruments and Methods, v. 104, p. 36 –374, 1972.

CAMMI, A.; GARLATI, L. Neutron and/or photon response of a TLD-Albedo personal dosimeter on an ISO slab phantom. In: Intercomparison on the usage of computational codes in radiation dosimetry, 2003, Bologna, Italy. QUADOS. p.189–192. ISBN:88-8286-114-7

FREITAS, B. M. Simulação monte carlo da resposta de um monitor individual de nêutrons tipo albedo. 79 f. Tese (Doutorado) - Curso de Engenharia Nuclear, Coppe, UFRJ, Rio de Janeiro, 2018.

Published

2021-08-08

Issue

Section

Congresso Brasileiro de Metrologia das Radiações Ionizantes - CBMRI 2020

How to Cite

Monte Carlo Characterization of an Individual Albedo Neutron Monitor. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 9, n. 2C (Suppl.), 2021. DOI: 10.15392/bjrs.v9i2C.1657. Disponível em: https://bjrs.org.br/revista/index.php/REVISTA/article/view/1657.. Acesso em: 19 may. 2024.

Similar Articles

1-10 of 428

You may also start an advanced similarity search for this article.