Passive Autocatalytic Recombiner Perfomance Assessment Using COCOSYS

Authors

  • hugo pontes Instituto de Pesquisas Energéticas (IPEN)
  • gil teixeira
  • julian shorto
  • Alfredo abe
  • Cláudia Giovedi

DOI:

https://doi.org/10.15392/2319-0612.2022.1906

Keywords:

Hydrogen, Passive Autocatalytic Recombiners, THAI test facility, Severe Accidents.

Abstract

The progression of a severe accident in nuclear reactors is composed by a diversity of phenomena that are
Beyond Design Basis, such as Direct Containment Heating (DCH), Molten Corium Concrete Interaction
(MCCI), hydrogen detonation, and others. Currently, there are several devices and systems that allow
mitigating the progression of this events, avoiding the failure of the physical barriers between the nuclear
power plant and the environmental. In this context, the present work aims to reproduce the HR-14
experiment carried out at the Thermal-hydraulic, Hydrogen, Aerosols and Iodine (THAI) test facility through
the Passive Autocatalytic Recombiners (PAR) performance assessment with the COCOSYS code. The analysis
of the convergence of the results was performed using the Fast Fourier Transform Based Method (FFTBM)
and showed that the results had sufficient accuracy with the experimental data.

Downloads

Download data is not yet available.

References

Comissão Nacional de Energia Nuclear (CNEN), Relatórios de Operação de Usinas

Nucleoelétricas, Norma CNEN NN 1.14, Resolução CNEN 16/0, Publicação: DOU

01.2002.

Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Didier Jacquemain Coordinator,

Nuclear Power Reactor Core Melt Accidents, Current State of Knowledge, 2015.

International Atomic Energy Agency (IAEA), TECDOC-1661-Mitigation of Hydrogen

Hazards in Severe Accidents, 2011.

Gesellshaft für Anlagen- und Reaktorsicherheit (GRS) mbH, COCOSYS V2.4, User’s Manual.

Revision, 2016.

Kanzleiter, T., Hydrogen Recombiner Tests HR-14 to HR-16 (Tests using a nis par), Areva,

AECL and NIS PAR Comparison. Tech. Rep. 150 1326-HR-QLR-4, Becker Technologies

GmbH, 2009.

BECKER TECHNOLOGIESTHAI- Facility & Program Reactor Safety • Engineering

Becker Technologies GmbH – Kolner Str. 6 – 65760 Eschborn.

Jsehwan Park, Gilbeom Kang, Yu Jung Choi, Development and Validation of the Passive

Autocatalytic Recombiner Performance Analysis, 26TF International Conference Nuclear

Energy for new Europe (2017).

Miroslav Kotouč. Nuclear Research Institute, Validation of the LP Code MELCOR 1.8.6 for

Containment Analyses with Hydrogen Recombiners using results from the OECD/NEA

experimental project THAI ASME 2012 Power Conference ICONE20-POWER2012-54240.

F. Arnould, E. Bachellerie, M. Auglaire, B. De Boeck, O. Braillard, B. Eckardt, F. Ferroni, R.

Moffett, G. Van Goethem. State of the Art on Hydrogen Passive Autocatalytic Recombiner.

European Union Parsoar Project.

A. Proek, F. D’Auria, B. Mavko, Review of quantitative accuracy assessments with fast

Fourier transform based method (FFTBM), Nuclear Engineering and Design 217 (2002)

–206.

Lapendes, D.N., 1978. Dictionary of Scientific and Technical Terms, second ed.

McGraw-Hill Book Company, NewYork, St. Louis, p. 1041.

Bovalini, R., D’Auria, F., Leonardi, M., 1992. Qualification of the Fast Fourier

Transform based methodology for the quantification of thermalhydraulic code accuracy,

DCMN Report, University of Pisa, NT 194(92).

Official Scilab site: https://www.scilab.org/news/scilab-600-release.

A. Prosek, B. Mavko, A tool for quantitative assessment of code calculations with an

improved fast Fourier transform based method, Jamova 39, 1000 Ljubljana, Slovenia.

Heikki Purhonen, Markku Puustinen, Vesa Riikonen, Riitta Kyrki-Rajama¨ki, Juhani

Vihavainen PACTEL integral test facility – Description of versatile applications. Lappeenranta

University of Technology, P.O. Box 20, 53851 Lappeenranta, Finland Received 25 April 2004;

accepted 31 May 2006.

Gesellshaft für Anlagen - und Reaktorsicherheit (GRS) mbH. Weiterentwicklung der

Rechenprogramme COCOSYS und ASTEC Oktober, 2014

Downloads

Published

2022-10-29

Issue

Section

INAC 2021_XXII ENFIR_VII_ENIN

How to Cite

Passive Autocatalytic Recombiner Perfomance Assessment Using COCOSYS. Brazilian Journal of Radiation Sciences, Rio de Janeiro, Brazil, v. 10, n. 3A (Suppl.), 2022. DOI: 10.15392/2319-0612.2022.1906. Disponível em: https://bjrs.org.br/revista/index.php/REVISTA/article/view/1906.. Acesso em: 7 nov. 2024.

Similar Articles

1-10 of 243

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)